Akanksha Singh

Dr. Akanksha Singh


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2019 in IEEE Power and Energy Technology Systems Journal
Verified
Journal Article
Open access
ASAkanksha Singh
Akanksha Singh
BMBehrooz Mirafzal
Behrooz Mirafzal
The proposed three-phase boost Current Source Inverter (CSI) is equipped with Reverse-Blocking IGBTs (RB-IGBT) and the Phasor Pulse Width Modulation (PPWM) switching pattern to provide system efficiency greater than 92% and high boost ratios (VLL/Vdc) up to 3.5 in a single stage. The boost CSI results in elimination of dc-dc boost converter or a step-up transformer needed in dc-ac converters operating with a dc input voltage lower than the output line-to-line voltage. In this paper, the relationship between the fundamental component of the inverter output current and the PPWM modulation index is derived and then confirmed by simulation and experimentally obtained data in both stand-alone and grid-tied modes of operation. In this work, a 2kW,208VLLrms,60-120Vdc RB-IGBT-based boost CSI is prototyped to explore capabilities of the grid-tied boost CSI in terms of efficiency and THD for various input dc voltage and output power levels.

8 December 2017 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ASAkanksha Singh
Akanksha Singh
JBJoseph Benzaquen
Joseph Benzaquen
BMBehrooz Mirafzal
Behrooz Mirafzal
Permanent Magnet Synchronous Generator (PMG) based Direct-DriveWind Turbines (DDWTs) have recently drawn the attention of the wind power market given their low operation and maintenance cost, reliability, and longer lifetime. In this paper, a zero dc-link impedance topology for DDWT-PMG systems is presented. The proposed topology eliminates the use of the failure prone dc-bus capacitor by replacing the grid-side converter with a Phasor Pulse Width Modulation (PPWM) boost Current Source Inverter (CSI). Furthermore, the novelty of the proposed topology lies in utilizing the PMG synchronous inductance as the dc-link inductor required by the boost-CSI, thus decreasing the overall system weight and size. In addition, the PPWM boost-CSI enables a high voltage-boosting ratio, which allows the design of a low-voltage PMG. As a result, the PMG size, weight, and high-cost PM material volume can be decreased. The feasibility of the low-voltage generator is investigated through Finite Element (FE) computations using as a base for comparison an existing 1.5MW DDWT-PMG. This comparison demonstrates the reduction in the generator volume, PM material, and in the total weight of the generator. Finally, the proposed topology is validated through simulations and experiments.

17 August 2021
Verified
Report
Closed access
PDF file
KPKumaraguru Prabakar
Kumaraguru Prabakar
ASAkanksha Singh
Akanksha Singh
MRMatthew Reynolds
Matthew Reynolds
MLMonte Lunacek
Monte Lunacek
LMLucas Monzon
Lucas Monzon
DVDeepthi Vaidhynathan
Deepthi Vaidhynathan
Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

1 September 2018
Verified
Conference Paper
Open access
ASAkanksha Singh
Akanksha Singh
MCMadhu Chinthavali
Madhu Chinthavali
SSScott Sudhoff
Scott Sudhoff
KBKevin Bennion
Kevin Bennion
KPKumaraguru Prabakar
Kumaraguru Prabakar
SCSteven Campbell
Steven Campbell
The future power grid will involve increasing numbers of power converters while growing the complexity of the power systems. The future of the power converters is driven by developments in the wide-bandgap semiconductor devices. In this paper, a 50-kW string photovoltaic (PV) inverter designed and developed using all silicon carbide (SiC) semiconductor devices is presented. The inverter design includes an additively manufactured power block, symmetrical Y-core inductors for the ac-side filter, and advanced inverter controls for grid support functionality. This inverter uses the conventional three-phase voltage source inverter topology and optimizes the design for SiC-based devices. The paper includes details on power module design, heatsink optimization, symmetrical Y-core filter inductor design, inverter thermal design, and further experimental validation of the inverter performance. In addition to presenting the quantification of inverter efficiency and quality of the output, the paper presents the validation of advanced grid-support functions required by the IEEE 1547 standards for the interconnection of distributed energy resources.

14 March 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
XFXuhui Feng
Xuhui Feng
RKRamchandra Kotecha
Ramchandra Kotecha
SNSreekant Narumanchi
Sreekant Narumanchi
ASAkanksha Singh
Akanksha Singh
BMBarry Mather
Barry Mather
JWJin Wang
Jin Wang
As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

4 August 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XZXiangqi Zhu
Xiangqi Zhu
ASAkanksha Singh
Akanksha Singh
BMBarry Mather
Barry Mather
This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. The analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.