Jong Woong Park

Dr. Jong Woong Park

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2021 in Cells
Verified
Journal Article
Open access
PDF file
JLJun Ah Lee
Jun Ah Lee
JLJiwon Lim
Jiwon Lim
HJHye Young Jin
Hye Young Jin
MPMeerim Park
Meerim Park
HPHyeon Jin Park
Hyeon Jin Park
YWYoung-Joo Won
Young-Joo Won
The epidemiology of osteosarcoma in adolescents and young adults (AYA) remains unclear. We aimed to assess and compare the clinical features of osteosarcoma between AYA and other age groups. We retrieved osteosarcoma cases diagnosed between 1999 and 2017 from the Korea Central Cancer Registry. We compared survival trends and clinical characteristics between AYA and other age groups. AYA comprised 43.3% (1309/3022) of the osteosarcoma cases. Compared to other age groups, the male-to-female ratio was highest in AYA (1.61:1). The proportion of tumors located in an extremity was 80.3% in AYA, which was lower than in young children (92.5%) or pubertal children (93.8%) but higher than in adults (55.7%) or the elderly (47.5%). As for treatments, 71.2% of AYA received local treatment and systemic chemotherapy, and 28.8% received only local treatment (surgery: 261, radiotherapy: 9, surgery and radiotherapy: 5). The 5-year overall survival (OS) was lower in AYA (68%) than in young children (78%) or pubertal children (73%) but higher than in adults (47%) or the elderly (25%). When AYA were divided into five subgroups by age, patients aged 15–19 years constituted the largest proportion (45.4%, n = 594). Additionally, the proportion of patients with a non-extremity tumor increased in an age-dependent manner, from 10.3% in AYA aged 15–19 years to 35.3% in AYA aged 35–39 years. OS did not significantly differ among the different age subgroups of AYA. The clinical characteristics and OS of the AYA were more similar to those of children than to those of adults. There is a need for cooperation between pediatric and adult oncologists for effective osteosarcoma treatment in AYA.

27 September 2018 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
PDF file
JPJong Woong Park
Jong Woong Park
HKHyun Guy Kang
Hyun Guy Kang
KLkwun mook lim
kwun mook lim
DPDae Woo Park
Dae Woo Park
JKJune Hyuk Kim
June Hyuk Kim
HKHan Soo Kim
Han Soo Kim

23 December 2021 in Clinical and Experimental Pediatrics
Verified
Journal Article
Open access
PDF file
JPJong Woong Park
Jong Woong Park
HKHyun Guy Kang
Hyun Guy Kang
Three-dimensional (3D) additive manufacturing has recently been used in various medical fields. Among them, orthopedic oncology is one that utilizes it most actively. Bone and tumor modeling for surgical planning, personalized surgical instrument fabrication, and implant fabrication are typical applications. The 3D-printed metal implants using titanium alloy powder have created a revolutionary change in bone reconstruction that can be customized to all body areas; however, bioprinting remains experimental and under active study. This review explores the practical applications of 3D printing in orthopedic oncology and presents a representative case. The 3D-printed implant can replace the conventional tumor prosthesis and auto/allobone graft, thereby personalizing bone reconstruction. Biologic bone reconstruction using biodegradable or bioprinted materials beyond metal may be possible in the future.

26 February 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DPDae Woo Park
Dae Woo Park
ALAekyeong Lim
Aekyeong Lim
JPJong Woong Park
Jong Woong Park
KLkwun mook lim
kwun mook lim
HKHyun Guy Kang
Hyun Guy Kang
Pelvic implants require complex geometrical shapes to reconstruct unusual areas of bone defects, as well as a high mechanical strength in order to endure high compressive loads. The electron beam melting (EBM) method is capable of directly fabricating complex metallic structures and shapes based on digital models. Fixation design is important during the 3D printing of pelvic implants, given that the fixation secures the pelvic implants to the remaining bones, while also bearing large amounts of the loads placed on the bone. In this study, a horseshoe-shaped plate fixation with a bridge component between two straight plates is designed to enhance the mechanical stability of pelvic implants. The aim of this study is to investigate the biomechanics of the horseshoe-shaped plate fixation in a 3D-printed pelvic implant using a finite element (FE) simulation. First, computed tomography (CT) scans were acquired from a patient with periacetabular bone tumors. Second, 3D FE implant models were created using the patient’s Digital Imaging and Communications in Medicine (DICOM) data. Third, a FE simulation was conducted and the stress distribution between a conventional straight-type plate model, and the horseshoe-shaped plate model was compared. In both of the models, high-stress regions were observed at the iliac fixation area. In contrast, minimal stress regions were located at the pubic ramus and ischium fixation area. The key finding of this study was that the maximal stress of the horseshoe-shaped plate model (38.6 MPa) was 21% lower than that of the straight-type plate model (48.9 MPa) in the iliac fixation area. The clinical potential for the application of the horseshoe-shaped plate fixation model to the pelvic implant has been demonstrated, although this is a pilot study.

11 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JPJong Woong Park
Jong Woong Park
CSChae Ahn Song
Chae Ahn Song
HKHyun Guy Kang
Hyun Guy Kang
JKJune Hyuk Kim
June Hyuk Kim
KLkwun mook lim
kwun mook lim
HKHan-Soo Kim
Han-Soo Kim
A titanium alloy implant of appropriate pore size can potentially enhance osseointegration and soft tissue integration. However, the human clinical application of such implants has not been reported. Here, we present a case of limb salvage surgery for a bone tumor using customized three-dimensional (3D)-printed Ti6Al4V radius and ulna implants. The patient presented with local recurrence at the proximal junction of the ulna and underwent a re-wide excision. Single forearm bone surgery was performed using another 3D-printed implant after resection of the recurrent tumor with an ulnar implant. Host osseointegration and soft tissue integration of the retrieved implant were quantified through histological evaluation. The total tissue integration rates of the implant at the proximal and distal bone junctions were 45.96% and 15.03%, respectively. The mesh structure enhanced bone integration by up to 10.81% in the proximal and by up to 8.91% in the distal bone junction. Furthermore, the soft tissue adhesion rates of the implant shaft were 59.50% and 50.26% in the axial and longitudinal cuts, respectively. No area was left unoccupied throughout the shaft of the implant. Overall, these results indicate that the 3D-printed Ti6Al4V titanium alloy implant with a rough surface has considerable tissue integration ability.

14 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JPJong Woong Park
Jong Woong Park
HPHyenmin Park
Hyenmin Park
JKJune Hyuk Kim
June Hyuk Kim
HKHong Moule Kim
Hong Moule Kim
CYChang Hyoung Yoo
Chang Hyoung Yoo
HKHyun Guy Kang
Hyun Guy Kang
Lattice structures for implants can be printed using metal three-dimensional (3D)-printing and used as a porous microstructures to enhance bone ingrowth as orthopedic implants. However, designs and 3D-printed products can vary. Thus, we aimed to investigate whether targeted pores can be consistently obtained despite printing errors. The cube-shaped specimen was printed with one side 15 mm long and a full lattice with a dode-thin structure of 1.15, 1.5, and 2.0 mm made using selective laser melting. Beam compensation was applied, increasing it until the vector was lost. For each specimen, the actual unit size and strut thickness were measured 50 times. Pore size was calculated from unit size and strut thickness, and porosity was determined from the specimen’s weight. The actual average pore sizes for 1.15, 1.5, and 2.0 mm outputs were 257.9, 406.2, and 633.6 μm, and volume porosity was 62, 70, and 80%, respectively. No strut breakage or gross deformation was observed in any 3D-printed specimens, and the pores were uniformly fabricated with < 10% standard deviation. The actual micrometer-scaled printed structures were significantly different to the design, but this error was not random. Although the accuracy was low, precision was high for pore cells, so reproducibility was confirmed.