Fan Cheng

Dr. Fan Cheng

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
JDJunpeng Deng
Junpeng Deng
FCFan Cheng
Fan Cheng
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
JXJian Xu
Jian Xu
BMBeilin Mao
Beilin Mao
RCRusi Chen
Rusi Chen
Offshore wind farm (OWF) is considered as a perfect zero‐carbon energy source for the future power system. However, the growing offshore distance and water depth of OWF make the OWF HVDC transmission technique a more promising solution than HVAC due to higher cost‐efficiency and reliability. In this paper, the current situation of OWF‐HVDC projects is introduced at first. Then, novel converter topologies with the higher power density and cost‐efficiency are presented, including the hybrid modular multilevel converter (MMC), alternative arm converter (AAC), and diode rectifier (DR). Next, several OWF HVDC transmission system topologies are introduced, including terminal‐hybrid, station‐hybrid and all‐DC delivered system. Furthermore, the key technologies for OWF HVDC operation and control are summarized, including grid‐forming control strategy for offshore wind turbines, stability analysis method, corresponding stability enhancement measures and frequency support control strategies. Additionally, the fault ride‐through and protection strategies for different fault locations have been presented. Finally, the main conclusions and prospects for OWF HVDC are summarized.

19 March 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YLYunxin Liu
Yunxin Liu
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
Siyang LiaoSiyang Liao
Siyang Liao
XJXu Jian
Xu Jian
FCFan Cheng
Fan Cheng
One of the main characteristics of power systems with a high proportion of renewable energy is that the power system is becoming a power system with a high proportion of voltage source converters (VSCs). Owing to the current limitation of VSCs, the reactive power regulation range is limited, thus greatly weakening the effective reactive power reserve and reducing the static voltage stability. In this paper, the PQ regulation characteristics of the VSC are first analyzed considering the current limitation. By establishing the PQ characteristic analytical model of a single grid-connected VSC system, the changes in the system reactive power reserve and system static voltage stability evolution law under different penetration ratios of VSCs are analyzed. On this basis, according to the proposed reactive power support sensitivity of each source bus, it is proposed to optimally determine the voltage and effective reactive power reserve of each source bus to realize effective enhancement of the static voltage stability margin of the power system with a high proportion of VSCs. Simulation analyses are carried out in a system with multiple grid-connected VSCs and an extended IEEE-39 bus system, which validate the effectiveness and accuracy of the proposed method.

9 November 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
QSQianhao Sun
Qianhao Sun
QSQiang Song
Qiang Song
JMJingwei Meng
Jingwei Meng
BCBin Cui
Bin Cui
Gen LiGen Li
Gen Li
KWKailun Wang
Kailun Wang
A new grid-forming (GFM) high-voltage direct current (HVdc) rectifier, named flexible line-commutated converter (Flex-LCC), is proposed in this article to collect the power generated by large-scale islanded or weak-grid-supported renewable energy systems. The Flex-LCC uses a series-connected hybrid valve based on the LCC and full-bridge modular multilevel converter (FBMMC), and adopts a new control. As a result, the Flex-LCC works as a GFM rectifier and retains the same dc voltage and power carrying capacity, dc fault clearing, and power reversal functions as an LCC. Particularly, the Flex-LCC has three salient features: the control of the Flex-LCC is decoupled from the LCC part's firing angle, the internal reactive power allocation is flexible, and the valve-side ac voltage of the FBMMC part has a wide operation range due to the decoupling of dc-port voltage and capacitor voltage. These bring reduced interharmonics, enhanced stability, and a smaller capacity boundary to the FBMMC part for the Flex-LCC. Furthermore, utilizing the reasonable design for the actual capacity and valve-side ac voltage of the FBMMC, the Flex-LCC can effectively balance cost, footprint, and weight, and match the current-carrying capacity between the series-connected LCC and FBMMC. The topology, control, characteristics, and design of the Flex-LCC are analyzed in detail in this article. Simulations and experiments validate the theory.

17 October 2022 in Energy Reports
Verified
Journal Article
Open access
QLQingsheng Li
Qingsheng Li
YZYu Zhang
Yu Zhang
FCFan Cheng
Fan Cheng
LYLiangzhong Yao
Liangzhong Yao
YXYeyan Xu
Yeyan Xu
ZLZhen Li
Zhen Li

1 January 2021 in Strategic Study of CAE
Verified
Journal Article
Closed access
HHHaixia Huang
Haixia Huang
FCFan Cheng
Fan Cheng
YSYinao Su
Yinao Su
LYLiangzhong Yao
Liangzhong Yao
JHJianzu Hu
Jianzu Hu
Energy-saving and efficiency improvement, energy intensity, energy-saving potential analysis, energy resource structure,industry reconstructing

28 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
LXLijun Xie
Lijun Xie
FCFan Cheng
Fan Cheng
JWJing Wu
Jing Wu
The DR-HVDC (Diode rectifier-based HVDC) transmission topology was recently proposed for integration on large offshore wind farms due to its low investment cost and high reliability. To further reduce the investment, a DC collection topology based on the series-connected diode rectifiers (DR) is proposed, where no offshore platform is needed. However, units of series-connected topology (SCU) show coupling issues, such as overvoltage, energy curtailment, and fault isolation. First, the coupling mechanism is analyzed, and a suitable operation mode for SCUs is selected to ensure the safe operation of the DC system. Then, the linear relationship of active power and output DC current and DC voltage of SCUs is analyzed, and a novel coordinate control strategy for DC wind farms is proposed, where an onshore converter adapts a DC current controller and wind turbines adapt a mediate output voltage control strategy. The mediate output voltage control strategy includes a triple loop with power loop, mediate output voltage loop, and current loop. Also, the DC open line fault, DC grounding fault, and AC grounding fault of the onshore grid are investigated, and a protection strategy is proposed. A 160 MW wind farm with a DR-SCU DC collection system is built in PSCAD/EMTDC to verify the validity of the proposed control strategy under unequal wind speeds, DC fault, and onshore AC fault, and the results validate the performance of the proposed strategy.