Agnes Sturma

Dr. Agnes Sturma

Medical University of Vienna
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2021 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
IVIvan Vujaklija
Ivan Vujaklija
RBRickard Brånemark
Rickard Brånemark
ABAnthony M.J. Bull
Anthony M.J. Bull
HDHans Dietl
Hans Dietl
OAOskar C. Aszmann
Oskar C. Aszmann

17 July 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
SSS. Salminger
S. Salminger
Agnes SturmaAgnes Sturma
Agnes Sturma
CHC. Hofer
C. Hofer
MEM. Evangelista
M. Evangelista
MPM. Perrin
M. Perrin
OAOskar C. Aszmann
Oskar C. Aszmann
The use of implantable myoelectric sensors showed substantial improvements in prosthetic function of above-elbow amputees.

1 January 2022 in Journal of Hand Therapy
Verified
Journal Article
Open access
Agnes SturmaAgnes Sturma
Agnes Sturma
TSTanja Alexandra Stamm
Tanja Alexandra Stamm
LHLaura A. Hruby
Laura A. Hruby
BBBirgit Bischof
Birgit Bischof
SSStefan Salminger
Stefan Salminger
OAOskar C. Aszmann
Oskar C. Aszmann
This is a Delphi study based on a scoping literature review. Targeted muscle reinnervation (TMR) enables patients with high upper limb amputations to intuitively control a prosthetic arm with up to six independent control signals. Although there is a broad agreement regarding the importance of structured motor learning and prosthetic training after such nerve transfers, to date, no evidence-based protocol for rehabilitation after TMR exists. We aimed at developing a structured rehabilitation protocol after TMR surgery after major upper limb amputation. The purpose of the protocol is to guide clinicians through the full rehabilitation process, from presurgical patient education to functional prosthetic training. European clinicians and researchers working in upper limb prosthetic rehabilitation were invited to contribute to a web-based Delphi study. Within the first round, clinical experts were presented a summary of recent literature and were asked to describe the rehabilitation steps based on their own experience and scientific evidence. The second round was used to refine these steps, while the importance of each step was rated within the third round. Experts agreed on a rehabilitation protocol that consists of 16 steps and starts before surgery. It is based on two overarching principles, namely the necessity of multiprofessional teamwork and a careful selection and education of patients within the rehabilitation team. Among the different steps in therapy, experts rated the training with electromyographic biofeedback as the most important one. Within this study, a first rehabilitation protocol for TMR patients based on a broad experts' consensus and relevant literature could be developed. The detailed steps for rehabilitation start well before surgery and prosthetic fitting, and include relatively novel interventions as motor imagery and biofeedback. Future studies need to further investigate the clinical outcomes and thereby improve therapists' practice. Graded rehabilitation offered by a multiprofessional team is needed to enable individuals with upper limb amputations and TMR to fully benefit from prosthetic reconstruction. Low.

20 December 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LHLaura Antonia Hruby
Laura Antonia Hruby
CGClemens Gstoettner
Clemens Gstoettner
Agnes SturmaAgnes Sturma
Agnes Sturma
SSStefan Salminger
Stefan Salminger
JMJohannes A. Mayer
Johannes A. Mayer
OAOskar C. Aszmann
Oskar C. Aszmann
Global brachial plexopathies including multiple nerve root avulsions may result in complete upper limb paralysis despite surgical treatment. Bionic reconstruction, which includes the elective amputation of the functionless hand and its replacement with a mechatronic device, has been described for the transradial level. Here, we present for the first time that patients with global brachial plexus avulsion injuries and lack of biological shoulder and elbow function benefit from above-elbow amputation and prosthetic rehabilitation. Between 2012 and 2017, forty-five patients with global brachial plexus injuries approached our centre, of which nineteen (42.2%) were treated with bionic reconstruction. While fourteen patients were amputated at the transradial level, the entire upper limb was replaced with a prosthetic arm in a total of five patients. Global upper extremity function before and after bionic arm substitution was assessed using two objective hand function tests, the action research arm test (ARAT), and the Southampton hand assessment procedure (SHAP). Other outcome measures included the DASH questionnaire, VAS to assess deafferentation pain and the SF-36 health survey to evaluate changes in quality of life. Using a hybrid prosthetic arm mean ARAT scores improved from 0.6 ± 1.3 to 11.0 ± 6.7 (p = 0.042) and mean SHAP scores increased from 4.0 ± 3.7 to 13.8 ± 9.2 (p = 0.058). After prosthetic arm replacement mean DASH scores improved from 52.5 ± 9.4 to 31.2 ± 9.8 (p = 0.003). Deafferentation pain decreased from mean VAS 8.5 ± 1.0 to 6.7 ± 2.1 (p = 0.055), while the physical and mental component summary scale as part of the SF-36 health survey improved from 32.9 ± 6.4 to 40.4 ± 9.4 (p = 0.058) and 43.6 ± 8.9 to 57.3 ± 5.5 (p = 0.021), respectively. Bionic reconstruction can restore simple but robust arm and hand function in longstanding brachial plexus patients with lack of treatment alternatives.

12 August 2016
Verified
Book Chapter
Open access
PDF file
Agnes SturmaAgnes Sturma
Agnes Sturma
VRValentin Ritschl
Valentin Ritschl
SDSilke Dennhardt
Silke Dennhardt
TSTanja Alexandra Stamm
Tanja Alexandra Stamm
Ist das Ziel eines Forschungsvorhabens, sich mit bereits bestehender Literatur kritisch auseinanderzusetzten, existieren dazu unterschiedliche Verfahren der Literaturstudien und Reviews. Dieser Abschnitt des Buches beschreibt diese unterschiedlichen Arten von Reviews, ihre Durchführung sowie ihre Bedeutung als eigene Forschungsmethode.

23 February 2022 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
CGClemens Gstoettner
Clemens Gstoettner
CFChristopher Festin
Christopher Festin
CPCosima Prahm
Cosima Prahm
Konstantin BergmeisterKonstantin Bergmeister
Konstantin Bergmeister
SSStefan Salminger
Stefan Salminger
OAOskar C. Aszmann
Oskar C. Aszmann
Background: Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. Questions/purposes: The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. Methods: We evaluated the biocompatibility of the system’s intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. Results: Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. Conclusion: As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. Clinical Relevance: In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.