Airborne LiDAR produced large amounts of data for archaeological research over the past decade. Labeling this type of archaeological data is a tedious process. We used a data set from Pacunam LiDAR Initiative survey of lowland Maya region in Guatemala. The data set contains ancient Maya structures that were manually labeled, and ground verified to a large extent. We have built and compared two deep learning-based models, U-Net and Mask R-CNN, for semantic segmentation. The segmentation models were used in two tasks: identification of areas of ancient construction activity, and identification of the remnants of ancient Maya buildings. The U-Net based model performed better in both tasks and was capable of correctly identifying 60–66% of all objects, and 74–81% of medium sized objects. The quality of the resulting prediction was evaluated using a variety of quantifiers. Furthermore, we discuss the problems of re-purposing the archaeological style labeling for production of valid machine learning training sets. Ultimately, we outline the value of these models for archaeological research and present the road map to produce a useful decision support system for recognition of ancient objects in LiDAR data.
Certain post-thoracic surgery complications are monitored in a standard manner using methods that employ ionising radiation. A need to automatise the diagnostic procedure has now arisen following the clinical trial of a novel lung ultrasound examination procedure that can replace X-rays. Deep learning was used as a powerful tool for lung ultrasound analysis. We present a novel deep-learning method, automated M-mode classification, to detect the absence of lung sliding motion in lung ultrasound. Automated M-mode classification leverages semantic segmentation to select 2D slices across the temporal dimension of the video recording. These 2D slices are the input for a convolutional neural network, and the output of the neural network indicates the presence or absence of lung sliding in the given time slot. We aggregate the partial predictions over the entire video recording to determine whether the subject has developed post-surgery complications. With a 64-frame version of this architecture, we detected lung sliding on average with a balanced accuracy of 89%, sensitivity of 82%, and specificity of 92%. Automated M-mode classification is suitable for lung sliding detection from clinical lung ultrasound videos. Furthermore, in lung ultrasound videos, we recommend using time windows between 0.53 and 2.13 s for the classification of lung sliding motion followed by aggregation.
New approaches and technologies like Internet of Things (IoT), cloud computing and Big Data are giving rise to another industrial revolution. We propose here an implementation of an industrial gateway architecture adopting the idea of IoT, intelligent methods, Machine-to-Machine and Cyber-Physical Systems. The proposed gateway creates a virtual representation of the physical world scanning the technological layer’s devices in real time. It creates a uniform communication interface for the heterogeneous technological layer, enables self-management of devices, diagnostics and self-reconfiguration to improve Quality of Service aided with cloud SCADA and MES services. We have tested the proposed gateway in an experimental setup with a programmable logic controller.
1 June 2015 in Acta Electrotechnica et Informatica
Background: Chest X-ray (CXR) remains the standard imaging modality in postoperative care after non-cardiac thoracic surgery. Lung ultrasound (LUS) showed promising results in CXR reduction. The aim of this review was to identify areas where the evaluation of LUS videos by artificial intelligence could improve the implementation of LUS in thoracic surgery. Methods: A literature review of the replacement of the CXR by LUS after thoracic surgery and the evaluation of LUS videos by artificial intelligence after thoracic surgery was conducted in Medline. Results: Here, eight out of 10 reviewed studies evaluating LUS in CXR reduction showed that LUS can reduce CXR without a negative impact on patient outcome after thoracic surgery. No studies on the evaluation of LUS signs by artificial intelligence after thoracic surgery were found. Conclusion: LUS can reduce CXR after thoracic surgery. We presume that artificial intelligence could help increase the LUS accuracy, objectify the LUS findings, shorten the learning curve, and decrease the number of inconclusive results. To confirm this assumption, clinical trials are necessary. This research is funded by the Slovak Research and Development Agency, grant number APVV 20-0232.