Radomir Cabala

Dr. Radomir Cabala

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1997 in Journal of the Chemical Society, Faraday Transactions
Verified
Journal Article
Closed access
PDF file
RCRadomir Cabala
Radomir Cabala
VMVeit Meister
Veit Meister
KPKarin Potje-Kamloth
Karin Potje-Kamloth
The sensing properties of a conducting polymer, polypyrrole (PP), are modified by competitive doping with tetrafluoroborate or perchlorate and tetrasulfonated metallophthalocyanines (MPcTS, M=Ni or Cu). The Kelvin probe responses of these polymers to dimethylmethylphosphonate, tetrachloroethene and NO x are compared with Kelvin probe signals of commonly prepared polypyrrole, doped with only one anion such as tetrafluoroborate, perchlorate, toluene-p-sulfonate, NiPcTS and CuPcTS. Improved sensing properties were achieved due to competitive doping with the above mentioned anions, compared to commonly prepared PP. The detection range for NO x is 0.4–40 ppm in ambient air and 2–40 ppm in ambient air for dimethylmethylphosphonate. The sensitivity to both substances lies in the range of 67–83 mV (ppm decade) -1 .

1 December 2009 in Journal of Chromatography A
Verified
Journal Article
Closed access
VDVeronika Dufková
Veronika Dufková
RCRadomir Cabala
Radomir Cabala
DMDoubravka Maradová
Doubravka Maradová
Martin ŠtíchaMartin Štícha
Martin Štícha

7 July 2005 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
MEM. H. A. El-Zohri
M. H. A. El-Zohri
RCRadomir Cabala
Radomir Cabala
HFH. Frank
H. Frank

1 January 2011 in Food Chemistry
Verified
Journal Article
Closed access
IOIvan Ostrovský
Ivan Ostrovský
RCRadomir Cabala
Radomir Cabala
RKRóbert Kubinec
Róbert Kubinec
RGRenáta Górová
Renáta Górová
JBJaroslav Blaško
Jaroslav Blaško
WLWilhelm Lorenz
Wilhelm Lorenz

1 April 2012 in Chemosphere
Verified
Journal Article
Closed access
VDVeronika Dufková
Veronika Dufková
RCRadomir Cabala
Radomir Cabala
VŠVáclav Ševčík
Václav Ševčík

14 July 2015 in Journal of Analytical Toxicology
Verified
Journal Article
Open access
PDF file
MBMiroslava Bursová
Miroslava Bursová
THTomas Hlozek
Tomas Hlozek
RCRadomir Cabala
Radomir Cabala
A simple, cost-effective headspace gas chromatography (GC) method coupled with GC with flame ionization detection for simultaneous determination of methanol, ethanol and formic acid was developed and validated for clinical and toxicological purposes. Formic acid was derivatized with an excess of isopropanol under acidic conditions to its volatile isopropyl ester while methanol and ethanol remained unchanged. The entire sample preparation procedure is complete within 6 min. The design of the experiment (the face-centered central composite design) was used for finding the optimal conditions for derivatization, headspace sampling and chromatographic separation. The calibration dependences of the method were quadratic in the range from 50 to 5,000 mg/L, with adequate accuracy (89.0–114.4%) and precision (<12%) in the serum. The new method was successfully used for determination of selected analytes in serum samples of intoxicated patients from among those affected by massive methanol poisonings in the Czech Republic in 2012.