Ganapati Bhat

Dr. Ganapati Bhat

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2017 in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
Verified
Journal Article
Open access
GBGanapati Bhat
Ganapati Bhat
GSGaurav Singla
Gaurav Singla
AUAli K. Unver
Ali K. Unver
UOUmit Ogras
Umit Ogras
State-of-the-art mobile platforms are powered by heterogeneous system-on-chips that integrate multiple CPU cores, a GPU, and many specialized processors. Competitive performance on these platforms comes at the expense of increased power density due to their small form factor. Consequently, the skin temperature, which can degrade the experience, becomes a limiting factor. Since using a fan is not a viable solution for hand-held devices, there is a strong need for dynamic thermal and power management (DTPM) algorithms that can regulate temperature with minimal performance impact. This paper presents a DTPM algorithm, which uses a practical temperature prediction methodology based on system identification. The proposed algorithm dynamically computes a power budget using the predicted temperature. This budget is used to throttle the frequency and number of cores to avoid temperature violations with minimal impact on the system performance. Our experimental measurements on two different octa-core big.LITTLE processors and common Android applications demonstrate that the proposed technique predicts the temperature with less than 5% error across all benchmarks. Using this prediction, the proposed DTPM algorithm successfully regulates the maximum temperature and decreases the temperature violations by one order of magnitude while also reducing the total power consumption on average by 7% compared with the default solution.

18 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GBGanapati Bhat
Ganapati Bhat
NTNicholas Tran
Nicholas Tran
HSHolly A. Shill
Holly A. Shill
UOUmit Ogras
Umit Ogras
Human activity recognition (HAR) is growing in popularity due to its wide-ranging applications in patient rehabilitation and movement disorders. HAR approaches typically start with collecting sensor data for the activities under consideration and then develop algorithms using the dataset. As such, the success of algorithms for HAR depends on the availability and quality of datasets. Most of the existing work on HAR uses data from inertial sensors on wearable devices or smartphones to design HAR algorithms. However, inertial sensors exhibit high noise that makes it difficult to segment the data and classify the activities. Furthermore, existing approaches typically do not make their data available publicly, which makes it difficult or impossible to obtain comparisons of HAR approaches. To address these issues, we present wearable HAR (w-HAR) which contains labeled data of seven activities from 22 users. Our dataset’s unique aspect is the integration of data from inertial and wearable stretch sensors, thus providing two modalities of activity information. The wearable stretch sensor data allows us to create variable-length segment data and ensure that each segment contains a single activity. We also provide a HAR framework to use w-HAR to classify the activities. To this end, we first perform a design space exploration to choose a neural network architecture for activity classification. Then, we use two online learning algorithms to adapt the classifier to users whose data are not included at design time. Experiments on the w-HAR dataset show that our framework achieves 95% accuracy while the online learning algorithms improve the accuracy by as much as 40%.

31 January 2023 in ACM Transactions on Computing for Healthcare
Verified
Journal Article
Open access
SASizhe An
Sizhe An
GBGanapati Bhat
Ganapati Bhat
SGSuat Gumussoy
Suat Gumussoy
UOUmit Ogras
Umit Ogras
Human activity recognition (HAR) has increased in recent years due to its applications in mobile health monitoring, activity recognition, and patient rehabilitation. The typical approach is training a HAR classifier offline with known users and then using the same classifier for new users. However, the accuracy for new users can be low with this approach if their activity patterns are different than those in the training data. At the same time, training from scratch for new users is not feasible for mobile applications due to the high computational cost and training time. To address this issue, we propose a HAR transfer learning framework with two components. First, a representational analysis reveals common features that can transfer across users and user-specific features that need to be customized. Using this insight, we transfer the reusable portion of the offline classifier to new users and fine-tune only the rest. Our experiments with five datasets show up to 43% accuracy improvement and 66% training time reduction when compared to the baseline without using transfer learning. Furthermore, measurements on the hardware platform reveal that the power and energy consumption decreased by 43% and 68%, respectively, while achieving the same or higher accuracy as training from scratch. Our code is released for reproducibility. 1

23 July 2019 in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
Verified
Journal Article
Closed access
SMSumit K Mandal
Sumit K Mandal
GBGanapati Bhat
Ganapati Bhat
CPChetan Arvind Patil
Chetan Arvind Patil
JDJanardhan Rao Doppa
Janardhan Rao Doppa
PPPartha Pratim Pande
Partha Pratim Pande
UOUmit Ogras
Umit Ogras
The complexity of heterogeneous mobile platforms is growing at a rate faster than our ability to manage them optimally at runtime. For example, state-of-the-art systems-on-chip (SoCs) enable controlling the type (Big/Little), number, and frequency of active cores. Managing these platforms becomes challenging with the increase in the type, number, and supported frequency levels of the cores. However, existing solutions used in mobile platforms still rely on simple heuristics based on the utilization of cores. This paper presents a novel and practical imitation learning (IL) framework for dynamically controlling the type (Big/Little), number, and the frequencies of active cores in heterogeneous mobile processors. We present efficient approaches for constructing an Oracle policy to optimize different objective functions, such as energy and performance per Watt (PPW). The Oracle policies enable us to design low-overhead power management policies that achieve near-optimal performance matching the Oracle. Experiments on a commercial platform with 19 benchmarks show on an average 101% PPW improvement compared to the default interactive governor.

30 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JPJaehyun Park
Jaehyun Park
GBGanapati Bhat
Ganapati Bhat
ANAnish NK
Anish NK
CGCemil Geyik
Cemil Geyik
UOUmit Ogras
Umit Ogras
Hyung Gyu LeeHyung Gyu Lee
Hyung Gyu Lee
Wearable internet of things (IoT) devices can enable a variety of biomedical applications, such as gesture recognition, health monitoring, and human activity tracking. Size and weight constraints limit the battery capacity, which leads to frequent charging requirements and user dissatisfaction. Minimizing the energy consumption not only alleviates this problem, but also paves the way for self-powered devices that operate on harvested energy. This paper considers an energy-optimal gesture recognition application that runs on energy-harvesting devices. We first formulate an optimization problem for maximizing the number of recognized gestures when energy budget and accuracy constraints are given. Next, we derive an analytical energy model from the power consumption measurements using a wearable IoT device prototype. Then, we prove that maximizing the number of recognized gestures is equivalent to minimizing the duration of gesture recognition. Finally, we utilize this result to construct an optimization technique that maximizes the number of gestures recognized under the energy budget constraints while satisfying the recognition accuracy requirements. Our extensive evaluations demonstrate that the proposed analytical model is valid for wearable IoT applications, and the optimization approach increases the number of recognized gestures by up to 2.4× compared to a manual optimization.

23 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RDRanadeep Deb
Ranadeep Deb
SASizhe An
Sizhe An
GBGanapati Bhat
Ganapati Bhat
HSHolly A. Shill
Holly A. Shill
UOUmit Ogras
Umit Ogras
Parkinson’s disease (PD) is a neurological disorder with complicated and disabling motor and non-motor symptoms. The complexity of PD pathology is amplified due to its dependency on patient diaries and the neurologist’s subjective assessment of clinical scales. A significant amount of recent research has explored new cost-effective and subjective assessment methods pertaining to PD symptoms to address this challenge. This article analyzes the application areas and use of mobile and wearable technology in PD research using the PRISMA methodology. Based on the published papers, we identify four significant fields of research: diagnosis, prognosis and monitoring, predicting response to treatment, and rehabilitation. Between January 2008 and December 2021, 31,718 articles were published in four databases: PubMed Central, Science Direct, IEEE Xplore, and MDPI. After removing unrelated articles, duplicate entries, non-English publications, and other articles that did not fulfill the selection criteria, we manually investigated 1559 articles in this review. Most of the articles (45%) were published during a recent four-year stretch (2018–2021), and 19% of the articles were published in 2021 alone. This trend reflects the research community’s growing interest in assessing PD with wearable devices, particularly in the last four years of the period under study. We conclude that there is a substantial and steady growth in the use of mobile technology in the PD contexts. We share our automated script and the detailed results with the public, making the review reproducible for future publications.