Tomas Hlozek

Dr. Tomas Hlozek


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in European Neuropsychopharmacology
Verified
Journal Article
Closed access
THTomas Hlozek
Tomas Hlozek
LULibor Uttl
Libor Uttl
LKLukáš Kadeřábek
Lukáš Kadeřábek
MBMarie Balíková
Marie Balíková
ELEva Lhotková
Eva Lhotková
TPTomáš Páleníček
Tomáš Páleníček

1 August 2018 in Journal of Cleaner Production
Verified
Journal Article
Closed access
TKTomáš Křížek
Tomáš Křížek
MBMiroslava Bursová
Miroslava Bursová
RHRachel Horsley
Rachel Horsley
MKMartin Kuchař
Martin Kuchař
PTPetr Tuma
Petr Tuma
THTomas Hlozek
Tomas Hlozek

1 August 2019 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
ANAlžběta Nemeškalová
Alžběta Nemeškalová
MBMiroslava Bursová
Miroslava Bursová
DSDavid Sykora
David Sykora
MKMartin Kuchar
Martin Kuchar
RČRadomír Čabala
Radomír Čabala
THTomas Hlozek
Tomas Hlozek

14 July 2015 in Journal of Analytical Toxicology
Verified
Journal Article
Open access
PDF file
MBMiroslava Bursová
Miroslava Bursová
THTomas Hlozek
Tomas Hlozek
RCRadomir Cabala
Radomir Cabala
A simple, cost-effective headspace gas chromatography (GC) method coupled with GC with flame ionization detection for simultaneous determination of methanol, ethanol and formic acid was developed and validated for clinical and toxicological purposes. Formic acid was derivatized with an excess of isopropanol under acidic conditions to its volatile isopropyl ester while methanol and ethanol remained unchanged. The entire sample preparation procedure is complete within 6 min. The design of the experiment (the face-centered central composite design) was used for finding the optimal conditions for derivatization, headspace sampling and chromatographic separation. The calibration dependences of the method were quadratic in the range from 50 to 5,000 mg/L, with adequate accuracy (89.0–114.4%) and precision (<12%) in the serum. The new method was successfully used for determination of selected analytes in serum samples of intoxicated patients from among those affected by massive methanol poisonings in the Czech Republic in 2012.

1 October 2017 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
THTomas Hlozek
Tomas Hlozek
TKTomáš Křížek
Tomáš Křížek
PTPetr Tuma
Petr Tuma
MBMiroslava Bursová
Miroslava Bursová
PCPavel Coufal
Pavel Coufal
RCRadomir Cabala
Radomir Cabala

2 February 2017 in Journal of Analytical Toxicology
Verified
Journal Article
Open access
PDF file
MZMonika Zidkova
Monika Zidkova
THTomas Hlozek
Tomas Hlozek
MBMartin Balik
Martin Balik
OKOndrej Kopecky
Ondrej Kopecky
PTPavel Tesinsky
Pavel Tesinsky
MBMarie Anna Balikova
Marie Anna Balikova
3-Methoxy-phencyclidine (3-MeO-PCP) is a structural derivative of the dissociative hallucinogen phencyclidine (PCP). Although PCP toxicity is well documented, little is known about this new psychoactive substance despite being available on the black market even in central Europe. The objective of this case report is to present clinical and laboratory data of analytically confirmed non-fatal intoxication of two subjects with 3-MeO-PCP. A preliminary assessment of potential metabolites excreted into urine was enabled using the liquid chromatography high resolution mass spectrometric method.