Philippe Dussart

Dr. Philippe Dussart

IPC - Institut Pasteur du Cambodge, Head of the Virology Unit. Phnom Penh, Cambodia
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2015 in Nature
Verified
Journal Article
Closed access
ARAlexander Rouvinski
Alexander Rouvinski
Pablo Guardado-CalvoPablo Guardado-Calvo
Pablo Guardado-Calvo
GBGiovanna Barba-Spaeth
Giovanna Barba-Spaeth
SDStéphane Duquerroy
Stéphane Duquerroy
MVMarie-Christine Vaney
Marie-Christine Vaney
FRFelix Rey
Felix Rey

19 August 2019 in Virus Genes
Verified
Journal Article
Open access
PDF file
ASAnnika Suttie
Annika Suttie
YDYi-Mo Deng
Yi-Mo Deng
AGAndrew R. Greenhill
Andrew R. Greenhill
PDPhilippe Dussart
Philippe Dussart
Paul HorwoodPaul Horwood
Paul Horwood
EKErik Karlsson
Erik Karlsson
Avian influenza viruses (AIVs) circulate globally, spilling over into domestic poultry and causing zoonotic infections in humans. Fortunately, AIVs are not yet capable of causing sustained human-to-human infection; however, AIVs are still a high risk as future pandemic strains, especially if they acquire further mutations that facilitate human infection and/or increase pathogenesis. Molecular characterization of sequencing data for known genetic markers associated with AIV adaptation, transmission, and antiviral resistance allows for fast, efficient assessment of AIV risk. Here we summarize and update the current knowledge on experimentally verified molecular markers involved in AIV pathogenicity, receptor binding, replicative capacity, and transmission in both poultry and mammals with a broad focus to include data available on other AIV subtypes outside of A/H5N1 and A/H7N9.

1 November 2006 in Clinical and Vaccine Immunology
Verified
Journal Article
Closed access
PDPhilippe Dussart
Philippe Dussart
BLBhety Labeau
Bhety Labeau
GLGisèlE Lagathu
GisèlE Lagathu
PLPhilippe Louis
Philippe Louis
MNMarcio Roberto Teixera Nunes
Marcio Roberto Teixera Nunes
LBLaurence Baril
Laurence Baril
We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.

22 October 2021 in Science
Verified
Journal Article
Open access
EWEduan Wilkinson
Eduan Wilkinson
Marta GiovanettiMarta Giovanetti
Marta Giovanetti
HTHouriiyah Tegally
Houriiyah Tegally
JSJames Emmanuel San
James Emmanuel San
RLRichard Lessells
Richard Lessells
TOTulio De Oliveira
Tulio De Oliveira
SARS-CoV-2 across Africa: The impact of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been hard to track in African countries, largely because of patchy data. Wilkinson et al . curated viral genomes collected in 2021 from several countries across the continent. Outbreaks during 2020 in each African country were initiated by imported cases, mostly from Europe. As the pandemic developed, case numbers in African countries were likely many times higher than reported, and subsequent waves of the pandemic appear to have been more severe. Consequently, high-transmission variants have emerged that have spread within the continent, and African countries must be included in global control efforts. —CA

9 November 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
DDDeborah Delaune
Deborah Delaune
VHVibol HUL
Vibol HUL
EKErik Karlsson
Erik Karlsson
AHAlexandre Hassanin
Alexandre Hassanin
TOTey Putita Ou
Tey Putita Ou
VDVeasna Duong
Veasna Duong
Knowledge of the origin and reservoir of the coronavirus responsible for the ongoing COVID-19 pandemic is still fragmentary. To date, the closest relatives to SARS-CoV-2 have been detected in Rhinolophus bats sampled in the Yunnan province, China. Here we describe the identification of SARS-CoV-2 related coronaviruses in two Rhinolophus shameli bats sampled in Cambodia in 2010. Metagenomic sequencing identifies nearly identical viruses sharing 92.6% nucleotide identity with SARS-CoV-2. Most genomic regions are closely related to SARS-CoV-2, with the exception of a region of the spike, which is not compatible with human ACE2-mediated entry. The discovery of these viruses in a bat species not found in China indicates that SARS-CoV-2 related viruses have a much wider geographic distribution than previously reported, and suggests that Southeast Asia represents a key area to consider for future surveillance for coronaviruses.

20 August 2008 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
PDPhilippe Dussart
Philippe Dussart
LPLaure Petit
Laure Petit
BLBhety Labeau
Bhety Labeau
LBLaetitia Bremand
Laetitia Bremand
ALAlexandre Leduc
Alexandre Leduc
LBLaurence Baril
Laurence Baril
We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection—an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)—with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP—the first rapid diagnostic test for DENV infection—was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection. Dengue is a viral disease transmitted by mosquitoes that is endemic in more than 100 countries in tropical areas, threatening over 2.5 billion people. It causes a wide range of symptoms and has severe forms. In reference laboratories, dengue disease is confirmed by virus isolation or genome detection during the acute phase, and by serological methods during the early convalescent phase. The viral NS1 protein circulates in the sera of infected patients throughout the clinical phase of the disease. Novel diagnostic tests based on NS1 detection have been recently developed and marketed. We compared the performance of two tests for detecting dengue NS1 protein during the clinical phase of dengue infection (an immunochromatographic test (ICT) from Bio-Rad allowing rapid detection of the NS1 antigen and a two-step sandwich-format ELISA from Panbio) with the one-step sandwich-format microplate ELISA (Bio-Rad). The ICT test performed better than the ELISA test from Panbio. This study confirms that diagnostic tests based on NS1 could be used in routine clinical practice in poorly equipped laboratories and that dengue diagnosis could therefore be confirmed without the need for testing in reference laboratories. This represents a crucial step towards the control of dengue disease in the human population.