Wei Zhang

Dr. Wei Zhang

Surface Engineering Precision Institute, Cranfield University, MK43 0AL, UK
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2011 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
WZWei Zhang
Wei Zhang
DWDavid Webb
David Webb
Gang Ding PengGang Ding Peng
Gang Ding Peng
In this work we experimentally investigate the response time of humidity sensors based on polymer optical fiber Bragg gratings. By the use of etching with acetone we can control the poly (methyl methacrylate) based fiber in order to reduce the diffusion time of water into the polymer and hence speed up the relative wavelength change caused by humidity variations. A much improved response time of 12 minutes for humidity decrease and 7 minutes for humidity increase, has been achieved by using a polymer optical fiber Bragg grating with a reduced diameter of 135 microns.

1 September 2000 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
GYG. Yu
G. Yu
WZWei Zhang
Wei Zhang
JWJ.A.R. Williams
J.A.R. Williams
Measured results from a microwave photonic traversal filter exploiting fiber Bragg grating (FBG) arrays and achieving a high-performance tunable bandpass microwave response are presented. Tuning is affected by changing the optical carrier wavelength to select the operating gratings, and the high-quality frequency response is obtained by weighting the reflections of the gratings. This experiment demonstrates that sophisticated passive signal processing functionality can be achieved practically using FBGs.

29 April 2010 in Electronics Letters
Verified
Journal Article
Closed access
CZC. Zhang
C. Zhang
WZWei Zhang
Wei Zhang
DWDavid Webb
David Webb
Gang Ding PengGang Ding Peng
Gang Ding Peng
An optical fibre sensor system for humidity and temperature, comprising two Bragg gratings recorded in silica and polymer fibre, has been characterised. The response of this system is very well conditioned (2-norm condition number = 8.8) and consequently uncertainties in wavelength measurement do not lead to large errors in the recovered humidity and temperature.

14 May 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
WZWei Zhang
Wei Zhang
DWDavid Webb
David Webb
The humidity response of poly(methyl methacrylate) (PMMA)-based optical fiber Bragg gratings (POFBGs) has been studied. The characteristic wavelength of the grating is modulated by water absorption-induced swelling and refractive index change in the fiber. This work indicates that anisotropic expansion may exist in PMMA optical fiber, reducing the humidity responsivity of the grating and introducing uncertainty in the responsivity from fiber to fiber. By pre-straining a grating, one can get rid of this uncertainty and simultaneously improve the POFBG response time.

25 November 1999 in Electronics Letters
Verified
Journal Article
Closed access
WZWei Zhang
Wei Zhang
JWJ.A.R. Williams
J.A.R. Williams
IBI. Bennion
I. Bennion
The authors propose a novel technique for overcoming the limitation of the frequency response of an optical fibre delay line filter imposed by optical coherence. A high birefringence fibre based filter is demonstrated, giving a response free of optical interference noise and tunable by temperature.

1 January 2004 in Optics Express
Verified
Journal Article
Closed access
PDF file
DLDejiao Lin
Dejiao Lin
XJXiangqian Jiang
Xiangqian Jiang
FXFang Xie
Fang Xie
WZWei Zhang
Wei Zhang
LZLin Zhang
Lin Zhang
IBIan Bennion
Ian Bennion
We propose a self-reference multiplexed fibre interferometer (MFI) by using a tunable laser and fibre Bragg grating (FBG). The optical measurement system multiplexes two Michelson fibre interferometers with shared optical path in the main part of optical system. One fibre optic interferometer is used as a reference interferometer to monitor and control the high accuracy of the measurement system under environmental perturbations. The other is used as a measurement interferometer to obtain information from the target. An active phase tracking homodyne (APTH) technique is applied for signal processing to achieve high resolution. MFI can be utilised for high precision absolute displacement measurement with different combination of wavelengths from the tuneable laser. By means of Wavelength-Division-Multiplexing (WDM) technique, MFI is also capable of realising on-line surface measurement, in which traditional stylus scanning is replaced by spatial light-wave scanning so as to greatly improve the measurement speed and robustness.