1 February 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
MNMinh Ngoc Nguyen
Minh Ngoc Nguyen
NHNhat Sinh Ha
Nhat Sinh Ha
LNLong Quang Nguyen
Long Quang Nguyen
CHChu Hoang
Chu Hoang
HVHung Ngoc Vu
Hung Ngoc Vu
This paper reports on the design and fabrication of a z-axis tuning fork gyroscope which has a freestanding architecture. In order to improve the performance of the tuning fork gyroscope by eliminating the influence of the squeeze-film air damping, the driving and sensing parts of the gyroscope were designed to oscillate in-plane. Furthermore, by removing the substrate underneath the device, the slide-film air damping in the gap between the proof masses and the substrate was eliminated. The proposed architecture was analyzed by the finite element method using ANSYS software. The simulated frequencies of the driving and sensing modes were 9.788 and 9.761 kHz, respectively. The gyroscope was fabricated using bulk micromachining technology. The quality factor and sensitivity of the gyroscope operating in atmospheric conditions were measured to be 111.2 and 11.56 mV/°/s, respectively.

18 September 2019 in Advanced Optical Materials
Verified
Journal Article
Closed access
PDF file
KWKaiyu Wu
Kaiyu Wu
LNLong Quang Nguyen
Long Quang Nguyen
TRTomas Rindzevicius
Tomas Rindzevicius
SKStephan Sylvest Keller
Stephan Sylvest Keller
ABAnja Boisen
Anja Boisen

1 July 2018 in Carbon
Verified
Journal Article
Closed access
LNLong Quang Nguyen
Long Quang Nguyen
PLPeter Emil Larsen
Peter Emil Larsen
ABAnja Boisen
Anja Boisen
SKStephan Sylvest Keller
Stephan Sylvest Keller

21 October 2019 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
LNLong Quang Nguyen
Long Quang Nguyen
PLPeter Emil Larsen
Peter Emil Larsen
TLTom Larsen
Tom Larsen
SGSanjukta Bose Goswami
Sanjukta Bose Goswami
Luis Guillermo VillanuevaLuis Guillermo Villanueva
Luis Guillermo Villanueva
SKStephan Sylvest Keller
Stephan Sylvest Keller
Thermal analysis is essential for the characterization of polymers and drugs. However, the currently established methods require a large amount of sample. Here, we present pyrolytic carbon resonators as promising tools for micromechanical thermal analysis (MTA) of nanograms of polymers. Doubly clamped pre-stressed beams with a resonance frequency of 233 ± 4 kHz and a quality factor (Q factor) of 800 ± 200 were fabricated. Optimization of the electrical conductivity of the pyrolytic carbon allowed us to explore resistive heating for integrated temperature control. MTA was achieved by monitoring the resonance frequency and quality factor of the carbon resonators with and without a deposited sample as a function of temperature. To prove the potential of pyrolytic carbon resonators as thermal analysis tools, the glass transition temperature (Tg) of semicrystalline poly(L-lactic acid) (PLLA) and the melting temperature (Tm) of poly(caprolactone) (PCL) were determined. The results show that the Tg of PLLA and Tm of PCL are 61.0 ± 0.8 °C and 60.0 ± 1.0 °C, respectively, which are in excellent agreement with the values measured by differential scanning calorimetry (DSC).

1 March 2019 in Micro and Nano Engineering
Verified
Journal Article
Open access
LNLong Quang Nguyen
Long Quang Nguyen
Arnab HalderArnab Halder
Arnab Halder
Babak RezaeiBabak Rezaei
Babak Rezaei
PLPeter Emil Larsen
Peter Emil Larsen
YSYi Sun
Yi Sun
SKStephan Sylvest Keller
Stephan Sylvest Keller

26 October 2013 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
TTThong Quang Trinh
Thong Quang Trinh
LNLong Quang Nguyen
Long Quang Nguyen
Dzung DaoDzung Dao
Dzung Dao
CHChu Hoang
Chu Hoang
HVHung Ngoc Vu
Hung Ngoc Vu