Objectives The main objective of the study was to compare the accuracy of full-arch digital implant impressions for fixed dental prosthesis under in vitro and in vivo conditions. Material and Methods Eight patients (5 women and 3 men) with at least one edentulous arch and with 4-6 osseointegrated implants participated in this study. For each edentulous arch (n=10) experimental screw-retained titanium bar with attached 4 scan bodies was fabricated. The bar containing 4 scan bodies was screw-retained intraorally on implants and scanned with Trios 3 intraoral scanner 8 times (IOS group, in vivo). Then the bar was attached to the master cast and scanned 8 times again with the same intraoral scanner (MIOS group, in vitro). Finally, the bar with scan bodies was scanned 8 times with a laboratory scanner (reference). Precision and trueness were calculated for 3 distances and 3 angles between the scan bodies (1-2, 1-3, and 1-4) in IOS and MIOS groups. Results Precision and trueness for the largest distance (1-4) were found to be 44±18 µm and 32±19 µm for the IOS group, and 31±16 µm and 30±14µm for MIOS group, respectively. Precision and trueness for the angle between the most distant scan bodies (1-4) were 0.22±0.14° and 0.18±0.10° for the IOS group, and 0.16±0.11° and 0.07±0.05° for MIOS group, respectively. Conclusions Intraoral conditions moderately affected the precision and trueness of Trios 3 (3Shape) intraoral scanner. Results of in vitro accuracy studies cannot be directly transferred to the clinical field.
Due to technical aspects of Cone Beam Computed Tomography (CBCT), the automatic methods for bone segmentation are not widely used in the clinical practice of endodontics, orthodontics, oral and maxillofacial surgery. The aim of this study was to evaluate method’s accuracy for bone segmentation in CBCT data sets. The sliding three dimensional (3D) window, histogram filter and Otsu’s method were used to implement the automatic segmentation. The results of automatic segmentation were compared with the results of segmentation performed by an experienced oral and maxillofacial surgeon. Twenty patients and their forty CBCT data sets were used in this study (20 preoperative and 20 postoperative). Intraclass Correlation Coefficients (ICC) were calculated to prove the reliability of surgeon segmentations. ICC was 0.958 with 95% confidence interval [0.896 ... 0.983] in preoperative data sets and 0.931 with 95% confidence interval [0.836 ... 0.972] in postoperative data sets. Three basic metrics were used in order to evaluate the accuracy of the automatic method—Dice Similarity Coefficient (DSC), Root Mean Square (RMS), Average Distance Error (ADE) of surfaces mismatch and additional metric in order to evaluate computation time of segmentation was used. The mean value of preoperative DSC was 0.921, postoperative—0.911, the mean value of preoperative RMS was 0.559 mm, postoperative—0.647 mm, the ADE value of preoperative cases was 0.043 mm, postoperative—0.057 mm, the mean computational time to perform the segmentation was 46 s. The automatic method showed clinically acceptable accuracy results and thus can be used as a new tool for automatic bone segmentation in CBCT data. It can be applied in oral and maxillofacial surgery for performance of 3D Virtual Surgical Plan (VSP) or for postoperative follow-up.
Computer-guided dynamic navigation systems have elevated dental implant surgery into a more patient-friendly and efficient procedure. However, commercially available systems use displays as an output for guidance. This implies that surgeons have to take their eyes off the surgery site frequently in order to accurately adjust surgical instruments. The solution for such an issue is to use augmented reality (AR) head-mounted devices to showcase all necessary guiding instructions without any distractions. In this work, the implementation of augmented reality in dental surgery using the HoloLens 2 AR headset for the assessment of accuracy is described. The experiments were performed in vitro with two implementation steps, evaluating calibration and perspective of the virtual dental model alignment accuracies using a newly created marker. The calibration results showed overall accuracy and precision surpassing the 1 mm threshold in distance-related measurements. Dependency on the side on which the marker was observed and the movement of the user’s head were considered to be the most influential factors regarding the perspective of the virtual dental model alignment accuracy estimate.