Numerous approaches have been taken to miniaturizing fluorescence sensing, which is a key capability for micro-total-analysis systems. This critical, comprehensive review focuses on the optical hardware required to attenuate excitation light while transmitting fluorescence. It summarizes, evaluates, and compares the various technologies, including filtering approaches such as interference filters and absorption filters and filterless approaches such as multicolor sensors and light-guiding elements. It presents the physical principles behind the different architectures, the state-of-the-art micro-fluorometers and how they were microfabricated, and their performance metrics. Promising technologies that have not yet been integrated are also described. This information will permit the identification of methods that meet particular design requirements, from both performance and integration perspectives, and the recognition of the remaining technological challenges. Finally, a set of performance metrics are proposed for evaluating and reporting spectral discrimination characteristics of integrated devices in order to promote side-by-side comparisons among diverse technologies and, ultimately, to facilitate optimized designs of micro-fluorometers for specific applications.
We report on the breakdown characteristics of a single-photon avalanche diode structure fabricated in a 0.5 μm single-well CMOS process. This paper features two mechanisms for reducing perimeter breakdown. The first mechanism consists of using the lateral diffusion of adjacent n-wells to reduce the electric field at the diode's periphery, and the second makes use of a poly-silicon gate over the high field regions to modulate the electric field. We studied each technique independently as well as their combined effect on the devices' avalanche profiles. In addition to marked alterations in the current-voltage curves near and above breakdown, the diodes' breakdown voltages were increased by more than 4 V, indicating that perimeter breakdown was curtailed. We verified this assertion through a self-consistently solved 2-D numerical model based on Poisson's equation and the hole and electron current continuity equations coupled with rate equations for carrier generation due to impact ionization. The model revealed spatial maxima of the charge generation rates, thereby indicating regions susceptible to breakdown. Our investigation revealed that in native diodes, the generation rate peaked at the perimeter and near the junction's surface, suggesting perimeter breakdown. Conversely, in devices where suppression techniques were used, the region of maximum generation spread laterally and away from the surface, indicating full volumetric breakdown was achieved.
This letter describes an avalanche photodiode (APD) fabricated in a 0.5-μm CMOS process. In Geiger mode, the APD had an area-normalized dark count rate as low as 2 Hz/μm2 at room temperature. Its signal-to-noise ratio (SNR) increased by an order of magnitude as a result of perimeter field gating. We demonstrate that under high-illumination conditions, perimeter field gating maximizes SNR, whereas under low-light conditions, it maximizes sensitivity.
21 March 2009 in IEEE Transactions on Biomedical Circuits and Systems
We describe the design, fabrication, and performance of a class of simple handheld fluorometers. The devices consist of a sensor along with an integrated optical filter packaged in a handheld format. The sensor is a differential active pixel sensor with in-pixel correlated double sampling fabricated in a 0.5-mu m 2-poly 3-metal complementary metal-oxide semiconductor process and has a readout noise of 175.3 muV, reset noise of 360 muV, dynamic range of 59 dB, and conversion gain of 530 nV/e- . The filter is a high rejection chromophore embedded in a polymer film which is cast onto the chip. We show the results of bioassays utilizing two different single color fluorometers constructed by using the chromophores 2-(2'-hydroxy 5'-methylphenyl) benzotriazole and Sudan II with long-pass wavelengths of 400 nm and 540 nm, respectively. The bioassays measures metabolic activity and viability of biological cells, which are useful for cytotoxicity and pathogen detection applications.
This paper features a model that allows the design and simulation of perimeter-gated single-photon avalanche diodes (SPADs). The model enables both Geiger mode and DC mode simulations. The model's key parameters were extracted from measured characteristics of a perimeter-gated SPAD fabricated in a 3-metal, 2-poly, single well CMOS process. This paper also features a survey of state-of-the-art SPAD models. Last, this paper describes the design and measured characteristics of a pixel that includes a perimeter-gated SPAD and a mixed-signal readout circuit.