Junpeng Deng

Mr. Junpeng Deng

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2023 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
JDJunpeng Deng
Junpeng Deng
FCFan Cheng
Fan Cheng
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
JXJian Xu
Jian Xu
BMBeilin Mao
Beilin Mao
RCRusi Chen
Rusi Chen
Offshore wind farm (OWF) is considered as a perfect zero‐carbon energy source for the future power system. However, the growing offshore distance and water depth of OWF make the OWF HVDC transmission technique a more promising solution than HVAC due to higher cost‐efficiency and reliability. In this paper, the current situation of OWF‐HVDC projects is introduced at first. Then, novel converter topologies with the higher power density and cost‐efficiency are presented, including the hybrid modular multilevel converter (MMC), alternative arm converter (AAC), and diode rectifier (DR). Next, several OWF HVDC transmission system topologies are introduced, including terminal‐hybrid, station‐hybrid and all‐DC delivered system. Furthermore, the key technologies for OWF HVDC operation and control are summarized, including grid‐forming control strategy for offshore wind turbines, stability analysis method, corresponding stability enhancement measures and frequency support control strategies. Additionally, the fault ride‐through and protection strategies for different fault locations have been presented. Finally, the main conclusions and prospects for OWF HVDC are summarized.

26 November 2025 in Electronics
Verified
Journal Article
Open access
PDF file
JDJunpeng Deng
Junpeng Deng
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
JDJinglei Deng
Jinglei Deng
SLShuai Liang
Shuai Liang
RYRongxiang Yuan
Rongxiang Yuan
Xuefeng GeXuefeng Ge
Xuefeng Ge
Existing studies on commutation failure during fault recovery (CFFR) in line-commutated converter high-voltage direct current (LCC-HVDC) systems often neglect the critical influence of phase-locked loop phase tracking error (PLL-PTE) and fail to provide effective control strategies to address this issue. This paper investigates the influence of PLL-PTE on CFFR through electromagnetic transient simulations based on a modified CIGRE benchmark model. The study reveals that phase angle jump (PAJ) caused by DC power fluctuations (DPF) and AC network reconfigurations (ANR) is the fundamental source of PLL-PTE, which in turn leads to the occurrence of CFFR. To mitigate this, a novel control strategy is proposed that dynamically adjusts the extinction angle based on historical and predicted PAJ data. Simulation results demonstrate that the proposed method effectively suppresses CFFR under various fault conditions, including different fault types, locations, resistances, and initiation times. Compared with existing control schemes, the proposed approach avoids adverse side effects while exhibiting strong robustness and adaptability. The proposed control strategy significantly enhances the stability and reliability of LCC-HVDC systems, offering great potential for practical application in increasingly complex power grid environments.

1 January 2026 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Open access
JDJunpeng Deng
Junpeng Deng
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
FCFan Cheng
Fan Cheng
BMBeilin Mao
Beilin Mao
ZWZhang Wen
Zhang Wen
WWWei Wang
Wei Wang
The sending-end hybrid cascaded (SE-HC) HVDC system formed by a DC-side series connection of a line-commutated-converter (LCC) and a modular-multilevel-converter (MMC) has become a crucial solution for large-scale renewable energy long-distance transmission due to its advantages of large transmission capacity, high operation flexibility, and strong grid support capability compared with conventional LCC-HVDC systems. However, SE-HC MMC may face DC overvoltage under sending-end (SE) AC system faults, which is caused by the HVDC system's active power surplus. To address this issue, this paper first analyzes the mechanisms and influencing factors of DC overvoltage based on the power balance model. Then, an overvoltage suppression strategy is proposed by coordinating the transmitted active power from SE and receiving-end (RE) converters, renewable energy bases (REBs), and energy dissipation devices. This method does not rely solely on the energy dissipation device to absorb surplus active power. Instead, by fully leveraging the control flexibility of the SE MMC, it enables the RE MMCs and REBs to detect SE AC system faults, thereby increasing active power transmission and reducing surplus active power during the fault. As a result, more effective suppression of DC overvoltage is achieved, and the required capacity of the energy dissipation device in the system is reduced. A monopolar model of the SE-HC HVDC system has been established in PSCAD/EMTDC, and the feasibility and superiority of the proposed control strategy have been verified through this model.

12 May 2023
Verified
Conference Paper
Closed access
JDJunpeng Deng
Junpeng Deng
Liangzhong YaoLiangzhong Yao
Liangzhong Yao
FCFan Cheng
Fan Cheng
RCRuisi Chen
Ruisi Chen
XLXianyu Li
Xianyu Li
For the offshore wind power using multilevel modular converter (MMC) based high voltage direct current (HVDC) system, in the case of sending-end asymmetric faults, the offshore MMC generally uses auxiliary positive sequence voltage correction control to prevent overvoltage in the healthy phase. However, due to over-adjustment of the MMC AC voltage reference value, this control can lead to significant reduction in the HVDC system active power transmission capacity when the voltage drop depth is large. Therefore, this paper proposes an enhanced MMC voltage correction control based on nonlinear droop control, adopting the per unit value of the MMC valve-side voltage positive sequence component as the droop coefficient to alleviate the over-adjustment problem in the AC voltage during the fault period. So that the adverse effects of HVDC active power transmission drop on onshore AC grid can be mitigated. The feasibility and superiority of the proposed method were verified through ${\mathbf{PSCAD}}/{\mathbf{EMTDC}}$ simulation cases, which can achieve overvoltage suppression and fault-ride through (FRT).