Ilhan Kocar

Prof. Ilhan Kocar

Polytechnique Montreal
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AHAboutaleb Haddadi
Aboutaleb Haddadi
MZMingxuan Zhao
Mingxuan Zhao
Ilhan KocarIlhan Kocar
Ilhan Kocar
UKUlas Karaagac
Ulas Karaagac
KCKa Wing Chan
Ka Wing Chan
EFEvangelos Farantatos
Evangelos Farantatos
Inverter-Based Resources (IBRs), including Wind turbine generators (WTGs), exhibit substantially different negative-sequence fault current characteristics compared to synchronous generators (SGs). These differences may cause misoperation of customary negative-sequence-based protective elements set under the assumption of a conventional SG dominated power system. The amplitude of the negative-sequence fault current of a WTG is smaller than that of an SG. This may lead to misoperation of the negative-sequence overcurrent elements 50Q/51Q. Moreover, the angular relation of the negative-sequence current and voltage is different under WTGs, which may result in the misoperation of directional negative-sequence overcurrent element 67Q. This paper first studies the key differences between the WTGs and SG by comparing their equivalent negative-sequence impedances with SG's. Then, simulation case studies are presented showing the misoperation of 50Q and 67Q due to wind generation and the corresponding impact on communication-assisted protection and fault identification scheme (FID). The impact on directional element is also experimentally validated in a hardware-in-the-loop real-time simulation set up using a physical relay. Finally, the paper studies the impact of various factors such as WTG type (Type-III/Type-IV) and Type-IV WTG control scheme (coupled/decoupled sequence) to determine the key features that need to be considered in practical protection studies. The objective is to show potential protection misoperation issues, identify the cause, and propose potential solutions.

17 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
AHAboutaleb Haddadi
Aboutaleb Haddadi
EFEvangelos Farantatos
Evangelos Farantatos
Ilhan KocarIlhan Kocar
Ilhan Kocar
UKUlas Karaagac
Ulas Karaagac
Inverter-based resources (IBRs) exhibit different short-circuit characteristics compared to traditional synchronous generators (SGs). Hence, increased uptake of IBRs in the power system is expected to impact the performance of traditional protective relay schemes—set under the assumption of a SG-dominated power system. Protection engineers need to study these challenges and develop remedial solutions ensuring the effectiveness of system protection under higher levels of IBRs. To address this need, this paper studies the impact of IBRs on a variety of protective relay schemes including line distance protection, memory-polarized zero sequence directional protective relay element, negative sequence quantities-based protection, line current differential protection, phase comparison protection, rate-of-change-of-frequency, and power swing detection. For each protection function, potential misoperation scenarios are identified, and recommendations are provided to address the misoperation issue. The objective is to provide an improved understanding of the way IBRs may negatively impact the performance of traditional protection schemes as a first step towards developing future remedial solutions ensuring effective protection under high share of IBRs.

1 April 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TKThomas Kauffmann
Thomas Kauffmann
UKUlas Karaagac
Ulas Karaagac
Ilhan KocarIlhan Kocar
Ilhan Kocar
SJSimon Jensen
Simon Jensen
EFEvangelos Farantatos
Evangelos Farantatos
JMJean Mahseredjian
Jean Mahseredjian
The power system planning and protection studies are becoming more challenging due to the rapid increase in penetration levels of converter-interfaced renewables. Type-IV wind turbine generators (WTGs) and photovoltaic panels (PVs) are interfaced to the grid through a full-scale converter (FSC), and their short-circuit current contributions are mainly designated by the converter control and associated current limits. This paper proposes a new phasor domain modeling approach for the wind parks (WPs) with Type-IV WTGs using the concept of control-based equivalent circuits. The proposed model precisely represents the detailed electromagnetic transient type (EMT-type) model in steady state and is able to account for the fault-ride-through (FRT) function of the WTG control as well as its specific decoupled sequence control scheme in addition to the traditional coupled control scheme. Although the collector grid and WTGs inside the WP are represented with their aggregated models, the overall reactive power control structure of the WP is preserved by taking the central wind park controller (WPC) into account. The accuracy of the proposed model is validated through detailed EMT simulations.

8 October 2013 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Ilhan KocarIlhan Kocar
Ilhan Kocar
JMJean Mahseredjian
Jean Mahseredjian
UKUlas Karaagac
Ulas Karaagac
GSGurkan Soykan
Gurkan Soykan
OSOmar Saad
Omar Saad
The unbalanced nature of distribution systems requires a multiphase load-flow solution capable of handling arbitrary network topologies and providing accurate results. The need for detailed analysis of secondary grid systems found in dense urban areas and the modeling of distribution networks including the subtransmission level requires using highly efficient and large-scale system-capable methods. In this paper, three different load-flow solution algorithms are presented using the modified-augmented-nodal-analysis formulation. The load-flow solution algorithms are compared for the IEEE 8500-node distribution test feeder using a proposed regulator tap control strategy.

12 July 2019 in IEEE Power and Energy Technology Systems Journal
Verified
Journal Article
Open access
UKU. Karaagac
U. Karaagac
JMJ. Mahseredjian
J. Mahseredjian
RGR. Gagnon
R. Gagnon
HGH. Gras
H. Gras
HSH. Saad
H. Saad
LWL. Wang
L. Wang
Utilities are under considerable pressure to increase the share of wind energy resources in their generation fleet. With the increasing share of wind energy resources, the dynamic behavior of power systems will change considerably due to fundamental differences in technologies used for wind and conventional generators. There is very little standardization in the ways to model wind turbines (WTs) and wind parks (WPs) in sharp contrast to conventional power plants. Hence, there is an international interest to deliver generic models (i.e. standardized and publicly available) for WTs and WPs that are able to capture all performance aspects as good as manufacturer-specific models. This paper presents an electromagnetic transient (EMT) simulation model for full size converter (FSC) WT based WPs that can be used for stability analysis and interconnection studies. The considered topology uses permanent magnet synchronous generator. Although the collector grid and the FSC WTs are represented with their aggregated models, the overall control structure of the WP is preserved. FSC WT and WP control systems include the non-linearities, and necessary transient and protection functions to simulate the accurate transient behavior of WPs.

30 January 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AHAboutaleb Haddadi
Aboutaleb Haddadi
Ilhan KocarIlhan Kocar
Ilhan Kocar
UKUlas Karaagac
Ulas Karaagac
HGHenry Gras
Henry Gras
EFEvangelos Farantatos
Evangelos Farantatos
Large-scale integration of wind generation changes the power swing characteristics of a power system and may result in misoperation of legacy power swing protection schemes. This paper presents a qualitative study on the impact of wind generation on power swing protection. The objective is to provide an understanding of the problem through case studies and present possible solutions and adjustments in protection schemes to ensure the efficiency of protection under large-scale integration of wind generation. The misoperation of power swing protection functions, namely Power Swing Blocking (PSB) and Out-of-Step Tripping (OST), as a result of increased wind generation levels, are shown through case studies. It is also shown that the electrical center of a power system may move due to wind generation. In this case, it would be necessary to revise the optimal location of the OST protection. Finally, the impact of various factors such as wind generator type, control scheme and Fault-Ride-Through (FRT) function, and wind generation level and capacity are investigated to determine the key features that need to be accounted for in practical protection studies