Single room ventilation units with heat recovery is one of the ventilation solutions that have been used in renovated residential buildings in Estonia. In multi-story buildings, especially in a cold climate, the performance of units is affected by the stack effect and wind-induced pressure differences between the indoor and the outdoor air. Renovation of the building envelope improves air tightness and the impact of the pressure conditions is amplified. The aim of this study was to predict the air pressure conditions in typical renovated multi-story apartment buildings and to analyze the performance of room-based ventilation units. The field measurements of air pressure differences in a renovated 5-story apartment building during the winter season were conducted and the results were used to simulate whole-year pressure conditions with IDA-ICE software. Performance of two types of single room ventilation units were measured in the laboratory and their suitability as ventilation renovation solutions was assessed with simulations. The results show that one unit stopped its operation as a heat recovery ventilator. In order to ensure satisfactory indoor climate and heat recovery using wall mounted units the pressure difference values were determined and proposed for correct design.
11 June 2018 in Management of Environmental Quality: An International Journal
Purpose: Electric lighting accounts for a large share of energy consumption in commercial buildings. Utilization of daylight can significantly help to reduce the need for artificial lighting, increase workers productivity, customers’ satisfaction and consequently improve sales. However, excessive use of glazing and absence of lighting controls can contribute greatly to higher energy need for heating and cooling and cause undesired glare effects. Thus, optimizing the size, position and materials of external glazing, with the addition of deflectors and dynamic artificial lighting, can become key aspects in the design of sustainable low energy buildings. The purpose of this paper is to analyze daylight potential and energy performance of a hall-type commercial building, situated in the cold climate of Finland, by utilizing different combinations of skylights, windows and lighting controls. Design/methodology/approach: The authors have used computer simulations to estimate daylight and energy performance of a single floor commercial building in relation to various combinations of skylights and windows with variable glazing materials, light deflectors and zonal lighting controls. Findings: The results show that electric light energy saving potential ranges from a negligible 1.9 percent to a significant 58.6 percent in the case of glass skylights and wall windows using multi-zone lighting control. Total delivered energy ranges between increase of 1.5 and 21.2 percent in the cases with single zone lighting control and between decrease of 4.5 percent and increase of 4.5 percent in the cases with multi-zone control. The highest decrease in primary energy consumption was 2.2 percent for single zone and 17.6 percent for multi-zone lighting control. The research underlines the significant potential of electric light energy savings using daylighting strategies that, including the control of direct solar access for glare and internal gains, can be more than 50 percent. Originality/value: This research combines accurate daylight and energy assessment for commercial hall buildings based in cold climate region with multiple design variations. The novelty of this work is the consideration of interior elements, shelves and deflectors, in the calculations. This is made possible through the combined use of validated simulation platforms for detailed annual daylighting and electric lighting calculation (Radiance and Daysim) and energy analysis (IDA-ICE, Equa Simulation AB). This method allows to obtain a reliable assessment of the potential of using natural light sources in buildings.
On the behalf of reaching EU directive 2010/31/EU energy performance targets and fulfilling nearly zero-energy energy buildings (nZEB) requirements by the end of 2020, utilization of renewable energy sources becomes important. Renewable solar and ground energy can be efficiently utilized by a hybrid geothermal heat pump with a solar thermal storage, which is expected to yield high seasonal coefficient of performance (SCOP) making it attractive to consider in nZEB design. This numerical study investigates the impact of various ground heat exchangers and thermal storage options along with their possible combinations on heat pump plant heating/cooling performance in the design of commercial hall-type nZEB located in cold climate of Hämeenlinna, Finland. Components applied in a numerical study were energy piles, vertical boreholes (heat wells), solar collector and/or exhaust air heat as a thermal storage source. A whole year dynamic simulations were performed in IDA-ICE simulation environment, where detailed custom ground-source heat pump (GSHP) plants were modelled. Results revealed GSHP plant to be favorable heat source option in nZEB design. Application of thermal storage enabled to reduce energy piles field by more than two times. Proposed exhaust air thermal storage option performed highly efficient in comparison to solar thermal storage.Peer reviewe
16 September 2016 in Journal of Building Performance Simulation
This study analyses which building parameters contribute the most to overheating in dwellings and which properties will make a room ‘critical’, to be chosen for compliance assessment procedure through temperature simulation, as required in Estonia for new residential buildings. Indoor temperature measurements, conducted in 18 apartments from 16 apartment buildings, show clear evidence of overheating. Compliance assessment of 25 new buildings were conducted using IDA-ICE software. The analysed sample consisted of typical multi-storeyed buildings with mainly massive concrete structures. From the simulated buildings, 68% did not meet the requirements, showing that this relatively new building code requirement was not fully established in practice. Results of the analysis indicate that the requirement in apartment buildings is achievable without cooling, if passive measures are properly applied. Recommendations are given to designers, as well as policy-makers, to improve the situation in the residential building sector.