Zhong Yang

Zhong Yang


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XZXiaoli Zhang
Xiaoli Zhang
JZJinyong Zhang
Jinyong Zhang
FYFeng Yang
Feng Yang
WWWeiru Wu
Weiru Wu
HSHeqiang Sun
Heqiang Sun
ZYZhong Yang
Zhong Yang
The human gastric pathogen Helicobacter pylori (H. pylori) is a successful colonizer of the stomach. H. pylori infection strongly correlates with the development and progression of chronic gastritis, peptic ulcer disease, and gastric malignances. Vaccination is a promising strategy for preventing H. pylori infection. In this study, we evaluated the candidate antigens heat shock protein A (HspA) and H. pylori γ-glutamyl transpeptidase (GGT) for their effectiveness in development of subunit vaccines against H. pylori infection. rHspA, rGGT, and rHspA-GGT, a fusion protein based on HspA and GGT, were constructed and separately expressed in Escherichia coli and purified. Mice were then immunized intranasally with these proteins, with or without adjuvant. Immunized mice exhibited reduced bacterial colonization in stomach. The highest reduction in bacterial colonization was seen in mice immunized with the fusion protein rHspA-GGT when paired with the mucosal adjuvant LTB. Protection against H. pylori colonization was mediated by a strong systemic and localized humoral immune response, as well as a balanced Th1/Th2 cytokine response. In addition, immunofluorescence microscopy confirmed that rHspA-GGT specific rabbit antibodies were able to directly bind H. pylori in vitro. These results suggest antibodies are essential to the protective immunity associated with rHspA-GGT immunization. In summary, our results suggest HspA and GGT are promising vaccine candidates for protection against H. pylori infection.

19 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
XZXiaoling Zhang
Xiaoling Zhang
YLYan Liu
Yan Liu
TFTing Fan
Ting Fan
NHNing Hu
Ning Hu
ZYZhong Yang
Zhong Yang
Jun YangJun Yang
Jun Yang
A portable multichannel surface plasmon resonance (SPR) biosensor device is presented in this study. As an optical biosensor device, the core component of its light path is a semi-cylindrical prism, which is used as the coupling unit for the excitation of the SPR phenomena. Based on this prism, a wedge-shaped incident light beam including a continuous angle range (10°) is chosen to replace the commonly-used parallel light beam in traditional SPR devices, in which the incident angle is adjusted by a sophisticated mechanical system. Thus, complicated, cumbersome, and costly mechanical structures can be avoided in this design. Furthermore, the selection of a small and high-stability semiconductor laser and matrix CCD detector as well as a microfluidic system aids in the realization of a miniaturized and multichannel device. Several different samples were used to test the performance of this new device. For ethanol with different concentrations, the sensing response was of good linear relativity with the concentration (Y = 3.17143X + 2.81518, R2 = 0.97661). Mouse IgG and goat anti-mouse IgG were used as biological samples for immunological analysis, and BSA as the control group. Good specific recognition between mouse IgG and goat anti-mouse IgG has been achieved. The detection limit of antibody to antigen coated on the sensing surface was about 25 mg/L without surface modification.

1 December 2014 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
CCCesar Henrique Comin
Cesar Henrique Comin
XXXiaoyin Xu
Xiaoyin Xu
YWYaming Wang
Yaming Wang
LCLuciano da Fontoura Costa
Luciano da Fontoura Costa
ZYZhong Yang
Zhong Yang

29 April 2014 in Microscopy Research and Technique
Verified
Journal Article
Closed access
PDF file
YGYanen Guo
Yanen Guo
XXXiaoyin Xu
Xiaoyin Xu
YWYuanyuan Wang
Yuanyuan Wang
YWYaming Wang
Yaming Wang
SXShunren Xia
Shunren Xia
ZYZhong Yang
Zhong Yang

16 January 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
QWQiong Wang
Qiong Wang
XZXiaoling Zhang
Xiaoling Zhang
TFTing Fan
Ting Fan
ZYZhong Yang
Zhong Yang
XCXi Chen
Xi Chen
Jun YangJun Yang
Jun Yang
A giant unilamellar vesicle (GUV), with similar properties to cellular membrane, has been widely studied. Electroformation with its simplicity and accessibility has become the most common method for GUV production. In this work, GUV electroformation in devices with traditional 3D and new 2D electrode structures were studied with respect to the applied electric field. An optimal frequency (10 kHz in the 3D and 1 kHz in the 2D systems) was found in each system. A positive correlation was found between GUV formation and applied voltage in the 3D electrode system from 1 to 10 V. In the 2D electrode system, the yield of the generated GUV increased first but decreased later as voltage increased. These phenomena were further confirmed by numerically calculating the load that the lipid film experienced from the generated electroosmotic flow (EOF). The discrepancy between the experimental and numerical results of the 3D electrode system may be because the parameters that were adopted in the simulations are quite different from those of the lipid film in experiments. The lipid film was not involved in the simulation of the 2D system, and the numerical results matched well with the experiments.

9 November 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
YLYan Liu
Yan Liu
XZXiaoling Zhang
Xiaoling Zhang
MCMengdi Chen
Mengdi Chen
DYDanfen Yin
Danfen Yin
ZYZhong Yang
Zhong Yang
Jun YangJun Yang
Jun Yang
We present a new method of analyzing the deformability of fused cells in a microfluidic array device. Electrical stresses—generated by applying voltages (4–20 V) across discrete co-planar microelectrodes along the side walls of a microfluidic channel—have been used to electro-deform fused and unfused stem cells. Under an electro-deformation force induced by applying an alternating current (AC) signal, we observed significant electro-deformation phenomena. The experimental results show that the fused stem cells were stiffer than the unfused stem cells at a relatively low voltage (<16 V). However, at a relatively high voltage, the fused stem cells were more easily deformed than were the unfused stem cells. In addition, the electro-deformation process is modeled based on the Maxwell stress tensor and structural mechanics of cells. The theoretical results show that a positive correlation is found between the deformation of the cell and the applied voltage, which is consistent with the experimental results. Combined with a numerical analysis and experimental study, the results showed that the significant difference of the deformation ratio of the fused and unfused cells is not due to their size difference. This demonstrates that some other properties of cell membranes (such as the membrane structure) were also changed in the electrofusion process, in addition to the size modification of that process.