Jaeman Lim

Jaeman Lim

Auto-generated profile, based on publicly available information

Jaeman Lim

Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
YJYei Hwan Jung
Yei Hwan Jung
JYJae-Young Yoo
Jae-Young Yoo
Abraham Vázquez-GuardadoAbraham Vázquez-Guardado
Abraham Vázquez-Guardado
JKJae-Hwan Kim
Jae-Hwan Kim
JKJin-Tae Kim
Jin-Tae Kim
John A. RogersJohn A. Rogers
John A. Rogers

10 April 2023 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
KKKyeongha Kwon
Kyeongha Kwon
JKJong Uk Kim
Jong Uk Kim
SWSang Min Won
Sang Min Won
JZJianzhong Zhao
Jianzhong Zhao
RARaudel Avila
Raudel Avila
John A. RogersJohn A. Rogers
John A. Rogers

24 August 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
YOYong Suk Oh
Yong Suk Oh
JKJae-Hwan Kim
Jae-Hwan Kim
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
SCSeokjoo Cho
Seokjoo Cho
HHHyeonseok Han
Hyeonseok Han
John A. RogersJohn A. Rogers
John A. Rogers
Capabilities for continuous monitoring of pressures and temperatures at critical skin interfaces can help to guide care strategies that minimize the potential for pressure injuries in hospitalized patients or in individuals confined to the bed. This paper introduces a soft, skin-mountable class of sensor system for this purpose. The design includes a pressure-responsive element based on membrane deflection and a battery-free, wireless mode of operation capable of multi-site measurements at strategic locations across the body. Such devices yield continuous, simultaneous readings of pressure and temperature in a sequential readout scheme from a pair of primary antennas mounted under the bedding and connected to a wireless reader and a multiplexer located at the bedside. Experimental evaluation of the sensor and the complete system includes benchtop measurements and numerical simulations of the key features. Clinical trials involving two hemiplegic patients and a tetraplegic patient demonstrate the feasibility, functionality and long-term stability of this technology in operating hospital settings.

22 May 2024 in Nature
Verified
Journal Article
Closed access
PDF file
SKSun Hong Kim
Sun Hong Kim
ABAbdul Basir
Abdul Basir
RARaudel Avila
Raudel Avila
JLJaeman Lim
Jaeman Lim
SHSeong Woo Hong
Seong Woo Hong
YJYei Hwan Jung
Yei Hwan Jung

4 December 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
SMSurabhi R. Madhvapathy
Surabhi R. Madhvapathy
HWHeling Wang
Heling Wang
JKJessy Kong
Jessy Kong
MZMichael Zhang
Michael Zhang
JLJong Yoon Lee
Jong Yoon Lee
John A. RogersJohn A. Rogers
John A. Rogers
Present-day dermatological diagnostic tools are expensive, time-consuming, require substantial operational expertise, and typically probe only the superficial layers of skin (~15 μm). We introduce a soft, battery-free, noninvasive, reusable skin hydration sensor (SHS) adherable to most of the body surface. The platform measures volumetric water content (up to ~1 mm in depth) and wirelessly transmits data to any near-field communication–compatible smartphone. The SHS is readily manufacturable, comprises unique powering and encapsulation strategies, and achieves high measurement precision (±5% volumetric water content) and resolution (±0.015°C skin surface temperature). Validation on n = 16 healthy/normal human participants reveals an average skin water content of ~63% across multiple body locations. Pilot studies on patients with atopic dermatitis (AD), psoriasis, urticaria, xerosis cutis, and rosacea highlight the diagnostic capability of the SHS (PAD = 0.0034) and its ability to study impact of topical treatments on skin diseases.

20 May 2024 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
JKJae-Hwan Kim
Jae-Hwan Kim
Abraham Vázquez-GuardadoAbraham Vázquez-Guardado
Abraham Vázquez-Guardado
HLHaiwen Luan
Haiwen Luan
JKJin-Tae Kim
Jin-Tae Kim
DYDa Som Yang
Da Som Yang
John A. RogersJohn A. Rogers
John A. Rogers
Sensations of heat and touch produced by receptors in the skin are of essential importance for perceptions of the physical environment, with a particularly powerful role in interpersonal interactions. Advances in technologies for replicating these sensations in a programmable manner have the potential not only to enhance virtual/augmented reality environments but they also hold promise in medical applications for individuals with amputations or impaired sensory function. Engineering challenges are in achieving interfaces with precise spatial resolution, power-efficient operation, wide dynamic range, and fast temporal responses in both thermal and in physical modulation, with forms that can extend over large regions of the body. This paper introduces a wireless, skin-compatible interface for thermo-haptic modulation designed to address some of these challenges, with the ability to deliver programmable patterns of enhanced vibrational displacement and high-speed thermal stimulation. Experimental and computational investigations quantify the thermal and mechanical efficiency of a vertically stacked design layout in the thermo-haptic stimulators that also supports real-time, closed-loop control mechanisms. The platform is effective in conveying thermal and physical information through the skin, as demonstrated in the control of robotic prosthetics and in interactions with pressure/temperature-sensitive touch displays.