Jean Mahseredjian

Jean Mahseredjian

Auto-generated profile, based on publicly available information

Jean Mahseredjian

Polytechnique Montreal

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2022 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YCYunzhi Cheng
Yunzhi Cheng
LFLingling Fan
Lingling Fan
JRJonathan Rose
Jonathan Rose
SHShun-Hsien Huang
Shun-Hsien Huang
JSJohn Schmall
John Schmall
JZJenny Zhou
Jenny Zhou
This paper presents a survey of real-world subsynchronous oscillation events associated with inverter-based resources (IBR) over the past decade. The focus is on those oscillations in the subsynchronous frequency range known to be influenced by power grid characteristics, e.g., series compensation or low system strength. A brief overview of the historical events is presented followed by detailed descriptions of a series of events. This paper also examines causation mechanisms and proposes future research directions to meet grid needs worldwide.

1 April 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TKThomas Kauffmann
Thomas Kauffmann
UKUlas Karaagac
Ulas Karaagac
Ilhan KocarIlhan Kocar
Ilhan Kocar
SJSimon Jensen
Simon Jensen
EFEvangelos Farantatos
Evangelos Farantatos
JMJean Mahseredjian
Jean Mahseredjian
The power system planning and protection studies are becoming more challenging due to the rapid increase in penetration levels of converter-interfaced renewables. Type-IV wind turbine generators (WTGs) and photovoltaic panels (PVs) are interfaced to the grid through a full-scale converter (FSC), and their short-circuit current contributions are mainly designated by the converter control and associated current limits. This paper proposes a new phasor domain modeling approach for the wind parks (WPs) with Type-IV WTGs using the concept of control-based equivalent circuits. The proposed model precisely represents the detailed electromagnetic transient type (EMT-type) model in steady state and is able to account for the fault-ride-through (FRT) function of the WTG control as well as its specific decoupled sequence control scheme in addition to the traditional coupled control scheme. Although the collector grid and WTGs inside the WP are represented with their aggregated models, the overall reactive power control structure of the WP is preserved by taking the central wind park controller (WPC) into account. The accuracy of the proposed model is validated through detailed EMT simulations.

16 February 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MGMohsen Ghafouri
Mohsen Ghafouri
UKUlas Karaagac
Ulas Karaagac
Houshang KarimiHoushang Karimi
Houshang Karimi
SJSimon Jensen
Simon Jensen
JMJean Mahseredjian
Jean Mahseredjian
SFSherif O. Faried
Sherif O. Faried
This paper presents a linear-quadratic regulator (LQR) for damping of subsynchronous interaction (SSI) in doubly-fed induction generator (DFIG)-based wind farms. The proposed LQR controller employs a full-state observer to estimate all state variables. The output of the LQR is added to control signals of inner current control loops of DFIG converters as supplementary control signals. The supplementary control signals are dynamically limited to avoid saturating the converters and to provide the DFIG with the desired transient response against power system faults. The proposed SSI damping controller is designed for a realistic series compensated wind farm, and its performance is verified using electromagnetic transient (EMT) simulations. The EMT simulations are performed using a detailed DFIG model which includes all nonlinearities and all required transient functions to meet the grid code requirements corresponding to fault-ride-through (FRT). The results show that the proposed SSI controller is able to significantly mitigate the oscillations due to the SSI phenomenon, and to provide excellent transient response against systems faults.

12 July 2019 in IEEE Power and Energy Technology Systems Journal
Verified
Journal Article
Open access
UKU. Karaagac
U. Karaagac
JMJ. Mahseredjian
J. Mahseredjian
RGR. Gagnon
R. Gagnon
HGH. Gras
H. Gras
HSH. Saad
H. Saad
LWL. Wang
L. Wang
Utilities are under considerable pressure to increase the share of wind energy resources in their generation fleet. With the increasing share of wind energy resources, the dynamic behavior of power systems will change considerably due to fundamental differences in technologies used for wind and conventional generators. There is very little standardization in the ways to model wind turbines (WTs) and wind parks (WPs) in sharp contrast to conventional power plants. Hence, there is an international interest to deliver generic models (i.e. standardized and publicly available) for WTs and WPs that are able to capture all performance aspects as good as manufacturer-specific models. This paper presents an electromagnetic transient (EMT) simulation model for full size converter (FSC) WT based WPs that can be used for stability analysis and interconnection studies. The considered topology uses permanent magnet synchronous generator. Although the collector grid and the FSC WTs are represented with their aggregated models, the overall control structure of the WP is preserved. FSC WT and WP control systems include the non-linearities, and necessary transient and protection functions to simulate the accurate transient behavior of WPs.

23 January 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HXHaoyan Xue
Haoyan Xue
AAAkihiro Ametani
Akihiro Ametani
JMJean Mahseredjian
Jean Mahseredjian
Ilhan KocarIlhan Kocar
Ilhan Kocar
A generalized formulation of earth-return impedance and admittance for underground cables is proposed based on a complete solution of Maxwell equations. The frequency responses of wave propagation characteristics are evaluated by the newly derived formulas and compared to those found from existing formulas in software used for the simulation of electromagnetic transients. Surge simulation results with the proposed formulas show more damping and smooth convergence to steady-state in comparison with those with existing formulas. The proposed formulas are validated with a field test on a 110 kV cross-bonded cable. It is also shown that the MoM-So method, augmented with admittance representation, verifies the results found from the new formulas presented in this paper.

30 March 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
UKUlas Karaagac
Ulas Karaagac
JMJean Mahseredjian
Jean Mahseredjian
SJSimon Jensen
Simon Jensen
RGRichard Gagnon
Richard Gagnon
MFMartin Fecteau
Martin Fecteau
Ilhan KocarIlhan Kocar
Ilhan Kocar
Subsynchronous control interaction (SSCI) is the interaction between the power-electronics control and the series-compensated transmission system that occurs at frequencies below the system nominal frequency. SSCI may occur between the doubly-fed induction generator (DFIG) control system and the series-compensated transmission line, to which the wind park (WP) is connected. Not only do the DFIG control system parameters, but also the WP operating conditions have a significant impact on SSCI. In this paper, the impact of WP operating conditions and DFIG control system parameters on SSCI is analyzed in detail. Guidelines are presented for modifying the DFIG control system parameters to ensure safe operation and acceptable transient responses due to faults. This paper also examines the accuracies of various analytical tools used for SSCI problem identification and proposes a new frequency scan analysis approach for accurate prediction of potential SSCI problems.