Henri De Vroey

Dr. Henri De Vroey


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
IWIve Weygers
Ive Weygers
MKManon Kok
Manon Kok
MKMarco Konings
Marco Konings
HHHans Hallez
Hans Hallez
HVHenri De Vroey
Henri De Vroey
KCKurt Claeys
Kurt Claeys
The use of inertial measurement units (IMUs) has gained popularity for the estimation of lower limb kinematics. However, implementations in clinical practice are still lacking. The aim of this review is twofold—to evaluate the methodological requirements for IMU-based joint kinematic estimation to be applicable in a clinical setting, and to suggest future research directions. Studies within the PubMed, Web Of Science and EMBASE databases were screened for eligibility, based on the following inclusion criteria: (1) studies must include a methodological description of how kinematic variables were obtained for the lower limb, (2) kinematic data must have been acquired by means of IMUs, (3) studies must have validated the implemented method against a golden standard reference system. Information on study characteristics, signal processing characteristics and study results was assessed and discussed. This review shows that methods for lower limb joint kinematics are inherently application dependent. Sensor restrictions are generally compensated with biomechanically inspired assumptions and prior information. Awareness of the possible adaptations in the IMU-based kinematic estimates by incorporating such prior information and assumptions is necessary, before drawing clinical decisions. Future research should focus on alternative validation methods, subject-specific IMU-based biomechanical joint models and disturbed movement patterns in real-world settings.

23 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
IWIve Weygers
Ive Weygers
MKManon Kok
Manon Kok
HVHenri De Vroey
Henri De Vroey
TVTommy Verbeerst
Tommy Verbeerst
MVMark Versteyhe
Mark Versteyhe
KCKurt Claeys
Kurt Claeys
The ability to capture joint kinematics in outside-laboratory environments is clinically relevant. In order to estimate kinematics, inertial measurement units can be attached to body segments and their absolute orientations can be estimated. However, the heading part of such orientation estimates is known to drift over time, resulting in drifting joint kinematics. This study proposes a novel joint kinematic estimation method that tightly incorporates the connection between adjacent segments within a sensor fusion algorithm, to obtain drift-free joint kinematics. Drift in the joint kinematics is eliminated solely by utilizing common information in the accelerometer and gyroscope measurements of sensors placed on connecting segments. Both an optimization-based smoothing and a filtering approach were implemented. Validity was assessed on a robotic manipulator under varying measurement durations and movement excitations. Standard deviations of the estimated relative sensor orientations were below 0.89° in an optimization-based smoothing implementation for all robot trials. The filtering implementation yielded similar results after convergence. The method is proven to be applicable in biomechanics, with a prolonged gait trial of 7 minutes on 11 healthy subjects. Three-dimensional knee joint angles were estimated, with mean RMS errors of 2.14°, 1.85°, 3.66° in an optimization-based smoothing implementation and mean RMS errors of 3.08°, 2.42°, 4.47° in a filtering implementation, with respect to a golden standard optical motion capture reference system.

Verified
Journal Article
Open access
PDF file
HVHenri De Vroey
Henri De Vroey
KCKurt Claeys
Kurt Claeys
Keivan SHARIATMADARKeivan SHARIATMADAR
Keivan SHARIATMADAR
IWIve Weygers
Ive Weygers
EVEvie Vereecke
Evie Vereecke
FSFilip Staes
Filip Staes
Background: Kinesiophobia is a psycho-cognitive factor that hampers recovery after orthopedic surgery. No evidence exists on the influence of kinesiophobia on the short-term recovery of function in patients with knee replacement (KR). Therefore, the aim of the present study is to investigate the impact of kinesiophobia on short-term patient-reported outcomes (PROMs) and performance-based measures (PBMs). Methods: Forty-three KR patients filled in the Tampa scale for kinesiophobia (TSK) at time of discharge. Patients with TSK ≥ 37 were allocated to the kinesiophobia group (n = 24), others to the no-kinesiophobia group (n = 19). Patients were asked to complete PROMs and to execute PBMs at discharge and at 6-weeks follow-up. An independent samples t-test was used to compare group differences for PROMs and PBMs at both measurement sessions. Multiple linear regression analysis models were used to model PBM outcomes from age, pain and TSK scores. Results: Significant differences were observed between groups for PROMs and PBMs. Kinesiophobia significantly contributed to the reduced functional outcomes. Conclusion: At discharge from the hospital, 55.8% of KR patients demonstrated high levels of kinesiophobia (TSK ≥ 37). This may negatively influence short-term recovery of these patients, by putting them at higher risk for falling and reduced functionality.

1 July 2019 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
TVTanmay Verlekar
Tanmay Verlekar
HVHenri De Vroey
Henri De Vroey
KCKurt Claeys
Kurt Claeys
HHHans Hallez
Hans Hallez
LSLUÍS DUCLA SOARES
LUÍS DUCLA SOARES
PCPaulo Lobato Correia
Paulo Lobato Correia

18 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MVMark Versteyhe
Mark Versteyhe
HVHenri De Vroey
Henri De Vroey
FDFrederik Debrouwere
Frederik Debrouwere
HHHans Hallez
Hans Hallez
KCKurt Claeys
Kurt Claeys
Traditional motion capture systems are the current standard in the assessment of knee joint kinematics. These systems are, however, very costly, complex to handle, and, in some conditions, fail to estimate the varus/valgus and internal/external rotation accurately due to the camera setup. This paper presents a novel and comprehensive method to infer the full relative motion of the knee joint, including the flexion/extension, varus/valgus, and internal/external rotation, using only low cost inertial measurement units (IMU) connected to the upper and lower leg. Furthermore, sensors can be placed arbitrarily and only require a short calibration, making it an easy-to-use and portable clinical analysis tool. The presented method yields both adequate results and displays the uncertainty band on those results to the user. The proposed method is based on an fixed interval smoother relying on a simple dynamic model of the legs and judicially chosen constraints to estimate the rigid body motion of the leg segments in a world reference frame. In this pilot study, benchmarking of the method on a calibrated robotic manipulator, serving as leg analogue, and comparison with camera-based techniques confirm the method’s accurateness as an easy-to-implement, low-cost clinical tool.