This paper investigates the morphology, thermal, and electrical properties of LDPE (low-density polyethylene)-based nanocomposites after thermal aging. The FTIR (Fourier transform infrared spectroscopy) spectra results show that thermo-oxidative reactions occur in neat LDPE and LDPE/SiO2 nanocomposites when the aging time is 35 days and in LDPE/MgO nanocomposites when the aging time is 77 days. Specifically, LDPE/MgO nanocomposites delay the appearance of thermo-oxidative reactions, showing anti-thermal aging ability. Furthermore, nanocomposites present lower onset degradation temperature than neat LDPE, showing better thermal stabilization. With regard to the electrical properties, nanocomposites maintain the ability to suppress space charge accumulation after thermal aging. Additionally, in comparison with SiO2 nanocomposites and neat LDPE, the permittivity of LDPE/MgO nanocomposites changes slightly after thermal aging. It is concluded that LDPE/MgO nanocomposites have better insulation properties than neat LDPE after thermal aging, which may be caused by the interface introduced by the nanoparticles.
The overall life of oil-immersed power transformers depends on the long-term life of the oil–paper insulation system throughout continuous operation. Studying the reliability assessment methods for oil–paper insulation can help determine the reliability level of power transformers accurately, and ensure their safe and stable operation. In the present paper, the life of oil–paper insulation is proven to obey the Weibull distribution under eight different temperatures set by the Weibull reliability probability paper; the failure mechanisms of the different temperatures are highly consistent. The Weibull distribution reliability curve cluster of oil–paper insulation is plotted under different temperatures by which an oil–paper insulation reliability assessment method is proposed. Lastly, the statistical validation experiment of the proposed method is conducted, which proves its theoretical validity. Thus, the present study puts forward a simple and effective method for the oil–paper insulation reliability assessment of power transformers under different temperatures at different life stages.
We first report universal strategies to synthesize high-loading (up to 13.78 wt%) non-metal monoatoms on carbon. Re-calcination is further proposed to overcome the poor oxidation resistance of catalysts with abundant carbon defects.
Polyethylene cables, as important transmission equipment of modern power grid, would inevitably be slightly damaged, which seriously threatens the safety of the power supply. This paper has pioneered the preparation and typical performances of a self-healing polyethylene insulating composite. The self-healing performance to structural damage was verified by tests of electrical and mechanical damage. The effect mechanism of doping microcapsules on the electrical performance of polyethylene was emphatically analyzed. The results show that in appropriate conditions (such as 60 °C/30 min), the composite can not only repair the electrical tree and scratches, but also restore the insulation strength of damaged area. The effect of doping microcapsules on the electrical performances of polyethylene, such as breakdown strength, volumetric resistivity, dielectric properties, and space charge characteristics, are mainly related to impurity and the interface of microcapsule. Polarization and ionization of impurities can reduce the electrical performance of polyethylene. The interface not only improves the microstructure of polyethylene (such as how the heterogeneous nucleation effect increases the number of crystal regions, and the anchoring effect enhances the stability of amorphous regions), but also increases the charge traps. Moreover, the microstructure and charge trap can affect the characteristics of carrier transport, material polarization, and space charge accumulation, thus improving the electrical performance of polyethylene. In addition, the important electrical performance of the composite can meet the basic application requirements of polyethylene insulating material, which has good application prospects.
To facilitate better interpretation of dielectric response measurements—thereby directing numerical evidence for condition assessments of oil-paper-insulated equipment in high-voltage alternating current (HVAC) transmission systems—a novel approach is presented to estimate the parameters in the extended Debye model (EDM) using wideband frequency domain spectroscopy (FDS). A syncretic algorithm that integrates a genetic algorithm (GA) and the Levenberg-Marquardt (L-M) algorithm is introduced in the present study to parameterize EDM using the FDS measurements of a real-life 126 kV oil-impregnated paper (OIP) bushing under different controlled temperatures. As for the uncertainty of the EDM structure due to variable branch quantity, Akaike’s information criterion (AIC) is employed to determine the model orders. For verification, comparative analysis of FDS reconstruction and results of FDS transformation to polarization–depolarization current (PDC)/return voltage measurement (RVM) are presented. The comparison demonstrates good agreement between the measured and reconstructed spectroscopies of complex capacitance and tan δ over the full tested frequency band (10−4 Hz–103 Hz) with goodness of fit over 0.99. Deviations between the tested and modelled PDC/RVM from FDS are then discussed. Compared with the previous studies to parameterize the model using time domain dielectric responses, the proposed method solves the problematic matching between EDM and FDS especially in a wide frequency band, and therefore assures a basis for quantitative insulation condition assessment of OIP-insulated apparatus in energy systems.