An innovative control strategy for adaptive secondary frequency regulation utilizing dynamic energy storage based on primary frequency response is proposed. This strategy is inactive when the system frequency remains within a predetermined frequency deviation threshold, whereby only the primary frequency regulation is executed through a combination of virtual droop and virtual inertia. The droop coefficient is dynamically related to both the state of charge (SOC) of the energy storage and the frequency deviation, adapting in response to these parameters. If the system frequency deviation exceeds, the integration link will be activated based on the energy storage participating in the primary frequency regulation of the power grid. This activation facilitates a segmented adaptive adjustment of the integral coefficient in accordance with the dynamic characteristics of system frequency variations observed during the regulation process. Additionally, the droop coefficient is incorporated as a modifying factor into the integral coefficient to enhance the control during secondary frequency regulation until all steady-state errors are mitigated. Disengagement from the secondary frequency regulation not only accelerates the restoration of grid frequency but also ensures precise and error-free adjustment of the system frequency, thereby improving tracking and dynamic performance. The effectiveness of the proposed control strategy is demonstrated through simulation.
4 January 2023 in IEEE Transactions on Industrial Electronics
A nonlinear multimode controller is proposed to achieve the whole process seamless off-grid of energy storage inverter (ESI) from the grid-connected state of current control mode to the islanded state of voltage control mode under unintentional islanding. Based on the presented design idea of intelligent equivalent substitution, NMC is composed of multimode voltage controller (MVC), multimode power compensator (MPC), and multimode current controller (MCC). MVC can control load voltage in islanding and maintain manipulated variables of load current in other modes. MPC can compensate the power flowing into grid and help inner loop reference value achieve the smooth drop, and also compensate for load current variation during grid connection. MCC can track the given current during grid-connection and make MPC quickly obtain the compensation of load power variation. The reference values of inner loop are logically split into the output of MVC, MPC, and MCC, so that the manipulated variables can be combined nonlinearly to achieve seamless off-grid of ESI under unintentional islanding. This article also analyzes the ESI stability with NMC during the off-grid process, and analyzes the relationship between manipulated variables by simulations. Finally, the correctness and effectiveness of proposed NMC are verified by experiments.
The island microgrid is composed of a large number of inverters and various types of power equipment, and the interaction between inverters with different control methods may cause system instability, which will cause the power equipment to malfunction. Therefore, effective methods for analyzing the stability of the microgrid system have become particularly important. Generally, impedance modeling methods are used to analyze the stability of power electronic converter systems. In this paper, the impedance models of a PQ-controlled inverter and droop-controlled inverter are established in d-q frame. In view of the difference of output characteristics between the two control methods, the island microgrid is equivalent to a double closed-loop system. The impedance model of the parallel system is derived and the open loop transfer function of the system is extracted. Based on the generalized Nyquist criterion (GNC), the stability of parallel system working in island microgrid mode is analyzed using this proposed impedance model. The simulation and experiment results are presented to verify the analysis.
The rapid integration of inverter-based resources (IBRs) into power systems has identified frequency security challenges due to reduced inertia and increased load volatility. This paper proposes a robust power reserve decision-making approach for dynamic virtual power plants (DVPPs) to address these challenges, especially under temporally sequential and uncertain disturbances. An analytical model is developed to characterize the system's frequency response dynamics, enabling the quantification of virtual inertia and virtual damping requirements to meet rate-of-change-of-frequency (RoCoF), frequency nadir, and steady-state deviation constraints. By analytically deriving the regulation power dynamics, the required virtual inertia and damping parameters for the DVPP are determined in a robust way. Then, the total power reserve decision is made by optimally allocating the parameters and calculating the actual power reserves for IBRs, fully considering their economic diversity. Finally, case studies conducted on an IEEE nine-bus system demonstrate the effectiveness of the proposed approach. The results indicate the high reliability of the proposed approach in ensuring frequency security.
17 February 2025 in IEEE Transactions on Energy Conversion
In this paper, an intelligent coordinated control scheme is proposed for the full-mode smooth operation of the parallel energy storage system (ESS). The proposed scheme includes a power intelligent control loop and a voltage and current coordinated control loop. The intelligent power control loop can automatically adjust the ESS to grid-following control or grid-forming control to obtain optimal operation according to the grid-connected or islanded mode. The voltage and current coordinated control loop can automatically coordinate the gain of the controller during the mode transition between grid-connected and islanded modes, so as to achieve smooth mode transition. Especially for the unintentional islanding, the proposed intelligent limiter can adaptively adjust the limiting value to obtain the optimal voltage reference, so that ESS can quickly respond to the optimal voltage control. The proposed scheme can significantly reduce the voltage and power impact caused by conventional unintentional islanding, thus ensuring the smooth off-grid of the system. The mechanism analysis and parameter design of the proposed scheme are carried out. Finally, the experimental results show that the proposed scheme can achieve the full-mode smooth operation of grid-connection and islanding and their mutual transition.