The main issue in this paper is the real-time simulator of a part of a power grid with a wind turbine. The simulator is constructed on the basis of a classic PC running under a classic operating system. The proposed solution is expected and desired by users who intend to manage power microgrids as separate (but not autonomous) areas of common national power systems. The main reason for the decreased interest in real-time simulators solutions built on the basis of PC is the simulation instability. The instability of the simulation is due to not keeping with accurate results when using small integration steps and loss of accuracy or loss of stability when using large integration steps. The second obstacle was due to the lack of a method for integrating differential equations, which gives accurate results with a large integration step. This is the scientific problem that is solved in this paper. A new solution is the use of a new method for integrating differential equations based on average voltage in the integration step (AVIS). This paper shows that the applied AVIS method, compared to other methods proposed in the literature (in the context of real-time simulators), allows to maintain simulation stability and accurate results with the use of large integration steps. A new (in the context of the application of the AVIS method) mathematical model of a power transformer is described in detail, taking into account the nonlinearity of the magnetization characteristics. This model, together with the new doubly-fed induction machine model (described in the authors’ previous article), was implemented in PC-based hardware. In this paper, we present the results of research on the operation states of such a developed real-time simulator over a long period (one week). In this way, the effectiveness of the operation of the real-time simulator proposed in the paper was proved.
This article deals with the issue of the reduction of the oscillation of electromagnetic torque in the case of a direct on line (DOL) starting of a 6 kV induction motor. Such engines are used in drive systems where frequent starting may be required. Direct starting in such systems may reduce the mechanical and thermal durability. Therefore, the article presents a method of DOL starting of a 6 kV induction motor with the use of vacuum circuit-breakers and appropriate switching of the voltages supplying the electric machine. To confirm the advantages of the proposed solution, computer simulation and experimental tests were carried out, which are presented and discussed in the article. The obtained results confirm the advantages of the proposed solution, compared to the classic starting known from the literature.
Currently used methods of simulation of doubly fed induction machines (DFIM), especially in real-time simulators (where a relatively large calculation step is used and high adequacy is required), do not provide the required adequacy, especially in rotor electrical circuits. In order to increase the adequacy of reproducing of electrical processes occurring in the circuits of the wound DFIM rotor, this paper presents a proposal and a verification of a new method of real-time simulation. The new method of mathematical modeling of electrical circuits uses voltage averaging at the calculation step. This method was supplemented by prediction of the machine’s rotor angle, which significantly increases the degree of adequacy of reproducing physical quantities present in DFIM, especially in the machine’s rotor. This method allows real-time simulation of electrical systems with a relatively large calculation step (of the order of 200 µs), while maintaining an appropriate degree of adequacy.
Currently, in rural networks with a large amount of distributed generation, PV installations are often disconnected due to the excessively high voltage in the network, which often exceeds the limit value, in accordance with the PN-EN 50160 standard. Disconnecting such an installation extends the return on investment costs by preventing the generation of electricity for the owner’s needs and results in the consumption of this energy from the grid. In such a case, the recipient has to bear the costs related to the purchase of this energy. In order to solve the problem of excessively high voltage in a low-voltage distribution network with a large amount of distributed generation, the authors of this article proposed a new approach to the use of electricity from these sources. In order to present the benefits of the proposed solution, a computer simulation was used. In order to carry it out, a mathematical model of a low-voltage power grid with distributed generation was developed using the electric multipole method and Newton’s method, which is discussed in the paper. To determine the advantages of the proposed solution, nine variants of the operation of an exemplary low-voltage power grid over one day were analyzed. The main conclusion based on the analysis of the results is that the proposed approach improves the operation of the power system by maintaining the voltage values within the standard range for the entire tested part of the network. In addition, the proposed approach does not increase the power or electricity when generating electricity from a PV installation. The proposed solution can also serve as a very attractive stimulus for the creation of energy cooperatives.
The development of power electronics, including high-efficiency power supply systems, changes the structure of perception of the types of electrical energy receivers connected to the power grid at each supply voltage level. In the past, the dominant type of receivers were constant impedance devices. Currently, more and more devices have power supplies, which are most often constant power receivers. The construction and technological diversity of receivers allows mixed receivers, which are a combination of constant power and constant impedance receivers, to be distinguished. Therefore, there is a need to determine the impact of the type of electrical energy receivers on the power grid, both in the context of the operation of a single receiver and in the case of a branched power grid with a high penetration of distributed generation. This article will discuss the impact of the type of electrical energy receivers on the operation of the power grid, with particular emphasis on the issue of electrical energy losses at changing voltages. To determine the impact of receivers, simulation studies were performed based on two case stages: the first is a fragment of a low-voltage power grid in a household that supplies a heating device, which is analyzed as a different type of receiver; the second is a fragment of a low-voltage power grid with various types of consumers and photovoltaic installations. The research was carried out on the basis of the mathematical model of the low-voltage power network developed by the authors using the electric multipole method and Newton’s method. The obtained results show that the type of receiver may have an impact on electrical energy losses.
Electric vehicles are increasingly appearing on Polish roads due to a number of technical, legal and marketing conditions. However, electromobility is developing primarily in urban areas, mainly due to the unevenly developed infrastructure for charging vehicle batteries and the power grid. Therefore, solutions should be created that use the existing power infrastructure, including the use of railway power infrastructure (RPI). The railway power network covers a significant part of the country, including forest areas, and, above all, it very often intersects with road infrastructure or runs along roads. This paper raises issues related to the possibility of using RPI to charge the batteries of electric vehicles. After characterizing the technical, operational and legal requirements related to these technical systems, a concept of an electric vehicle charging system using RPI was developed, along with a demonstration of the possibility of its implementation, which was simulated using mathematical models developed by the authors.