Andrius Sakalauskas

Dr. Andrius Sakalauskas


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2012 in BMC Neurology
Verified
Journal Article
Open access
PDF file
KLKristina Laučkaitė
Kristina Laučkaitė
DRDaiva Rastenyte
Daiva Rastenyte
DŠDanguolė Šurkienė
Danguolė Šurkienė
AVAntanas Vaitkus
Antanas Vaitkus
ASAndrius Sakalauskas
Andrius Sakalauskas
RGRYMANTĖ GLEIZNIENĖ
RYMANTĖ GLEIZNIENĖ
Hyperechogenicity of the substantia nigra (SN+), detected by transcranial sonography (TCS), was reported as a characteristic finding in Parkinson's disease (PD), with high diagnostic accuracy values, when compared mainly to healthy controls or essential tremor (ET) group. However, some data is accumulating that the SN + could be detected in other neurodegenerative and even in non-neurodegenerative disorders too. Our aim was to estimate the diagnostic accuracy of TCS, mainly focusing on the specificity point, when applied to a range of the parkinsonian disorders, and comparing to the degenerative cognitive syndromes.

1 January 2013 in Ultrasonics
Verified
Journal Article
Closed access
ASAndrius Sakalauskas
Andrius Sakalauskas
ALArūnas Lukoševičius
Arūnas Lukoševičius
KLKristina Laučkaitė
Kristina Laučkaitė
DJDarius Jegelevičius
Darius Jegelevičius
SRSaulius Rutkauskas
Saulius Rutkauskas

27 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MVMantas Vaitiekūnas
Mantas Vaitiekūnas
DJDarius Jegelevičius
Darius Jegelevičius
ASAndrius Sakalauskas
Andrius Sakalauskas
SGSimonas Grybauskas
Simonas Grybauskas
Due to technical aspects of Cone Beam Computed Tomography (CBCT), the automatic methods for bone segmentation are not widely used in the clinical practice of endodontics, orthodontics, oral and maxillofacial surgery. The aim of this study was to evaluate method’s accuracy for bone segmentation in CBCT data sets. The sliding three dimensional (3D) window, histogram filter and Otsu’s method were used to implement the automatic segmentation. The results of automatic segmentation were compared with the results of segmentation performed by an experienced oral and maxillofacial surgeon. Twenty patients and their forty CBCT data sets were used in this study (20 preoperative and 20 postoperative). Intraclass Correlation Coefficients (ICC) were calculated to prove the reliability of surgeon segmentations. ICC was 0.958 with 95% confidence interval [0.896 ... 0.983] in preoperative data sets and 0.931 with 95% confidence interval [0.836 ... 0.972] in postoperative data sets. Three basic metrics were used in order to evaluate the accuracy of the automatic method—Dice Similarity Coefficient (DSC), Root Mean Square (RMS), Average Distance Error (ADE) of surfaces mismatch and additional metric in order to evaluate computation time of segmentation was used. The mean value of preoperative DSC was 0.921, postoperative—0.911, the mean value of preoperative RMS was 0.559 mm, postoperative—0.647 mm, the ADE value of preoperative cases was 0.043 mm, postoperative—0.057 mm, the mean computational time to perform the segmentation was 46 s. The automatic method showed clinically acceptable accuracy results and thus can be used as a new tool for automatic bone segmentation in CBCT data. It can be applied in oral and maxillofacial surgery for performance of 3D Virtual Surgical Plan (VSP) or for postoperative follow-up.

21 January 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
RJRytis Jurkonis
Rytis Jurkonis
MMMonika Makūnaitė
Monika Makūnaitė
MBMindaugas Baranauskas
Mindaugas Baranauskas
ALArūnas Lukoševičius
Arūnas Lukoševičius
ASAndrius Sakalauskas
Andrius Sakalauskas
DRDaiva Rastenyte
Daiva Rastenyte
The purpose of this paper is a quantification of displacement parameters used in the imaging of brain tissue endogenous motion using ultrasonic radiofrequency (RF) signals. In a preclinical study, an ultrasonic diagnostic system with RF output was equipped with dedicated signal processing software and subject head–ultrasonic transducer stabilization. This allowed the use of RF scanning frames for the calculation of micrometer-range displacements, excluding sonographer-induced motions. Analysis of quantitative displacement estimates in dynamical phantom experiments showed that displacements of 55 µm down to 2 µm were quantified as confident according to Pearson correlation between signal fragments (minimum p ≤ 0.001). The same algorithm and scanning hardware were used in experiments and clinical imaging which allows translating phantom results to Alzheimer’s disease patients and healthy elderly subjects as examples. The confident quantitative displacement waveforms of six in vivo heart-cycle episodes ranged from 8 µm up to 263 µm (Pearson correlation p ≤ 0.01). Displacement time sequences showed promising possibilities to evaluate the morphology of endogenous displacement signals at each point of the scanning plane, while displacement maps—regional distribution of displacement parameters—were essential for tissue characterization.