Marcelo Victor Wust Zibetti

Prof. Marcelo Victor Wust Zibetti

Radiology, New York University School of Medicine, New York, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Dilbag SinghDilbag Singh
Dilbag Singh
AMAnmol Monga
Anmol Monga
HMHector Lise de Moura
Hector Lise de Moura
XZxiaoxia zhang
xiaoxia zhang
MZMarcelo Victor Wust Zibetti
Marcelo Victor Wust Zibetti
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte
Magnetic Resonance Imaging (MRI) is an essential medical imaging modality that provides excellent soft-tissue contrast and high-resolution images of the human body, allowing us to understand detailed information on morphology, structural integrity, and physiologic processes. However, MRI exams usually require lengthy acquisition times. Methods such as parallel MRI and Compressive Sensing (CS) have significantly reduced the MRI acquisition time by acquiring less data through undersampling k-space. The state-of-the-art of fast MRI has recently been redefined by integrating Deep Learning (DL) models with these undersampled approaches. This Systematic Literature Review (SLR) comprehensively analyzes deep MRI reconstruction models, emphasizing the key elements of recently proposed methods and highlighting their strengths and weaknesses. This SLR involves searching and selecting relevant studies from various databases, including Web of Science and Scopus, followed by a rigorous screening and data extraction process using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. It focuses on various techniques, such as residual learning, image representation using encoders and decoders, data-consistency layers, unrolled networks, learned activations, attention modules, plug-and-play priors, diffusion models, and Bayesian methods. This SLR also discusses the use of loss functions and training with adversarial networks to enhance deep MRI reconstruction methods. Moreover, we explore various MRI reconstruction applications, including non-Cartesian reconstruction, super-resolution, dynamic MRI, joint learning of reconstruction with coil sensitivity and sampling, quantitative mapping, and MR fingerprinting. This paper also addresses research questions, provides insights for future directions, and emphasizes robust generalization and artifact handling. Therefore, this SLR serves as a valuable resource for advancing fast MRI, guiding research and development efforts of MRI reconstruction for better image quality and faster data acquisition.

25 February 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
MZMarcelo Victor Wust Zibetti
Marcelo Victor Wust Zibetti
ASAzadeh Sharafi
Azadeh Sharafi
RORicardo Otazo
Ricardo Otazo
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte

21 November 2018 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
MZMarcelo Victor Wust Zibetti
Marcelo Victor Wust Zibetti
EHElias S. Helou
Elias S. Helou
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte
GHGabor Herman
Gabor Herman
An improvement of the monotone fast iterative shrinkage-thresholding algorithm (MFISTA) for faster convergence is proposed in this paper. Our motivation is to reduce the reconstruction time of compressed sensing problems in magnetic resonance imaging. The proposed modification introduces an extra term, which is a multiple of the proximal-gradient step, into the so-called momentum formula used for the computation of the next iterate in MFISTA. In addition, the modified algorithm selects the next iterate as a possibly improved point obtained by any other procedure, such as an arbitrary shift, a line search, or other methods. As an example, an arbitrary-length shift in the direction from the previous iterate to the output of the proximal-gradient step is considered. The resulting algorithm accelerates MFISTA in a manner that varies with the iterative steps. Convergence analysis shows that the proposed modification provides improved theoretical convergence bounds, and that it has more flexibility in its parameters than the original MFISTA. Since such problems need to be studied in the context of functions of several complex variables, a careful extension of FISTA-like methods to complex variables is provided.

23 January 2018 in Inverse Problems
Verified
Journal Article
Closed access
PDF file
MZMarcelo Victor Wust Zibetti
Marcelo Victor Wust Zibetti
CLChuan Lin
Chuan Lin
GHGabor Herman
Gabor Herman
The conjugate gradient (CG) method is commonly used for the relatively-rapid solution of least squares problems. In image reconstruction, the problem can be ill-posed and also contaminated by noise; due to this, approaches such as regularization should be utilized. Total variation (TV) is a useful regularization penalty, frequently utilized in image reconstruction for generating images with sharp edges. When a non-quadratic norm is selected for regularization, as is the case for TV, then it is no longer possible to use CG. Non-linear CG is an alternative, but it does not share the efficiency that CG shows with least squares and methods such as fast iterative shrinkage-thresholding algorithms (FISTA) are preferred for problems with TV norm. A different approach to including prior information is superiorization. In this paper it is shown that the conjugate gradient method can be superiorized. Five different CG variants are proposed, including preconditioned CG. The CG methods superiorized by the total variation norm are presented and their performance in image reconstruction is demonstrated. It is illustrated that some of the proposed variants of the superiorized CG method can produce reconstructions of superior quality to those produced by FISTA and in less computational time, due to the speed of the original CG for least squares problems. In the Appendix we examine the behavior of one of the superiorized CG methods (we call it S-CG); one of its input parameters is a positive number ε . It is proved that, for any given ε that is greater than the half-squared-residual for the least squares solution, S-CG terminates in a finite number of steps with an output for which the half-squared-residual is less than or equal to ε . Importantly, it is also the case that the output will have a lower value of TV than what would be provided by unsuperiorized CG for the same value ε of the half-squared residual.

3 April 2023 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
MZMarcelo Victor Wust Zibetti
Marcelo Victor Wust Zibetti
RMRajiv G. Menon
Rajiv G. Menon
HMHector Lise de Moura
Hector Lise de Moura
XZxiaoxia zhang
xiaoxia zhang
RKRichard Kijowski
Richard Kijowski
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte

29 September 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MZMarcelo Victor Wust Zibetti
Marcelo Victor Wust Zibetti
GHGabor T. Herman
Gabor T. Herman
RRRavinder R. Regatte
Ravinder R. Regatte
In this study, a fast data-driven optimization approach, named bias-accelerated subset selection (BASS), is proposed for learning efficacious sampling patterns (SPs) with the purpose of reducing scan time in large-dimensional parallel MRI. BASS is applicable when Cartesian fully-sampled k-space measurements of specific anatomy are available for training and the reconstruction method for undersampled measurements is specified; such information is used to define the efficacy of any SP for recovering the values at the non-sampled k-space points. BASS produces a sequence of SPs with the aim of finding one of a specified size with (near) optimal efficacy. BASS was tested with five reconstruction methods for parallel MRI based on low-rankness and sparsity that allow a free choice of the SP. Three datasets were used for testing, two of high-resolution brain images ( $$\text {T}_{2}$$T2 -weighted images and, respectively, $$\text {T}_{1\rho }$$T1ρ -weighted images) and another of knee images for quantitative mapping of the cartilage. The proposed approach has low computational cost and fast convergence; in the tested cases it obtained SPs up to 50 times faster than the currently best greedy approach. Reconstruction quality increased by up to 45% over that provided by variable density and Poisson disk SPs, for the same scan time. Optionally, the scan time can be nearly halved without loss of reconstruction quality. Quantitative MRI and prospective accelerated MRI results show improvements. Compared with greedy approaches, BASS rapidly learns effective SPs for various reconstruction methods, using larger SPs and larger datasets; enabling better selection of sampling-reconstruction pairs for specific MRI problems.