Chunjiang Zhang

Prof. Dr. Chunjiang Zhang

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2020 in Electronics
Verified
Journal Article
Open access
PDF file
CZChunjiang Zhang
Chunjiang Zhang
PLPengcheng Li
Pengcheng Li
YGYingjun Guo
Yingjun Guo
In DC microgrids, distributed energy storage plays a key role in stabilizing the DC bus voltage. The bidirectional DC/DC converter in the distributed energy storage system should be designed according to the voltage level and electromagnetic isolation requirements, and multiple energy storage units should be coordinated for load current distribution according to the state of charge (SOC). This paper proposes a SOC power index droop control strategy by communication lines to coordinate the fast and high-precision distribution of load current among multiple energy storage units, and the SOC between energy storage units quickly converges to a consistent state. Considering that communication lines are susceptible to interference, this paper further proposes an improved SOC power index droop control to overcome the effects of communication line failures. Considering the high cost of the energy storage unit, it should be connected to the DC microgrid in layers to achieve a reasonable allocation of resources in practical applications. In order to provide high-quality power to a large power grid, the quantification standards of the DC bus fluctuation range and the working range of each converter are further discussed to maximize the stability of the DC bus voltage and grid-connected power fluctuation.

4 January 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HQHongyang Qing
Hongyang Qing
CZChunjiang Zhang
Chunjiang Zhang
JXJingyuan Xu
Jingyuan Xu
SZSonglin Zeng
Songlin Zeng
XGXiaoqiang Guo
Xiaoqiang Guo
A nonlinear multimode controller is proposed to achieve the whole process seamless off-grid of energy storage inverter (ESI) from the grid-connected state of current control mode to the islanded state of voltage control mode under unintentional islanding. Based on the presented design idea of intelligent equivalent substitution, NMC is composed of multimode voltage controller (MVC), multimode power compensator (MPC), and multimode current controller (MCC). MVC can control load voltage in islanding and maintain manipulated variables of load current in other modes. MPC can compensate the power flowing into grid and help inner loop reference value achieve the smooth drop, and also compensate for load current variation during grid connection. MCC can track the given current during grid-connection and make MPC quickly obtain the compensation of load power variation. The reference values of inner loop are logically split into the output of MVC, MPC, and MCC, so that the manipulated variables can be combined nonlinearly to achieve seamless off-grid of ESI under unintentional islanding. This article also analyzes the ESI stability with NMC during the off-grid process, and analyzes the relationship between manipulated variables by simulations. Finally, the correctness and effectiveness of proposed NMC are verified by experiments.

26 February 2018 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
XZXiaojun Zhao
Xiaojun Zhao
CZChunjiang Zhang
Chunjiang Zhang
XCXiuhui Chai
Xiuhui Chai
JZJinlong Zhang
Jinlong Zhang
FLFanqi Liu
Fanqi Liu
ZZZhe Zhang
Zhe Zhang
In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the control precision as well as the performance of the three-phase four-wire unified power quality conditioner (UPQC), and it also leads to unbalanced three-phase output voltage, even causing damage to electric equipment. To deal with unbalanced loads, this paper proposes a matching-ratio compensation algorithm (MCA) for the fundamental active component of load currents, and by employing this MCA, balanced three-phase grid currents can be realized under 100% unbalanced loads. The steady-state fluctuation and the transient drop of the DC bus voltage can also be restrained. This paper establishes the mathematical model of the UPQC, analyzes the mechanism of the DC bus voltage fluctuations, and elaborates the interaction between unbalanced grid currents and DC bus voltage fluctuations; two control strategies of UPQC under three-phase stationary coordinate based on the MCA are given, and finally, the feasibility and effectiveness of the proposed control strategy are verified by experiment results.

10 March 2020 in Electronics
Verified
Journal Article
Open access
PDF file
XWXiaohuan Wang
Xiaohuan Wang
HQHongyang Qing
Hongyang Qing
PHPeng Huang
Peng Huang
CZChunjiang Zhang
Chunjiang Zhang
The island microgrid is composed of a large number of inverters and various types of power equipment, and the interaction between inverters with different control methods may cause system instability, which will cause the power equipment to malfunction. Therefore, effective methods for analyzing the stability of the microgrid system have become particularly important. Generally, impedance modeling methods are used to analyze the stability of power electronic converter systems. In this paper, the impedance models of a PQ-controlled inverter and droop-controlled inverter are established in d-q frame. In view of the difference of output characteristics between the two control methods, the island microgrid is equivalent to a double closed-loop system. The impedance model of the parallel system is derived and the open loop transfer function of the system is extracted. Based on the generalized Nyquist criterion (GNC), the stability of parallel system working in island microgrid mode is analyzed using this proposed impedance model. The simulation and experiment results are presented to verify the analysis.

6 February 2023 in Journal of Power Electronics
Verified
Journal Article
Closed access
PDF file
HQHongyang Qing
Hongyang Qing
CZChunjiang Zhang
Chunjiang Zhang
XCXiuhui Chai
Xiuhui Chai
HHHao He
Hao He
XWXiaohuan Wang
Xiaohuan Wang

8 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
XZXiaojun Zhao
Xiaojun Zhao
XCXiuhui Chai
Xiuhui Chai
XGXiaoqiang Guo
Xiaoqiang Guo
AWAhmad Waseem
Ahmad Waseem
XWXiaohuan Wang
Xiaohuan Wang
CZChunjiang Zhang
Chunjiang Zhang
Different from the extant power flow analysis methods, this paper discusses the power flows for the unified power quality conditioner (UPQC) in three-phase four-wire systems from the point of view of impedance matching. To this end, combined with the designed control strategies, the establishing method of the UPQC impedance model is presented, and on this basis, the UPQC system can be equivalent to an adjustable impedance model. After that, a concept of impedance matching is introduced into this impedance model to study the operation principle for the UPQC system, i.e., how the system changes its operation states and power flow under the grid voltage variations through discussing the matching relationships among node impedances. In this way, the nodes of the series and parallel converter are matched into two sets of impedances in opposite directions, which mean that one converter operates in rectifier state to draw the energy and the other one operates in inverter state to transmit the energy. Consequently, no matter what grid voltages change, the system node impedances are dynamically matched to ensure that output equivalent impedances are always equal to load impedances, so as to realize impedance and power balances of the UPQC system. Finally, the correctness of the impedance matching-based power flow analysis is validated by the experimental results.