24 September 2021 in Building and Environment
Verified
Journal Article
Open access
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
MKMartin Kiil
Martin Kiil
PWPawel Wargocki
Pawel Wargocki
ABAtze Boerstra
Atze Boerstra
OSOlli Seppänen
Olli Seppänen
LMLidia Morawska
Lidia Morawska
A new design method is proposed to calculate outdoor air ventilation rates to control respiratory infection risk in indoor spaces. We propose to use this method in future ventilation standards to complement existing ventilation criteria based on the perceived air quality and pollutant removal. The proposed method makes it possible to calculate the required ventilation rate at a given probability of infection and quanta emission rate. Present work used quanta emission rates for SARS-CoV-2 and consequently the method can be applied for other respiratory viruses with available quanta data. The method was applied to case studies representing typical rooms in public buildings. To reduce the probability of infection, the total airflow rate per infectious person revealed to be the most important parameter to reduce the infection risk. Category I ventilation rate prescribed in the EN 16798-1 standard satisfied many but not all type of spaces examined. The required ventilation rates started from about 80 L/s per room. Large variations between the results for the selected case studies made it impossible to provide a simple rule for estimating the required ventilation rates. Consequently, we conclude that to design rooms with a low infection risk the newly developed ventilation design method must be used.

23 October 2024 in Building and Environment
Verified
Journal Article
Open access
MKMartin Kiil
Martin Kiil
AMAlo Mikola
Alo Mikola
KVKarl-Villem Võsa
Karl-Villem Võsa
Raimo SimsonRaimo Simson
Raimo Simson
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski

23 January 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
MKMartin Kiil
Martin Kiil
Raimo SimsonRaimo Simson
Raimo Simson
MTMartin Thalfeldt
Martin Thalfeldt
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
Local thermal comfort and draught rate has been studied widely. There has been more meaningful research performed in controlled boundary condition situations than in actual work environments involving occupants. Thermal comfort conditions in office buildings in Estonia have been barely investigated in the past. In this paper, the results of thermal comfort and draught rate assessment in five office buildings in Tallinn are presented and discussed. Studied office landscapes vary in heating, ventilation and cooling system parameters, room units, and elements. All sample buildings were less than six years old, equipped with dedicated outdoor air ventilation system and room conditioning units. The on-site measurements consisted of thermal comfort and draught rate assessment with indoor climate questionnaire. The purpose of the survey is to assess the correspondence between heating, ventilation and cooling system design, and the actual situation. Results show, whether and in what extent the standard-based criteria for thermal comfort is suitable for actual usage of the occupants. Preferring one room conditioning unit type or system may not guarantee better thermal environment without draught. Although some heating, ventilation and cooling systems observed in this study should create the prerequisites for ensuring more comfort, results show that this is not the case for all buildings in this study.

30 June 2020 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Raimo SimsonRaimo Simson
Raimo Simson
TRTaaniel Rebane
Taaniel Rebane
MKMartin Kiil
Martin Kiil
MTMartin Thalfeldt
Martin Thalfeldt
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
In this study we analysed the climatic conditions for infiltration estimation, different calculation methods and infiltration impact on heat load for heating systems dimensioning. To determine the wind conditions at low air temperatures of the coastal- and inland climatic zones in Estonia, 42 years of climatic data for Tallinn and Tartu were investigated. Calculation models with detailed air leakages were constructed of a single and two-storey detached house using dynamic simulation software IDA ICE. Simulations were carried out with the constructed calculation models, simulating various wind and sheltering conditions to determine the heating load of the buildings under measured wind conditions at the design external air temperatures. The simulation results were compared with results calculated with European Standard EN 12831:2017, methodology given in the Estonian regulation for calculating energy performance of buildings and with simulations using the default settings in IDA ICE based on the ASHRAE design day conditions. The percentage of heat losses caused by infiltration was found as 13-16% of all heat losses for the studied buildings. Simulations with historical climate periods showed that even in windy weather conditions the heating system dimensioned by the methods analysed may not be able to provide the required indoor air temperature. Analysis using the coldest and windiest periods showed that when systems are dimensioned by the studied methods, the highest decline in indoor air temperature occurs on the windiest day and not on the coldest day. The impact of high wind speeds and low sheltering conditions resulted up to 50% of all heat losses.

1 October 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
MKMartin Kiil
Martin Kiil
Raimo SimsonRaimo Simson
Raimo Simson
Francesco De LucaFrancesco De Luca
Francesco De Luca
MTM Thalfeldt
M Thalfeldt
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
Learning performance is strongly related to thermal comfort and lighting conditions of classrooms. Poor facade design can result in high indoor temperatures or insufficient access to natural light. To maintain the required temperatures and illuminance levels in such rooms may require intensive use of artificial lighting and active cooling systems, which are energy-intensive, costly to install, operate and maintain. The purpose of this study was to determine essential parameters and facade design options that ensure overheating prevention and fulfil daylight requirements in classrooms without mechanical cooling. The present study is based on simulations of a parametric room model with variable dimensions and orientations. Facade glazing solutions with optimal combination of solar factor and visible light transmittance were used to minimize overheating risk and maximize natural lighting impact. For east, south and west oriented facades, the effect of horizontal shading was also analysed. Overheating assessment through indoor temperature simulations was conducted with dynamic simulation software IDA ICE, daylighting was simulated with DIVA4 coupled with Grasshopper software. Results show that classrooms without mechanical cooling require in depth analysis to determine satisfying solutions for both overheating and daylighting criteria. The results of this paper can be used for early stage facade design guide for school buildings or similar use free-running buildings.

30 June 2020 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
MKMartin Kiil
Martin Kiil
MKMartin-Sven Käärid
Martin-Sven Käärid
PKPaul Klõšeiko
Paul Klõšeiko
KVKarl-Villem Võsa
Karl-Villem Võsa
RSRaimo Simson
Raimo Simson
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
This study analyses the effect of air circulation around diagonal tie connectors in precast sandwich panels on heating energy demand, energy performance value and heating costs of a sample residential building. Dynamic simulations were performed using 4 different climatic boundary conditions: Estonian test reference year, Estonian 48-year weather dataset as well as data from Eastern Germany and Northern Finland. The results show that the effect of the thermal bridge is most noticeable in total room heating energy demand (increase of 10.3%), while the influence on energy performance value was 1.1%. The relative increase of total room heating energy demand was similar (7.0-10.3%) in all studied climatic regions.