Clemens Gstoettner

Dr. Clemens Gstoettner

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2020 in Journal of Neurology, Neurosurgery & Psychiatry
Verified
Journal Article
Closed access
PDF file
CGClemens Gstoettner
Clemens Gstoettner
JMJohannes A Mayer
Johannes A Mayer
SRStephanie Rassam
Stephanie Rassam
LHLaura A Hruby
Laura A Hruby
SSStefan Salminger
Stefan Salminger
OAOskar C. Aszmann
Oskar C. Aszmann
Neuralgic amyotrophy (NA), also known as Parsonage-Turner syndrome, is characterised by sudden pain attacks, followed by patchy muscle paresis in the upper extremity. Recent reports have shown that incidence is much higher than previously assumed and that the majority of patients never achieve full recovery. Traditionally, the diagnosis was mainly based on clinical observations and treatment options were confined to application of corticosteroids and symptomatic management, without proven positive effects on long-term outcomes. These views, however, have been challenged in the last years. Improved imaging methods in MRI and high-resolution ultrasound have led to the identification of structural peripheral nerve pathologies in NA, most notably hourglass-like constrictions. These pathognomonic findings have paved the way for more accurate diagnosis through high-resolution imaging. Furthermore, surgery has shown to improve clinical outcomes in such cases, indicating the viability of peripheral nerve surgery as a valuable treatment option in NA. In this review, we present an update on the current knowledge on this disease, including pathophysiology and clinical presentation, moving on to diagnostic and treatment paradigms with a focus on recent radiological findings and surgical reports. Finally, we present a surgical treatment algorithm to support clinical decision making, with the aim to encourage translation into day-to-day practice.

20 December 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LHLaura Antonia Hruby
Laura Antonia Hruby
CGClemens Gstoettner
Clemens Gstoettner
Agnes SturmaAgnes Sturma
Agnes Sturma
SSStefan Salminger
Stefan Salminger
JMJohannes A. Mayer
Johannes A. Mayer
OAOskar C. Aszmann
Oskar C. Aszmann
Global brachial plexopathies including multiple nerve root avulsions may result in complete upper limb paralysis despite surgical treatment. Bionic reconstruction, which includes the elective amputation of the functionless hand and its replacement with a mechatronic device, has been described for the transradial level. Here, we present for the first time that patients with global brachial plexus avulsion injuries and lack of biological shoulder and elbow function benefit from above-elbow amputation and prosthetic rehabilitation. Between 2012 and 2017, forty-five patients with global brachial plexus injuries approached our centre, of which nineteen (42.2%) were treated with bionic reconstruction. While fourteen patients were amputated at the transradial level, the entire upper limb was replaced with a prosthetic arm in a total of five patients. Global upper extremity function before and after bionic arm substitution was assessed using two objective hand function tests, the action research arm test (ARAT), and the Southampton hand assessment procedure (SHAP). Other outcome measures included the DASH questionnaire, VAS to assess deafferentation pain and the SF-36 health survey to evaluate changes in quality of life. Using a hybrid prosthetic arm mean ARAT scores improved from 0.6 ± 1.3 to 11.0 ± 6.7 (p = 0.042) and mean SHAP scores increased from 4.0 ± 3.7 to 13.8 ± 9.2 (p = 0.058). After prosthetic arm replacement mean DASH scores improved from 52.5 ± 9.4 to 31.2 ± 9.8 (p = 0.003). Deafferentation pain decreased from mean VAS 8.5 ± 1.0 to 6.7 ± 2.1 (p = 0.055), while the physical and mental component summary scale as part of the SF-36 health survey improved from 32.9 ± 6.4 to 40.4 ± 9.4 (p = 0.058) and 43.6 ± 8.9 to 57.3 ± 5.5 (p = 0.021), respectively. Bionic reconstruction can restore simple but robust arm and hand function in longstanding brachial plexus patients with lack of treatment alternatives.

23 February 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
CGClemens Gstoettner
Clemens Gstoettner
CFChristopher Festin
Christopher Festin
CPCosima Prahm
Cosima Prahm
Konstantin BergmeisterKonstantin Bergmeister
Konstantin Bergmeister
SSStefan Salminger
Stefan Salminger
OAOskar C. Aszmann
Oskar C. Aszmann
Background: Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. Questions/purposes: The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. Methods: We evaluated the biocompatibility of the system’s intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. Results: Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. Conclusion: As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. Clinical Relevance: In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.

16 February 2024 in Journal of Hand Surgery (European Volume)
Verified
Journal Article
Closed access
CGClemens Gstoettner
Clemens Gstoettner
GLGregor Laengle
Gregor Laengle
LHLeopold Harnoncourt
Leopold Harnoncourt
PSPaolo Sassu
Paolo Sassu
OAOskar C. Aszmann
Oskar C. Aszmann
Selective nerve transfers are used in the setting of upper limb amputation to improve myoelectric prosthesis control. This surgical concept is referred to as targeted muscle reinnervation (TMR) and describes the rerouting of the major nerves of the arm onto the motor branches of the residual limb musculature. Aside from providing additional myosignals for prosthetic control, TMR can treat and prevent neuroma pain and possibly also phantom limb pain. This article reviews the history and current applications of TMR in upper limb amputation, with a focus on practical considerations. It further explores and identifies technological innovations to improve the man–machine interface in amputation care, particularly regarding implantable interfaces, such as muscle electrodes and osseointegration. Finally, future clinical directions and possible scientific avenues in this field are presented and critically discussed.

1 July 2019 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
CGClemens Gstoettner
Clemens Gstoettner
JMJohannes A Mayer
Johannes A Mayer
MAMartin Aman
Martin Aman
SSStefan Salminger
Stefan Salminger
HBHeinz Bürger
Heinz Bürger
OAOskar C. Aszmann
Oskar C. Aszmann

21 May 2024 in Journal of Rehabilitation Medicine
Verified
Journal Article
Open access
PDF file
Agnes SturmaAgnes Sturma
Agnes Sturma
ABAnna Boesendorfer
Anna Boesendorfer
CGClemens Gstoettner
Clemens Gstoettner
BBBenedikt Baumgartner
Benedikt Baumgartner
SSStefan Salminger
Stefan Salminger
OAOskar C. Aszmann
Oskar C. Aszmann
Objective: To describe and evaluate the combination of osseointegration and nerve transfers in 3 transhumeral amputees. Design: Case series. Patients: Three male patients with a unilateral traumatic transhumeral amputation. Methods: Patients received a combination of osseointegration and targeted muscle reinnervation surgery. Rehabilitation included graded weight training, range of motion exercises, biofeedback, table-top prosthesis training, and controlling the actual device. The impairment in daily life, health-related quality of life, and pain before and after the intervention was evaluated in these patients. Their shoulder range of motion, prosthesis embodiment, and function were documented at a 2- to 5-year follow-up. Results: All 3 patients attended rehabilitation and used their myoelectric prosthesis on a daily basis. Two patients had full shoulder range of motion with the prosthesis, while the other patient had 55° of abduction and 45° of anteversion. They became more independent in their daily life activities after the intervention and incorporated their prosthesis into their body scheme to a high extent. Conclusion: These results indicate that patients can benefit from the combined procedure. However, the patients’ perspective, risks of the surgical procedures, and the relatively long rehabilitation procedure need to be incorporated in the decision-making.