Galman Iwona

Dr. Galman Iwona

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
JKJan Kubica
Jan Kubica
GIGalman Iwona
Galman Iwona
The article presents laboratory tests on the impact of the mixing water content used in the preparation of fresh mortar on the flexural and compressive strength of one of the dry-mix mortars produced by a leading European producer and dedicated to bricklaying with clinker elements. The development of these parameters in relation to curing time was also analyzed. The mortar samples were prepared from a factory-made mortar mix using 4.0 L (the value recommended by the mortar manufacturer), 4.5 L, and 5 L of water per 25 kg bag of ready-made, pre-mixed dry mortar mix. All samples were tested in five series after 5, 9, 14, 21, and 28 days of sample curing. The results of these tests showed that the use of 6 and 18% more mixing water than recommended by the manufacturer (4.5 and 5 L per bag) adversely affected the basic mechanical parameters of the tested mortar. Moreover, it was found that the highest compressive strength values were obtained after 21 days of curing and not after 28 days as usual. It was also found that hardening time and higher than recommended water content adversely affected the bending strength of the mortar.


22 February 2024 in Materials
Verified
Journal Article
Open access
PDF file
AZArmando Zagaroli
Armando Zagaroli
JKJan Kubica
Jan Kubica
GIGalman Iwona
Galman Iwona
KFKristian Falkjar
Kristian Falkjar
It is believed that the use of mortars based on air lime in the construction and renovation of brick buildings has a number of advantages, especially those closely related to the durability and strength of the structure. However, there is still a noticeable difference in the mechanical properties of these materials. This research investigated the mechanical characteristics of a mixed cement–lime mortar with the two most popular proportions of an air lime, cement, and sand mix: 1:1:6 and 1:2:9 (by volume). Mechanical tests were performed on standard and non-standard samples to assess compressive strength, tensile strength, flexural strength, and fracture energy. The obtained results indicate the possibility of using these mixtures in modern masonry construction, as well as in the aspect of sustainable development. Additionally, lime mortar with a higher lime content can be used in non-load-bearing walls and in renovation and repair works.

2 April 2020 in Buildings
Verified
Journal Article
Open access
PDF file
Radosław JasińskiRadosław Jasiński
Radosław Jasiński
GIGalman Iwona
Galman Iwona
Joints between walls are very important for structural analysis of each masonry building at the global and local level. This issue has often been neglected in the case of traditional joints and relatively squat walls. At present, the issue of wall joints is becoming particularly important due to the continuous drive for simplifying structures, introducing new technologies and materials. Eurocode 6 and other standards (American, Canadian, Chinese, and Japanese) recommend inspecting joints between walls, but no detailed procedures have been specified. This paper presents our own tests on joints between walls made of autoclaved aerated concrete (AAC) masonry units. Tests included reference models composed of two wall panels joined perpendicularly with a standard masonry bond (six models), with classic steel and modified connectors (twelve models). The shape and size of test models and the structure of a test stand were determined on the basis of the analysis of the current knowledge, pilot studies and numerical FEM (Finite Element Method) - based analyses. The analyses referred to the morphology and failure mechanism of models. Load-displacement relationships for different types of joints were compared and obtained results were related to results for reference models. The mechanisms of cracking and failure was found to vary, and clear differences in the behaviour and load capacity of each type of joint were observed. The individual working phases of joints were determined and defined, and an empirical approach was proposed for the determination of forces and displacement of wall joints.

11 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
Marcin KozłowskiMarcin Kozłowski
Marcin Kozłowski
GIGalman Iwona
Galman Iwona
Radosław JasińskiRadosław Jasiński
Radosław Jasiński
This paper presents the development of a numerical model aimed at the simulation of nonlinear behaviour of traditional joints between walls made of autoclaved aerated concrete (AAC) masonry units. Nonlinear behaviour and cracking of AAC and mortar were simulated using the concrete damaged plasticity (CDP) model available in the ABAQUS finite element software. The paper also presents and discusses the results of an experimental campaign involving testing six T-shaped, monosymmetric samples with traditional joints between walls loaded in shear. The results were used to validate the numerical model. The validation confirmed that the model is capable of producing accurate results and predicting the structural behaviour with a reasonably good accuracy in elastic and post-elastic stages. Furthermore, a sensitivity study was conducted, in which the variation of elastic modulus, Poisson’s ratio, tensile strength, compression strength and fracture energy of AAC was investigated. Results showed that the variation of elastic modulus, tensile strength and fracture energy is most critical to the structural behaviour of the model, while variation of the remaining parameters has a negligible effect on the results.

1 September 2014 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
Marta KałużaMarta Kałuża
Marta Kałuża
GIGalman Iwona
Galman Iwona
JKJan Kubica
Jan Kubica
CAChiara Agneloni
Chiara Agneloni
In recent years, the autoclaved aerated concrete has become as one of the most popular material used in erecting of small housings as well as multi-apartment residential buildings. Recommended construction technology involves the use of the ACC blocks arranged on thin bed joints, with the head joints left unfilled. Practice has shown that this type of construction is characterised by low crack resistance, which was also confirmed during experimental investigation [1]. One of the solutions to this problem, proposed by the staff of the Silesian University of Technology, was the superficial strengthening of such type of masonry walls. Strengthening materials tested so far (glass and carbon fibre mesh used in FRP system solutions) gave very promising results but a relatively high cost of the material itself constituted the main drawback. This prompted a further search for new and relatively inexpensive materials that would allow improving the use of the existing structures made of AAC blocks. The goal of the laboratory test results presented in this paper was to determine the influence of wall surface strengthening made of not expensive GRFP mesh (dedicated as reinforcement of thin external plastering in thermal insulation systems) on the behaviour and mechanical properties of masonry wallettes made of AAC blocks with thin joints. Three series of masonry specimens were tested: not strengthened wallettes (as reference members), walls with superficial strengthening only on one side and walls with both sides strengthened. A total of 18 specimens subjected to diagonally compressive loading were tested (6 in each series). The results turned out to be highly promising. Increasing of shear capacity of both types of superficially strengthened masonry in comparison with reference members was observed. The tests also allowed determining a positive effect of external reinforcement on the type of cracking and failure mode of such walls.