In this study, we develop reliable and practical virtual coiling and stenting methods for intracranial aneurysm surgical planning. Since the purpose of deploying coils and stents is to provide device geometries for subsequent accurate post-treatment computational fluid dynamics analysis, we do not need to accurately capture all the details such as the stress and force distribution for the devices and vessel walls. Our philosophy for developing these methods is to balance accuracy and practicality. We consider the mechanical properties of the devices and recapitulate the clinical practice using a finite element method (FEM) approach. At the same time, we apply some simplifications for FEM modeling to make our methods efficient. For the virtual coiling, the coils are modeled as 3D Euler–Bernoulli beam elements, which is computationally efficient and provides good geometry representation. During the stent deployment process, the stent–catheter system is transformed according to the centerline of the parent vessel since the final configuration of the stent is not dependent of the deployment history. The aneurysm and vessel walls are assumed to be rigid and are fully constrained during the simulation. All stent–catheter system and coil–catheter system are prepared and packaged as a library which contains all types of stents, coils and catheters, which improves the efficiency of surgical planning process. The stent was delivered to the suitable position during the clinical treatment, achieving good expansion and apposition of the stent to the arterial wall. The coil was deployed into the aneurysm sac and deformed to different shapes because of the stored strain energy during coil package process and the direction of the microcatheter. The method which we develop here could become surgical planning for intracranial aneurysm treatment in the clinical workflow.
17 May 2022 in Computer Methods and Programs in Biomedicine
Original Article Angiography-based index of microcirculatory resistance (AccuIMR) for the assessment of microvascular dysfunction in acute coronary syndrome and chronic coronary syndrome Yongzhen Fan, Chenguang Li, Yumeng Hu, Xiaorong Hu, Shuang Wang, Jingsong He, Xiaochang Leng, Jianping Xiang, Zhibing Lu
Background: Intravascular ultrasound (IVUS) is the golden standard in accessing the coronary lesions, stenosis, and atherosclerosis plaques. In this paper, a fully automatic approach by an 8-layer U-Net is developed to segment the coronary artery lumen and the area bounded by external elastic membrane (EEM), i.e., cross-sectional area (EEM-CSA). The database comprises single-vendor and single-frequency IVUS data. Particularly, the proposed data augmentation of MeshGrid combined with flip and rotation operations is implemented, improving the model performance without pre- or post-processing of the raw IVUS images.Results: The mean intersection of union (MIoU) of 0.937 and 0.804 for the lumen and EEM-CSA, respectively, were achieved, which exceeded the manual labeling accuracy of the clinician.Conclusion: The accuracy shown by the proposed method is sufficient for subsequent reconstruction of 3D-IVUS images, which is essential for doctors’ diagnosis in the tissue characterization of coronary artery walls and plaque compositions, qualitatively and quantitatively.