Luis A Bujedo

Dr. Luis A Bujedo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPedro Martínez
Pedro Martínez
PMPedro Martínez
Pedro Martínez
VFVíctor Manuel Soto Francés
Víctor Manuel Soto Francés
LBLuis A Bujedo
Luis A Bujedo
JRJuan Rodriguez
Juan Rodriguez
Solar cooling systems have the advantage of the coincidence between the hours of cooling demand and the hours of solar radiation availability, and they can contribute to reduce the energy consumption in buildings. However, the high cost of thermal solar cooling facilities with absorption chillers, maintenance issues, legionella risk and water consumption (associated to the necessary cooling tower) have limited the use of these systems to demonstration projects. A simplified Transient System Simulation Tool (TRNSYS) model was developed to provide the owner of the demonstration facility the information he needs for design decision-making. This model was validated with experimental data registered in a solar cooling system designed and built by the authors. Different collector field surfaces, hot water storage tank volumes, and absorption machine driving temperatures were analyzed for a hotel demonstration facility. In terms of the energy delivered to the absorption chiller the optimum dimensioning corresponded to the lowest values of the driving temperature (75 °C) and specific storage volume (15 Lm2). From an economic point of view, the saving of 1515 euros per year when compared with an electric compression chiller does not compensate the investment of 3000 euros per kW of cooling capacity that cost the thermal solar cooling facility.

17 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MCManuel Andrés Chicote
Manuel Andrés Chicote
FRFilipe Rebelo
Filipe Rebelo
ÁCÁlvaro Corredera
Álvaro Corredera
António FigueiredoAntónio Figueiredo
António Figueiredo
José L. HernándezJosé L. Hernández
José L. Hernández
JSJesús Samaniego
Jesús Samaniego
Lightweight construction is experiencing a significant market implementation with sustained growth both for new buildings and retrofitting purposes. Despite the acknowledged advantages of this type of construction, their reduced thermal inertia can jeopardize indoor thermal comfort levels while leading to higher energy consumption due to high indoor temperature fluctuations and overheating rates. The incorporation of phase change materials (PCMs) into constructive solutions for lightweight buildings is a promising strategy to guarantee adequate thermal comfort conditions. Particularly, the utilization of mortars embedding PCMs as an indoor wall coating for new and existing buildings represents a solution that has not been widely explored in the past and needs further development and validation efforts. This work pursues the analysis of the thermal regulation effects generated by two thermally-enhanced mortars incorporating microencapsulated PCMs with different operating temperature ranges. To that end, an experimental campaign was conducted in Valladolid (Spain) to address the investigation of the proposed solution under a real-scale relevant environment. The proposed mortars were applied as an indoor coating to the envelope of a single-zone lightweight construction that was monitored (under different weather conditions along 1-year monitoring campaign) together with an identical building unit where the mortar was not added to the constructive base layer. The analysis of indoor temperature fluctuations under free-floating operating mode as well as the energy consumption of HVAC equipment under controlled-temperature operation was specifically targeted. Results derived from the continuous monitoring campaign revealed lower temperature fluctuations during summer and shoulder seasons, reducing indoor temperature peaks by 1–2 °C, and producing a time delay of 1–1.5 h into the temperature wave. A clear reduction in energy use due to the incorporation of the PCM-based indoor coating panels is also observed. Thus, this experimental research contributes to proving that the use of innovative mortars incorporating embedded PCMs enables the development of high-end efficient building solutions with innovative materials towards a sustainable built environment.

18 July 2024 in Avances en Ciencias y Técnicas del Frío - 12. Actas del XII Congreso Ibérico y X Congreso Iberoamericano de Ciencias y Técnicas del Frío CYTEF 2024
Verified
Journal Article
Open access
PDF file
LBLuis A Bujedo
Luis A Bujedo
MCManuel Andrés Chicote
Manuel Andrés Chicote
JMJuan Jesús Samaniego Muñoz
Juan Jesús Samaniego Muñoz
ABAlberto Belda-González
Alberto Belda-González
Ismael Lozano-GabarreIsmael Lozano-Gabarre
Ismael Lozano-Gabarre
Los sistemas de bomba de calor (BC) agua-agua está aumentado debido a la extensión de los sistemas de redes de calor de distrito y a la cada vez mayor necesidad de penetración de sistemas renovables en la generación térmica, aprovechando sistemas geotérmicos para la climatización residencial facilitando la evolución hacia nuevos escenarios de participación e implicación en el mercado energético. El presente trabajo muestra los resultados obtenidos de la implementación y calibración de un modelo de estimación del COP de una BC empleando para ello datos obtenidos del ensayo de la misma en el banco de ensayos del que dispone CARTIF. El modelo parte del método de estimación generalizado presentado por Jensen, cuyos parámetros dependientes de las características constructivas de la máquina y del refrigerante empleado se ajustan usando datos experimentales de la BC operando en diversas condiciones de temperatura de sus focos de intercambio energético. Para realizar este proceso de ajuste, se realiza una optimización del valor de los parámetros para tratar de minimizar la media del error relativo de todos los ensayos obtenido. Tras el proceso de calibración, se obtiene una estimación del COP basada en las condiciones de operación que presenta un error medio menor al 10%.