Mohammad O. Hamdan

Dr. Mohammad O. Hamdan

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
AEAbdelrahman S. Emam
Abdelrahman S. Emam
MHMohammad O. Hamdan
Mohammad O. Hamdan
BABassam A. Abu-Nabah
Bassam A. Abu-Nabah
EEEmad Elnajjar
Emad Elnajjar

1 July 2024 in International Journal of Thermofluids
Verified
Journal Article
Open access
YSYahya Sheikh
Yahya Sheikh
MJMuhammad Jasim
Muhammad Jasim
MQMuhammad Qasim
Muhammad Qasim
AQAlaa Qaisieh
Alaa Qaisieh
MHMohammad O. Hamdan
Mohammad O. Hamdan
FAFarid Abed
Farid Abed

1 March 2001 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
MAM.K Alkam
M.K Alkam
MAM.A Al-Nimr
M.A Al-Nimr
MHMohammad O. Hamdan
Mohammad O. Hamdan

1 October 2011 in Renewable Energy
Verified
Journal Article
Closed access
MHMohammad O. Hamdan
Mohammad O. Hamdan

1 October 2015 in Renewable Energy
Verified
Journal Article
Closed access
MHMohammad O. Hamdan
Mohammad O. Hamdan
MSMohamed Younes Selim
Mohamed Younes Selim
SAShrideh Al-Omari
Shrideh Al-Omari
EEEmad Elnajjar
Emad Elnajjar

26 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AEAhmed Elsheikh
Ahmed Elsheikh
Bassam Abu-NabahBassam Abu-Nabah
Bassam Abu-Nabah
MHMohammad O. Hamdan
Mohammad O. Hamdan
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian
Different infrared (IR) planar geometric calibration targets have been developed over the years that exploit a well-established and flexible optical camera geometric calibration procedure following the pinhole approximation. This geometric calibration is typically neglected in IR cameras, due to the relatively low resolution of thermal images and the complex IR targets needed for the geometric calibration in comparison to the optical targets. In this study, a thorough literature review of numerous IR camera geometric calibration targets, along with their respective outcomes, were summarized and leveraged to deliver a practical checkerboard target for less experienced end users, while offering the lowest reprojection errors. It was concluded that the fabrication of high emissivity contrast and precise square points of intersection within a checkerboard pattern extends the accuracy of capturing these control points in a thermal image for an optimized IR camera geometric calibration. Accordingly, two simple planar checkerboard targets were fabricated using laser engraving and ultraviolet (UV) printing technologies on a polished stainless steel (SS304) plate. The UV-printed checkerboard target on a polished metallic alloy delivered the lowest mean reprojection error (MRE) of 0.057 pixels and the lowest root mean square error (RMSE) of reprojection of 0.063 pixels, with a standard deviation lower than 0.003 pixels. The UV-printed design offers better accuracy than any other checkerboard calibration target, and comparable results to the best prominent circular pattern results reported in the literature.