Rocio Perez

Dr. Rocio Perez

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2021 in ACS Applied Polymer Materials
Verified
Journal Article
Open access
RPRocio Perez
Rocio Perez
CACaitlan E. Ayala
Caitlan E. Ayala
MOMichelle M. Opiri
Michelle M. Opiri
AEAbdulrahman Ezzir
Abdulrahman Ezzir
Guoqiang LiGuoqiang Li
Guoqiang Li
Isiah WarnerIsiah Warner
Isiah Warner
Herein, a solvent-based green recycling procedure is reported for recycling thermoset epoxy resins (TERs) and carbon fiber reinforced epoxy composites (CFRECs) employing ionic liquids (ILs) and alcohols under mild conditions. With melting points less than 100 °C, ILs are defined as organic salts, typically composed of bulky cations with organic or inorganic counteranions. As a result of their unique physical properties such as low vapor pressure, relatively high thermal stability, and multifunctional tunability, these solvents are often classified as “green solvents” as compared to traditional organic solvents. In this study, swelling and dissolution of TER are evaluated in the presence of pure alkyl-methyl-imidazolium ILs, alcohols, and various mixtures of these co-solvents to determine their swelling and depolymerization capacity at mild temperatures in the absence of catalysts. In these studies, three ILs with different alkyl lengths were evaluated: 1-butyl-3-methyl imidazolium chloride ([BMIm][Cl]), 1-hexyl-3-methyl imidazolium bromide ([HMIm][Br]), and 1-octyl-3-methyl imidazolium bromide ([OMIm][Br]) along with two alcohols: ethylene glycol (EG) and glycerol (Gly). The highest swelling capacity of TER at 150 °C was achieved by a combination of [BMIm][Cl] and EG. In addition, swelling and dissolution of TER were evaluated in the presence of several anion variants of 1-butyl-3-methyl-imidazolium ILs with EG. Complete dissolution of both TERs and CFRECs was achieved in 150 min (2.5 h) at 150 °C under atmospheric pressure. Finally, recovery and reuse of the recycled monomer after dissolution were examined. Recovered epoxy monomers employed to synthesize a recycled TER exhibited similar mechanical properties to the parent TER. In addition, it was demonstrated that carbon fibers could be successfully recovered from CFREC using the recycling method detailed in this manuscript.

7 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DBDavid Bwambok
David Bwambok
NSNoureen Siraj
Noureen Siraj
SMSamantha Macchi
Samantha Macchi
NLNathaniel Larm
Nathaniel Larm
GBGary A. Baker
Gary A. Baker
SFSayo Fakayode
Sayo Fakayode
Quality checks, assessments, and the assurance of food products, raw materials, and food ingredients is critically important to ensure the safeguard of foods of high quality for safety and public health. Nevertheless, quality checks, assessments, and the assurance of food products along distribution and supply chains is impacted by various challenges. For instance, the development of portable, sensitive, low-cost, and robust instrumentation that is capable of real-time, accurate, and sensitive analysis, quality checks, assessments, and the assurance of food products in the field and/or in the production line in a food manufacturing industry is a major technological and analytical challenge. Other significant challenges include analytical method development, method validation strategies, and the non-availability of reference materials and/or standards for emerging food contaminants. The simplicity, portability, non-invasive, non-destructive properties, and low-cost of NIR spectrometers, make them appealing and desirable instruments of choice for rapid quality checks, assessments and assurances of food products, raw materials, and ingredients. This review article surveys literature and examines current challenges and breakthroughs in quality checks and the assessment of a variety of food products, raw materials, and ingredients. Specifically, recent technological innovations and notable advances in quartz crystal microbalances (QCM), electroanalytical techniques, and near infrared (NIR) spectroscopic instrument development in the quality assessment of selected food products, and the analysis of food raw materials and ingredients for foodborne pathogen detection between January 2019 and July 2020 are highlighted. In addition, chemometric approaches and multivariate analyses of spectral data for NIR instrumental calibration and sample analyses for quality assessments and assurances of selected food products and electrochemical methods for foodborne pathogen detection are discussed. Moreover, this review provides insight into the future trajectory of innovative technological developments in QCM, electroanalytical techniques, NIR spectroscopy, and multivariate analyses relating to general applications for the quality assessment of food products.

24 June 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
RPRocio Perez
Rocio Perez
CACaitlan E. Ayala
Caitlan E. Ayala
JPJong-Yoon Park
Jong-Yoon Park
JCJin W. Choi
Jin W. Choi
Isiah WarnerIsiah Warner
Isiah Warner
Volatile organic compounds (VOCs) that evaporate under standard atmospheric conditions are of growing concern. This is because it is well established that VOCs represent major contamination risks since release of these compounds into the atmosphere can contribute to global warming, and thus, can also be detrimental to the overall health of worldwide populations including plants, animals, and humans. Consequently, the detection, discrimination, and quantification of VOCs have become highly relevant areas of research over the past few decades. One method that has been and continues to be creatively developed for analyses of VOCs is the Quartz Crystal Microbalance (QCM). In this review, we summarize and analyze applications of QCM devices for the development of sensor arrays aimed at the detection of environmentally relevant VOCs. Herein, we also summarize applications of a variety of coatings, e.g., polymers, macrocycles, and ionic liquids that have been used and reported in the literature for surface modification in order to enhance sensing and selective detection of VOCs using quartz crystal resonators (QCRs) and thus QCM. In this review, we also summarize novel electronic systems that have been developed for improved QCM measurements.

17 July 2020 in Molecules
Verified
Journal Article
Open access
PDF file
NBNimisha Bhattarai
Nimisha Bhattarai
MCMi Chen
Mi Chen
RPRocio Perez
Rocio Perez
Sudhir RavulaSudhir Ravula
Sudhir Ravula
Robert StronginRobert Strongin
Robert Strongin
Isiah WarnerIsiah Warner
Isiah Warner
Rhodamine derivatives have been widely investigated for their mitochondrial targeting and chemotherapeutic properties that result from their lipophilic cationic structures. In previous research, we have found that conversion of Rhodamine 6G into nanoGUMBOS, i.e., nanomaterials derived from a group of uniform materials based on organic salts (GUMBOS), led to selective chemotherapeutic toxicity for cancer cells over normal cells. Herein, we investigate the chemotherapeutic activity of GUMBOS derived from four different rhodamine derivatives, two bearing an ester group, i.e., Rhodamine 123 (R123) and SNAFR-5, and two bearing a carboxylic acid group, i.e., rhodamine 110 (R110) and rhodamine B (RB). In this study, we evaluate (1) relative hydrophobicity via octanol–water partition coefficients, (2) cytotoxicity, and (3) cellular uptake in order to evaluate possible structure–activity relationships between these different compounds. Intriguingly, we found that while GUMBOS derived from R123 and SNAFR-5 formed nanoGUMBOS in aqueous medium, no distinct nanoparticles are observed for RB and R110 GUMBOS. Further investigation revealed that the relatively high water solubility of R110 and RB GUMBOS hinders nanoparticle formation. Subsequently, while R123 and SNAFR-5 displayed selective chemotherapeutic toxicity similar to that of previously investigated R6G nanoGUMBOS, the R110 and RB GUMBOS were lacking in this property. Additionally, the chemotherapeutic toxicities of R123 and SNAFR-5 nanoGUMBOS were also significantly greater than R110 and RB GUMBOS. Observed results were consistent with decreased cellular uptake of R110 and RB as compared to R123 and SNAFR-5 compounds. Moreover, these results are also consistent with previous observations that suggest that nanoparticle formation is critical to the observed selective chemotherapeutic properties as well as the chemotherapeutic efficacy of rhodamine nanoGUMBOS.

25 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
JPJong-Yoon Park
Jong-Yoon Park
RPRocio Perez
Rocio Perez
CACaitlan E. Ayala
Caitlan E. Ayala
SVStephanie R. Vaughan
Stephanie R. Vaughan
Isiah WarnerIsiah Warner
Isiah Warner
JCJin W. Choi
Jin W. Choi
The quartz crystal microbalance (QCM) has been widely used in laboratory settings as an analytical tool for recognizing and discriminating biological and chemical molecules of interest. As a result, recent studies have shown there to be considerable attention in practical applications of the QCM technique beyond the laboratory. However, most commercial QCM instruments are not suitable for off-laboratory usage. For field-deployable applications and in situ detection, the development of a portable QCM measurement system achieving comparable performance to benchtop instruments is highly desired. In this paper, we describe the development of a fully customizable, miniaturized, battery-powered, and cost-efficient QCM system employing a phase-locked loop (PLL) electronic circuit-based QCM measurement system. The performance of this developed system showed a minimum frequency resolution of approximately 0.22 Hz at 0.1 s measurement time. This novel, miniaturized system successfully demonstrated an ability to detect two common volatile organic compounds (VOCs), methanol and dichloromethane (DCM), and the obtained results were comparable to responses from a commercially available benchtop instrument.

22 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SVStephanie R. Vaughan
Stephanie R. Vaughan
RPRocio Perez
Rocio Perez
PCPratap Chhotaray
Pratap Chhotaray
Isiah WarnerIsiah Warner
Isiah Warner
Herein, we examine two sensing schemes for detection and discrimination of chlorinated volatile organic compounds (VOCs). In this work, phosphonium ionic liquids (ILs) were synthesized and vapor sensing properties examined and compared to phosphonium IL-polymer composites. Pure IL sensors were used to develop a QCM-based multisensory array (MSA), while IL-polymer composites were used to develop an MSA and virtual sensor arrays (VSAs). It was found that by employing the composite MSA, five chlorinated VOCs were accurately discriminated at 95.56%, which was an increase in accuracy as compared to pure ILs MSA (84.45%). Data acquired with two out of three VSAs allowed discrimination of chlorinated VOCs with 100% accuracy. These studies have provided greater insight into the benefits of incorporating polymers in coating materials for enhanced discrimination accuracies of QCM-based sensor arrays. To the best of our knowledge, this is the first report of a QCM-based VSA for discrimination of closely related chlorinated VOCs.