WESPs (Wet Electrostatic precipitators) are mainly installed in industries and factories where PM (particulate matter) is primarily generated. Such a wet type WESPs exhibits very excellent performance by showing a PM collection efficiency of 97 to 99%, but the PM collection efficiency may decrease rapidly due to a situation in which the dust collector and the discharge electrode is corroded by water. Thus, developing technology to predict efficient PM collection in the design and operation of WESPs is critical. Previous studies have mainly developed machine learning-based models to predict atmospheric PM concentrations using data measured by meteorological agencies. However, the analysis of models for predicting the dust collection efficiency of WESPs installed in factories and industrial facilities is insufficient. In this study, a WESPs was installed, and PM collection experiments were conducted. Nonlinear data such as operating conditions and PM measurements were collected, and ensemble PM collection efficiency prediction models were developed. According to the research results, the random forest model yielded excellent performance, with the best results achieved when the target was PM 7: R2, MAE, and MSE scores of 0.956, 0.747, and 1.748, respectively.
In this study, a modified design of a two-switch buck-boost (TSBB) converter is proposed to improve power efficiency using fewer conduction components, and the optimal power range is measured. The proposed TSBB converter operates in three topologies: buck, boost, and buck-boost, like the conventional TSBB converter. However, the proposed converter improves the power efficiency in the buck and buck-boost topologies by decreasing conduction loss using the diode in the switch-off section while maintaining the same number of semiconductors as that in the conventional TSBB converter. The power efficiency of the buck topology improves for the power range 10–80 W in the constant voltage (CV) and constant current (CC) modes; it increases on average by 0.75–1.36% and 0.83–2.27% in the CV and CC modes, respectively. The power efficiency of the buck-boost topology step-down improves for the 10–80 W in all modes. This increases the average by 0.73–0.99% and 3.33–4.75% in the CV and CC modes, respectively. The power efficiency of the buck-boost topology step-up increases on average by 1.65–2.00% for 10–80 W in the CV mode. In the CC mode, it increases by 2.17–2.77% on average for 10–50 W.
Wildfires are a critical global threat, emphasizing the need for efficient detection systems capable of identifying fires and distinguishing fire-related from non-fire events in their early stages. This study integrates the swintransformer into the Faster R-CNN backbone to overcome challenges in detecting small flames and smoke and distinguishing complex scenarios like fog/haze and chimney smoke. The proposed model was evaluated using a dataset comprising five classes: flames, smoke, clouds, fog/haze, and chimney smoke. Experimental results demonstrate that swintransformer-based models outperform ResNet-based Faster R-CNN models, achieving a maximum mAP50 of 0.841 with the swintransformer-based model. The model exhibited superior performance in detecting small and dynamic objects while reducing misclassification rates between similar classes, such as smoke and chimney smoke. Precision–recall analysis further validated the model’s robustness across diverse scenarios. However, slightly lower recall for specific classes and a lower FPS compared to ResNet models suggest a need for further optimization for real-time applications. This study highlights the swintransformer’s potential to enhance wildfire detection systems by addressing fire and non-fire events effectively. Future research will focus on optimizing its real-time performance and improving its recall for challenging scenarios, thereby contributing to the development of robust and reliable wildfire detection systems.
This paper proposes a new high-performance light-emitting diode (LED) converter with separation of the AC and DC driving parts for a T8 LED tube. The proposed LED converter is mounted at the end of the LED tube in G13 base and G13 base dummy. The separation of the AC and DC driving parts enhances the light uniformity of the LED tube by securing the optical distance between the optic cover and light source. The AC driving part was designed to be inserted in a G13 base and was connected with the DC driving part through an LED module. The proposed LED converter is based on single-stage buck-boost topology and was designed for the operation at 19 W for a 1200 mm T8 LED tube. The proposed LED converter is very small and has fewer parts than other LED converters but still has high performance. The measurement results of the proposed LED converter show that the line regulation of the LED output current is less than 3.4% at 100-240 VAC and achieves high circuit efficiency (>89%), high power factor (>0.93), and low total harmonic distortion (<;9%). In addition, all the current harmonics of the converter meet the requirements of the IEC 61000-3-2 Class C standards for high-performance LED lighting applications.
This study is about an improved high-quality light-emitting diode (LED) converter for a T8 LED tube. The converter is separated into the AC driving circuit and DC driving circuit. Also, the LED tube was applied with an output ripple eliminator for the optical performance. The AC driving circuit and DC driving circuit are assembled at the end of the LED tube in a G13 base and a G13 base dummy, respectively, and the output ripple eliminator is located on an LED PCB. The proposed LED converter is founded on a SSBB (single-stage buck-boost) converter topology and was designed for 10 W operation for a 600 mm T8 LED tube. The light waveform of the LED tube was measured by a photosensor. The waveform had almost no ripple and was the same as a straight line. The average calculated percent flicker of the proposed LED converter was an average of 1.9% at 100 and 240 VAC, 50 and 60 Hz. The proposed converter has lower power efficiency than a conventional converter by 2.7% at 100–240 VAC, but it still has high power efficiency (>87%). The measurement results represent that the LED output current regulation is below 0.92% at 100–240 VAC and the converter obtains the power factor more than 0.84 and the total harmonic distortion is less than 14.3%. All of the current harmonics reach the IEC 61000-3-2 Class D standards for high-quality LED converters.
The electrical characteristics of low-voltage AC series arcs according to the load current (1, 3, and 5 A) were investigated under linear load conditions. A current waveform analysis identified nonlinear distortion, particularly the shoulder effect near zero-crossing regions. Frequency domain analyses using fast Fourier transform and total harmonic distortion (THD) demonstrated that harmonic current components are primarily concentrated in the low-frequency range below 3 kHz, where cumulative THD values saturate. As the load current increased, the THD delta between normal and arc conditions expanded from 1.526% to 2.084%, reflecting intensified nonlinearity. A detailed harmonic analysis revealed that the ninth harmonic maintains a consistent level deviation of approximately 15 dB, regardless of the current magnitude, serving as a robust indicator. Furthermore, the odd/even harmonic root mean square current ratio increased by up to 153.3% at 5 A, exhibiting a distinct feature for arc discrimination. This phenomenon is driven by the enhanced generation of odd harmonics and the sustained suppression of even harmonics owing to half-wave symmetry. In this research, the harmonic characteristics were quantified based on the load current, and the critical factors for effective arc fault discrimination in linear load environments were identified.