Ive Weygers

Dr. Ive Weygers

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
IWIve Weygers
Ive Weygers
MKManon Kok
Manon Kok
MKMarco Konings
Marco Konings
HHHans Hallez
Hans Hallez
HVHenri De Vroey
Henri De Vroey
KCKurt Claeys
Kurt Claeys
The use of inertial measurement units (IMUs) has gained popularity for the estimation of lower limb kinematics. However, implementations in clinical practice are still lacking. The aim of this review is twofold—to evaluate the methodological requirements for IMU-based joint kinematic estimation to be applicable in a clinical setting, and to suggest future research directions. Studies within the PubMed, Web Of Science and EMBASE databases were screened for eligibility, based on the following inclusion criteria: (1) studies must include a methodological description of how kinematic variables were obtained for the lower limb, (2) kinematic data must have been acquired by means of IMUs, (3) studies must have validated the implemented method against a golden standard reference system. Information on study characteristics, signal processing characteristics and study results was assessed and discussed. This review shows that methods for lower limb joint kinematics are inherently application dependent. Sensor restrictions are generally compensated with biomechanically inspired assumptions and prior information. Awareness of the possible adaptations in the IMU-based kinematic estimates by incorporating such prior information and assumptions is necessary, before drawing clinical decisions. Future research should focus on alternative validation methods, subject-specific IMU-based biomechanical joint models and disturbed movement patterns in real-world settings.

23 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
IWIve Weygers
Ive Weygers
MKManon Kok
Manon Kok
HVHenri De Vroey
Henri De Vroey
TVTommy Verbeerst
Tommy Verbeerst
MVMark Versteyhe
Mark Versteyhe
KCKurt Claeys
Kurt Claeys
The ability to capture joint kinematics in outside-laboratory environments is clinically relevant. In order to estimate kinematics, inertial measurement units can be attached to body segments and their absolute orientations can be estimated. However, the heading part of such orientation estimates is known to drift over time, resulting in drifting joint kinematics. This study proposes a novel joint kinematic estimation method that tightly incorporates the connection between adjacent segments within a sensor fusion algorithm, to obtain drift-free joint kinematics. Drift in the joint kinematics is eliminated solely by utilizing common information in the accelerometer and gyroscope measurements of sensors placed on connecting segments. Both an optimization-based smoothing and a filtering approach were implemented. Validity was assessed on a robotic manipulator under varying measurement durations and movement excitations. Standard deviations of the estimated relative sensor orientations were below 0.89° in an optimization-based smoothing implementation for all robot trials. The filtering implementation yielded similar results after convergence. The method is proven to be applicable in biomechanics, with a prolonged gait trial of 7 minutes on 11 healthy subjects. Three-dimensional knee joint angles were estimated, with mean RMS errors of 2.14°, 1.85°, 3.66° in an optimization-based smoothing implementation and mean RMS errors of 3.08°, 2.42°, 4.47° in a filtering implementation, with respect to a golden standard optical motion capture reference system.

Verified
Journal Article
Open access
PDF file
HVHenri De Vroey
Henri De Vroey
KCKurt Claeys
Kurt Claeys
Keivan SHARIATMADARKeivan SHARIATMADAR
Keivan SHARIATMADAR
IWIve Weygers
Ive Weygers
EVEvie Vereecke
Evie Vereecke
FSFilip Staes
Filip Staes
Background: Kinesiophobia is a psycho-cognitive factor that hampers recovery after orthopedic surgery. No evidence exists on the influence of kinesiophobia on the short-term recovery of function in patients with knee replacement (KR). Therefore, the aim of the present study is to investigate the impact of kinesiophobia on short-term patient-reported outcomes (PROMs) and performance-based measures (PBMs). Methods: Forty-three KR patients filled in the Tampa scale for kinesiophobia (TSK) at time of discharge. Patients with TSK ≥ 37 were allocated to the kinesiophobia group (n = 24), others to the no-kinesiophobia group (n = 19). Patients were asked to complete PROMs and to execute PBMs at discharge and at 6-weeks follow-up. An independent samples t-test was used to compare group differences for PROMs and PBMs at both measurement sessions. Multiple linear regression analysis models were used to model PBM outcomes from age, pain and TSK scores. Results: Significant differences were observed between groups for PROMs and PBMs. Kinesiophobia significantly contributed to the reduced functional outcomes. Conclusion: At discharge from the hospital, 55.8% of KR patients demonstrated high levels of kinesiophobia (TSK ≥ 37). This may negatively influence short-term recovery of these patients, by putting them at higher risk for falling and reduced functionality.

15 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DLDaniel Laidig
Daniel Laidig
IWIve Weygers
Ive Weygers
TSThomas Seel
Thomas Seel
Human motion analysis using inertial measurement units (IMUs) has recently been shown to provide accuracy similar to the gold standard, optical motion capture, but at lower costs and while being less restrictive and time-consuming. However, IMU-based motion analysis requires precise knowledge of the orientations in which the sensors are attached to the body segments. This knowledge is commonly obtained via time-consuming and error-prone anatomical calibration based on precisely defined poses or motions. In the present work, we propose a self-calibrating approach for magnetometer-free joint angle tracking that is suitable for joints with two degrees of freedom (DoF), such as the elbow, ankle, and metacarpophalangeal finger joints. The proposed methods exploit kinematic constraints in the angular rates and the relative orientations to simultaneously identify the joint axes and the heading offset. The experimental evaluation shows that the proposed methods are able to estimate plausible and consistent joint axes from just ten seconds of arbitrary elbow joint motion. Comparison with optical motion capture shows that the proposed methods yield joint angles with similar accuracy as a conventional IMU-based method while being much less restrictive. Therefore, the proposed methods improve the practical usability of IMU-based motion tracking in many clinical and biomedical applications.

1 November 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
IWIve Weygers
Ive Weygers
MKManon Kok
Manon Kok
TSThomas Seel
Thomas Seel
DSDarshan Shah
Darshan Shah
OTOrçun Taylan
Orçun Taylan
KCKurt Claeys
Kurt Claeys

21 August 2023 in IEEE Sensors Letters
Verified
Journal Article
Closed access
SBSimon Bachhuber
Simon Bachhuber
DLDustin Lehmann
Dustin Lehmann
EDEva Dorschky
Eva Dorschky
AKAnne Koelewijn
Anne Koelewijn
TSThomas Seel
Thomas Seel
IWIve Weygers
Ive Weygers
Inertial measurement units (IMUs) are used for inertial motion tracking (IMT) in a growing number of applications as sensor fusion methods are being advanced in three directions: magnetometer-free IMT methods that eliminate the effect of magnetic disturbances; sparse IMT approaches that lead to reduced setup complexity; and automatic self-calibration of sensor-to-segment positions or orientations. In this letter, we propose an approach that combines all three achievements and, for the first time, enables plug-and-play, magnetometer-free, and sparse IMT. This is accomplished by training a recurrent neural-network-based observer (RNNo) on just-in-time generated simulated motion data of kinematic chains. We demonstrate that domain-specific training data augmentations lead to a trained RNNo which zero shot generalizes to previously unseen experimental data and, thus, overcomes the sim-to-real gap. The trained RNNo achieves a tracking error of $< 4$ degrees when estimating the relative pose of a three-segment kinematic chain with two hinge joints. The proposed method offers a novel simulation-data-driven approach for solving complex sparse sensing problems while assuring robust and plug-and-play generalizability to experimental data.