Yen-Heng Lin

Prof. Yen-Heng Lin

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SHSong-Bin Huang
Song-Bin Huang
MWMin-Hsien Wu
Min-Hsien Wu
YLYen-Heng Lin
Yen-Heng Lin
CHChia-Hsun Hsieh
Chia-Hsun Hsieh
CYChih-Liang Yang
Chih-Liang Yang
GLGwo-Bin Lee
Gwo-Bin Lee
Negative selection-based circulating tumor cell (CTC) isolation is believed valuable to harvest more native, and in particular all possible CTCs without biases relevant to the properties of surface antigens on the CTCs. Under such a cell isolation strategy, however, the CTC purity is normally compromised. To address this issue, this study reports the integration of optically-induced-dielectrophoretic (ODEP) force-based cell manipulation, and a laminar flow regime in a microfluidic platform for the isolation of untreated, and highly pure CTCs after conventional negative selection-based CTC isolation. In the design, six sections of moving light-bar screens were continuously and simultaneously exerted in two parallel laminar flows to concurrently separate the cancer cells from the leukocytes based on their size difference and electric properties. The separated cell populations were further partitioned, delivered, and collected through the two flows. With this approach, the cancer cells can be isolated in a continuous, effective, and efficient manner. In this study, the operating conditions of ODEP for the manipulation of prostate cancer (PC-3) and human oral cancer (OEC-M1) cells, and leukocytes with minor cell aggregation phenomenon were first characterized. Moreover, performances of the proposed method for the isolation of cancer cells were experimentally investigated. The results showed that the presented CTC isolation scheme was able to isolate PC-3 cells or OEC-M1 cells from a leukocyte background with high recovery rate (PC-3 cells: 76–83%, OEC-M1 cells: 61–68%), and high purity (PC-3 cells: 74–82%, OEC-M1 cells: 64–66%) (set flow rate: 0.1 μl min−1 and sample volume: 1 μl). The latter is beyond what is currently possible in the conventional CTC isolations. Moreover, the viability of isolated cancer cells was evaluated to be as high as 94 ± 2%, and 95 ± 3% for the PC-3, and OEC-M1 cells, respectively. Furthermore, the isolated cancer cells were also shown to preserve their proliferative capability. As a whole, this study has presented an ODEP-based microfluidic platform that is capable of isolating CTCs in a continuous, label-free, cell-friendly, and particularly highly pure manner. All these traits are found particularly meaningful for exploiting the harvested CTCs for the subsequent cell-based, or biochemical assays.

1 May 2013 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YLYen-Heng Lin
Yen-Heng Lin
SWShih-Hao Wang
Shih-Hao Wang
MWMin-Hsien Wu
Min-Hsien Wu
TPTung-Ming Pan
Tung-Ming Pan
Chao-Sung LaiChao-Sung Lai
Chao-Sung Lai
CCChiuan-Chian Chiou
Chiuan-Chian Chiou

5 January 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYen-Heng Lin
Yen-Heng Lin
YYYa-Wen Yang
Ya-Wen Yang
YCYi-Dao Chen
Yi-Dao Chen
SWShih-Siou Wang
Shih-Siou Wang
YCYu-Han Chang
Yu-Han Chang
Min-Hsien WuMin-Hsien Wu
Min-Hsien Wu
This study reports the utilisation of an optically switched dielectrophoretic (ODEP) force for the manipulation and assembly of cell-encapsulating alginate microbeads in a microfluidic perfusion cell culture system for bottom-up tissue engineering. One of the key features of this system is the ODEP force-based mechanism, which allows a commercial projector to be coupled with a computer to manipulate and assemble cell-encapsulating microbeads in an efficient, manageable, and user-friendly manner. Another distinctive feature is the design of the microfluidic cell culture chip, which allows the patterned cell-encapsulating microbeads to be cultivated on site under culture medium perfusion conditions. For demonstrating its application in bottom-up cartilage tissue engineering, chondrocyte-encapsulating alginate microbeads varying in encapsulated cell densities were generated. The manipulation forces associated with operating the alginate microbeads were experimentally evaluated. The results revealed that the measured manipulation forces increased with increases in both the applied electric voltage and the number of cells in the alginate microbeads. Nevertheless, the observed manipulation force was found to be independent of the size of the cell-free alginate microbeads. It can be speculated that the friction force may influence the estimation of the ODEP force within the experimental conditions investigated. In this study, chondrocyte-encapsulating alginate microbeads with three different cell densities were manipulated and assembled in the proposed microfluidic system to form a compact sheet-like cell culture construct that imitates the cell distribution in the cross-section of native articular cartilage. Moreover, the demonstration case also showed that the cell viability of the cultured cells in the microfluidic system remained as high as 96 ± 2%. In this study, four sheet-like cell culture constructs were stacked to create a larger assembled cell culture construct. The cell distribution inside the cell culture construct was further confirmed by a confocal microscopy observation, which showed that the distribution was similar to that in native articular cartilage. As a whole, the proposed system holds great promise as a platform for engineering tissue constructs with easily tunable inner cell distributions.

19 March 2010 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
YLYen-Heng Lin
Yen-Heng Lin
GLGwo-Bin Lee
Gwo-Bin Lee

26 August 2016 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
YLYen-Heng Lin
Yen-Heng Lin
ILI Chi Lee
I Chi Lee
WHWei-Chieh Hsu
Wei-Chieh Hsu
CHChing-Hong Hsu
Ching-Hong Hsu
KCKai-Ping Chang
Kai-Ping Chang
SGShao-Syuan Gao
Shao-Syuan Gao

1 March 2013 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
YLYen-Heng Lin
Yen-Heng Lin
YCYing-Ju Chen
Ying-Ju Chen
Chao-Sung LaiChao-Sung Lai
Chao-Sung Lai
Yi-Ting ChenYi-Ting Chen
Yi-Ting Chen
CCChien-Lun Chen
Chien-Lun Chen
YCYu-Sun Chang
Yu-Sun Chang
This paper describes an integrated microfluidic chip that is capable of rapidly and quantitatively measuring the concentration of a bladder cancer biomarker, apolipoprotein A1, in urine samples. All of the microfluidic components, including the fluid transport system, the micro-valve, and the micro-mixer, were driven by negative pressure, which simplifies the use of the chip and facilitates commercialization. Magnetic beads were used as a solid support for the primary antibody, which captured apolipoprotein A1 in patients' urine. Because of the three-dimensional structure of the magnetic beads, the concentration range of the target that could be detected was as high as 2000 ng ml−1. Because this concentration is 100 times higher than that quantifiable using a 96-well plate with the same enzyme-linked immunosorbent assay (ELISA) kit, the dilution of the patient's urine can be avoided or greatly reduced. The limit of detection was determined to be approximately 10 ng ml−1, which is lower than the cutoff value for diagnosing bladder cancer (11.16 ng ml−1). When the values measured using the microfluidic chip were compared with those measured using conventional ELISA using a 96-well plate for five patients, the deviations were 0.9%, 6.8%, 9.4%, 1.8%, and 5.8%. The entire measurement time is 6-fold faster than that of conventional ELISA. This microfluidic device shows significant potential for point-of-care applications.