Active suspension control strategies are a top priority in active suspension system. The current research on active suspension control strategies is mostly focused on two-axle vehicles, and there is less research investigating multi-axle vehicles. Additionally, their effective implementation is dependent on accurate mathematical models, and most of them adopt force feedback control, which is vulnerable to external interference. To solve these problems, this paper proposes an active suspension control strategy based on Inertial Measurement Unit. The multi-axle emergency rescue vehicle is made to be equivalent to a 3-degrees-of-freedom parallel mechanism by using the method of grouping and interconnecting the suspension units of the whole vehicle. The attitude change of the vehicle body was transformed into the servo actuator’s displacement by solving the inverse solution of the parallel mechanism position and the action of the servo actuator was driven in reverse according to the displacement obtained. In this way, the vehicle body attitude can be compensated, and the ride comfort and the handling stability of the vehicle can be improved. To verify the effectiveness of the control strategy proposed, the three-axle six vehicle was taken as the research object, the position inverse solution of its equivalent 3-degrees-of-freedom parallel mechanism was deduced, and a high-pass filter was designed. The three-axle vehicle experiment platform integrating active suspension and hydro-pneumatic suspension was built, and the gravel road and slope road experiments were carried out and the results compared with those obtained with hydro-pneumatic suspension. The experiment results showed that, compared with hydro-pneumatic suspension, the active suspension control strategy based on Inertial Measurement Unit proposed in this paper can not only stabilize the body attitude, but also effectively suppress body vibration, improving the ride comfort and handling stability of the vehicle significantly.
The displacement tracking performance of the electro-hydraulic servo actuator is critical for hydraulic active suspension control. To tackle the problem of slow time-varying parameters in the existing actuator dynamics model, a nonlinear adaptive back-stepping control (ABC) approach is adopted. Simultaneously, the parameters of the nonlinear ABC are difficult to configure, resulting in a poor control effect. An enhanced particle swarm optimization (PSO) approach integrating crazy particles (CP) and time-varying acceleration coefficients (TVAC) is suggested to optimize the controller settings. Furthermore, in order to obtain satisfactory dynamic characteristics of the transition process, the absolute value of the error time integral performance index is used as the minimum performance index function of parameter selection, and the square term of the control input is added to the performance index function to prevent excessive controller energy. Finally, it can be observed from the simulation results of the highest value of the displacement tracking error, the average value of error, and the standard deviation of error that the performance of the ABC parameters optimized by PSO+CP+ATVC is superior to the manually given ABC parameters. Therefore, this control method significantly improves the stability and speed of the control system. It provides a new research idea for the parameter optimization of controllers.
As piezoelectric pumps are used in more fields, they are gradually failing to meet the application requirements due to their low output performance. Therefore, improving the output performance of piezoelectric pumps helps to expand their applications. This paper argued that the dynamic load of liquid in the inlet and outlet pipelines was an important factor that weakened the performance of piezoelectric pumps. Therefore, in order to reduce the dynamic load, it was proposed to replace the conventional piezoelectric pump inlet and outlet by an elastic inlet and outlet. After introducing the structure and working principle of elastic inlet and outlet, the mechanism of reducing the dynamic load by elastic inlet and outlet was analyzed. Then, the influence of the elastic cavity height on the performance of the piezoelectric pump was studied from both fluid simulation and theoretical analysis. Finally, several prototypes were made. The effectiveness of the elastic inlet and outlet on improving the performance of the prototype and the effect of the elastic cavity height on the performance of the prototype were tested, respectively. The test results showed that the elastic inlet and outlet effectively improved the flow rate and output backpressure without increasing the maximum output backpressure. The maximum flow rate of the pump system without load was increased by 36%. In addition, the elastic cavity height adversely affected the flow rate and output backpressure of the prototypes, but had no effect on the maximum output backpressure. In summary, the elastic inlet and outlet can effectively increase the output performance of the piezoelectric pump, but the design height should be appropriately reduced.
The paper is a continuation of our work on the dynamic load in piezoelectric pumps. In the study, the dynamic load of liquid in the pipelines was proposed as a key factor that limits the output performance of piezoelectric pumps. To decrease the dynamic load, a piezoelectric pump with two elastic chambers was proposed in our previous published work. In this paper, the performance and key parameters of the piezoelectric pump with two elastic chambers were studied through theoretical analyses and experimental tests. After establishing the mathematical model of the piezoelectric pump with two elastic chambers, the paper theoretically analyzed the performance of the pump and the effect of different structural parameters on the performance. Then prototypes with a range of structural parameters were developed and tested. As revealed from the test results, the elastic chamber effectively decreased the dynamic load of the liquid in the pipelines and the flow rate of the prototype with two elastic chambers was higher than that of the prototype with one or no elastic chamber. However, the elastic chamber did not lead to the increase in the maximum output backpressure of the prototype. Adopting an elastic diaphragm exhibiting a smaller stiffness or a larger diameter could help decrease the dynamic load of the liquid. The elastic chamber more significantly impacted the flow rate of the piezoelectric pump with long pipelines. The pump chamber height had a significant effect on the output performance of the piezoelectric pump with two elastic chambers, which is consistent with the conventional piezoelectric pump. At the height of 0.2 mm, the flow rate of the prototype with two elastic chambers was peaked at 7.7 mL/min; at the height of 0.05 mm, the output backpressure reached the highest of 28.2 kPa. The dynamic load could decrease the amplitude of the piezoelectric vibrator, whereas the prototype with two elastic chambers could effectively reduce the impact of dynamic load on the piezoelectric vibrator. The flow rate decreased almost linearly with the backpressure. Under the same backpressure, the flow rate of the prototype with two elastic chambers was higher than that of the prototype without elastic chamber, and the flow rate difference between the two prototypes gradually decreased with the backpressure.