Anna Iliadi

Dr. Anna Iliadi

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Journal of Dentistry
Verified
Journal Article
Closed access
AIAnna Iliadi
Anna Iliadi
DKDimitrios Kloukos
Dimitrios Kloukos
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
CKChristos Katsaros
Christos Katsaros
NPNikolaos Pandis
Nikolaos Pandis

25 June 2019 in Orthodontics & Craniofacial Research
Verified
Journal Article
Closed access
PDF file
AIAnna Iliadi
Anna Iliadi
Despina KoletsiDespina Koletsi
Despina Koletsi
TETheodore Eliades
Theodore Eliades

14 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
AIAnna Iliadi
Anna Iliadi
Despina KoletsiDespina Koletsi
Despina Koletsi
Spyridon N. PapageorgiouSpyridon N. Papageorgiou
Spyridon N. Papageorgiou
Theodore EliadesTheodore Eliades
Theodore Eliades
Use of thermoplastic material in orthodontics, either as aligner or as retainer appliances, is common practice and is likely to increase in the years to come. However, no systematic assessment on safety considerations of these adjuncts has been implemented up to date. The aim of this systematic review was to collectively appraise the existing evidence from both clinical and laboratory studies, on whether these appliances are associated with any estrogenic/cytotoxic effects or bisphenol-A (BPA) and monomer leaching. Eight electronic databases were searched with no limits in December 22, 2019, for published and unpublished research. Eligibility criteria comprised of studies of any design, describing use of any type of thermoplastic aligner. Study selection, data extraction and risk of bias (RoB) assessment was done independently, either in duplicate or confirmed by a second reviewer. Random effects meta-analyses of weighted mean differences (WMD) with associated 95% Confidence Intervals (CIs) were planned. Quality of the evidence was evaluated with Grading of Recommendations Assessment, Development and Evaluation (GRADE). A total of 58 articles were initially identified, while 5 were included in qualitative synthesis and 2 of those contributed to the quantitative syntheses. Four studies were in-vitro, while one was a randomized controlled trial; all assessed some type of orthodontic aligner or retainer, either as-received or retrieved. Risk of bias recordings ranged between unclear and high for all studies. Proliferation induction capacity of thermoplastic appliances’ eluents on MCF-7 cells failed to be confirmed compared to beta-estradiol (2 studies: 5% v/v, WMD: −182.08; 95% CI: −198.83, −165.33; p-value < 0.001; and 20% v/v, WMD: −184.53; 95% CI: −206.17, −162.88; p-value < 0.001). No cytotoxic activity was detected as well. In addition, although evidence from in-vitro studies was indicative of no traceable detection of BPA or other monomers, the findings from a single clinical trial were allied to increased levels of BPA in whole stimulated saliva, after up to 30 days of thermoplastic retainer usage, compared to standard Hawley retainer. The quality of the evidence overall was low to medium. Current data from in-vitro research are indicative of an absence of an estrogenic or cytotoxic effect of thermoplastic aligners or retainers. Regarding BPA or monomer release, evidence from clinical and laboratory studies appear inconsistent.

10 February 2015 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
SBStefan Baumgartner
Stefan Baumgartner
AIAnna Iliadi
Anna Iliadi
Theodore EliadesTheodore Eliades
Theodore Eliades
GEORGE ELIADESGEORGE ELIADES
GEORGE ELIADES
The aim of the present study was to assess the changes in enamel roughness parameters before and after stripping with an oscillating diamond strip system. Sound premolars extracted for orthodontic reasons were embedded up to their cervical area in a polyvinylsiloxane putty, creating four groups of four teeth with three interproximal areas each (mesial/distal). The same regions of interproximal enamel surfaces were studied by 3D optical interferometric profilometry before and after stripping with the Ortho-Strips system (Intensiv Dental SA, Montagnola, Switzerland) (n teeth = 16, n contact points = 12, n sites measured = 24). The roughness parameters tested were the amplitude parameters Sa and Sz, the hybrid parameter Sdr, and the functional parameters Sci and Svi. The parameter differences (ΔSa, ΔSz, ΔSdr, ΔSci, ΔSvi) were calculated per region and statistically analyzed by one-sample Mann-Whitney rank sum test (a = 0.05). High statistically significant differences were found in ΔSa, ΔSz, and ΔSvi median values (0.453, 3.870, and 0.040 μm, respectively); a significant difference in ΔSdr median value (1.514%); and no statistically significant difference in ΔSci (0.110 median value). Under the conditions of the present study, the Ortho-Strips system seems to significantly increase the amplitude parameters Sa and Sz; the hybrid parameter Sdr, associated with the developed interfacial area ratio; and the functional parameter Svi, which depicts the volume of the deepest valleys. Under the conditions of the present study, the Ortho-Strips seems to significantly increase four of five measured roughness parameters.

31 October 2019 in Materials
Verified
Journal Article
Open access
PDF file
Despina KoletsiDespina Koletsi
Despina Koletsi
AIAnna Iliadi
Anna Iliadi
Theodore EliadesTheodore Eliades
Theodore Eliades
GEORGE ELIADESGEORGE ELIADES
GEORGE ELIADES
Tooth wear may be described as a side-effect of occlusal forces that may be further induced by the common use of contemporary prosthetic materials in practice. The purpose of this systematic review was to appraise existing evidence on enamel wear from both in vitro and clinical research and explore whether evidence from these study designs lies on the same direction. Five databases of published and unpublished research were searched without limitations in August 2019 and study selection criteria included in vitro and clinical research on enamel tooth wear. Study selection, data extraction, and risk of bias assessment were done independently and in duplicate. Random effects meta-analyses of standardized mean differences (SMDs) or weighted mean differences (WMDs) with 95% confidence intervals (CIs) were conducted while a Monte Carlo permutation test for meta-regression on the exploration of the effect of the study design on the reported outcomes was planned. A total of 27 studies (23 in vitro and 4 clinical) were eligible while 12 contributed to meta-analyses. Overall, some concerns were raised for the quality of the existing evidence and the potential for risk of bias. Enamel wear (mm) of antagonist teeth was more pronounced when opposed to conventional porcelain compared to machinable ceramics (SMD = 2.18; 95%CIs: 1.34, 3.02; p < 0.001). Polished zirconia resulted in decreased volumetric enamel wear (mm3) of opposing teeth compared to pure natural enamel (SMD = –1.06; 95%CIs: –1.73, –0.39; p = 0.002). Monolithic zirconia showed evidence of enhanced potential for antagonist wear (μm) compared to natural teeth (WMD = 107.38; 95%CIs: 30.46, 184.30; p = 0.01). Study design did not reveal an effect on the tooth wear outcome for the latter comparison when both clinical and in vitro studies were considered (three studies; Monte Carlo test, p = 0.66). In conclusion, there is an overriding need for additional evidence from clinical research to substantiate the findings from the already existing laboratory simulation studies.

31 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
AIAnna Iliadi
Anna Iliadi
Despina KoletsiDespina Koletsi
Despina Koletsi
Theodore EliadesTheodore Eliades
Theodore Eliades
GEORGE ELIADESGEORGE ELIADES
GEORGE ELIADES
Composite dust generation is most likely a continuous and daily procedure in dental practice settings. The aim of this systematic review was to identify, compile and evaluate existing evidence on interventions and composite material properties related to the production of aerosolized dust during routine dental procedures. Seven electronic databases were searched, with no limits, supplemented by a manual search, on 27 April 2020 for published and unpublished research. Eligibility criteria comprised of studies of any design, describing composite dust production related to the implementation of any procedure in dental practice. Study selection, data extraction and risk of bias (RoB) assessment was undertaken independently either in duplicate, or confirmed by a second reviewer. Random effects meta-analyses of standardized mean differences (SMD) with associated 95% confidence intervals (CIs) were employed where applicable. A total of 375 articles were initially identified, resulting in 13 articles being included in the qualitative synthesis, of which 5 contributed to meta-analyses overall. Risk of bias recordings ranged between low and high, pertaining to unclear/raising some concerns, in most cases. All types of composites, irrespective of the filler particles, released significant amounts of nano-sized particles after being ground, with potentially disruptive respiratory effects. Evidence supported increased % distribution of particles < 100 nm for nanocomposite Filtek Supreme XTE compared to both conventional hybrid Z100MP (SMD: 1.96, 95% CI: 0.85, 3.07; p-value; 0.001) and nano- hybrid Tetric EvoCeram (SMD: 1.62, 95% CI: 0.56, 2.68; p-value: 0.003). For cytotoxicity considerations of generated aerosolized particles, both nanocomposites Filtek Supreme XTE and nanohybrid GradiO revealed negative effects on bronchial epithelial cell viability, as represented by % formazan reduction at 330–400 μg/mL for 24 hours, with no recorded differences between them (SMD: 0.19; 95% CI: −0.17, 0.55; p-value: 0.30). Effective and more rigorous management of dental procedures potentially liable to the generation of considerable amounts of aerosolized composite dust should be prioritized in contemporary dental practice. In essence, protective measures for the clinician and the practices’ personnel should also be systematically promoted and additional interventions may be considered in view of the existing evidence.