Florian Otte

Mr. Florian Otte


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DKDmitry Khakhulin
Dmitry Khakhulin
FOFlorian Otte
Florian Otte
MBMykola Biednov
Mykola Biednov
CBChristina Bömer
Christina Bömer
TCTae-Kyu Choi
Tae-Kyu Choi
Christian BresslerChristian Bressler
Christian Bressler
Time-resolved X-ray methods are widely used for monitoring transient intermediates over the course of photochemical reactions. Ultrafast X-ray absorption and emission spectroscopies as well as elastic X-ray scattering deliver detailed electronic and structural information on chemical dynamics in the solution phase. In this work, we describe the opportunities at the Femtosecond X-ray Experiments (FXE) instrument of European XFEL. Guided by the idea of combining spectroscopic and scattering techniques in one experiment, the FXE instrument has completed the initial commissioning phase for most of its components and performed first successful experiments within the baseline capabilities. This is demonstrated by its currently 115 fs (FWHM) temporal resolution to acquire ultrafast X-ray emission spectra by simultaneously recording iron Kα and Kβ lines, next to wide angle X-ray scattering patterns on a photoexcited aqueous solution of [Fe(bpy)3]2+, a transition metal model compound.

15 February 2022 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
MVMohammad Vakili
Mohammad Vakili
JBJohan Bielecki
Johan Bielecki
JKJuraj Knoška
Juraj Knoška
FOFlorian Otte
Florian Otte
HHHuijong Han
Huijong Han
JSJoachim Schulz
Joachim Schulz
The Sample Environment and Characterization (SEC) group of the European X-ray Free-Electron Laser (EuXFEL) develops sample delivery systems for the various scientific instruments, including systems for the injection of liquid samples that enable serial femtosecond X-ray crystallography (SFX) and single-particle imaging (SPI) experiments, among others. For rapid prototyping of various device types and materials, sub-micrometre precision 3D printers are used to address the specific experimental conditions of SFX and SPI by providing a large number of devices with reliable performance. This work presents the current pool of 3D printed liquid sample delivery devices, based on the two-photon polymerization (2PP) technique. These devices encompass gas dynamic virtual nozzles (GDVNs), mixing-GDVNs, high-viscosity extruders (HVEs) and electrospray conical capillary tips (CCTs) with highly reproducible geometric features that are suitable for time-resolved SFX and SPI experiments at XFEL facilities. Liquid sample injection setups and infrastructure on the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument are described, this being the instrument which is designated for biological structure determination at the EuXFEL.

9 August 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AGAndreas Galler
Andreas Galler
WGWojciech Gawelda
Wojciech Gawelda
MBMykola Biednov
Mykola Biednov
CBChristina Bomer
Christina Bomer
ABAlexander Britz
Alexander Britz
Christian BresslerChristian Bressler
Christian Bressler
The European X-ray Free-Electron Laser (EuXFEL) delivers extremely intense (>1012 photons pulse−1 and up to 27000 pulses s−1), ultrashort (<100 fs) and transversely coherent X-ray radiation, at a repetition rate of up to 4.5 MHz. Its unique X-ray beam parameters enable novel and groundbreaking experiments in ultrafast photochemistry and material sciences at the Femtosecond X-ray Experiments (FXE) scientific instrument. This paper provides an overview of the currently implemented experimental baseline instrumentation and its performance during the commissioning phase, and a preview of planned improvements. FXE's versatile instrumentation combines the simultaneous application of forward X-ray scattering and X-ray spectroscopy techniques with femtosecond time resolution. These methods will eventually permit exploitation of wide-angle X-ray scattering studies and X-ray emission spectroscopy, along with X-ray absorption spectroscopy, including resonant inelastic X-ray scattering and X-ray Raman scattering. A suite of ultrafast optical lasers throughout the UV–visible and near-IR ranges (extending up to mid-IR in the near future) with pulse length down to 15 fs, synchronized to the X-ray source, serve to initiate dynamic changes in the sample. Time-delayed hard X-ray pulses in the 5–20 keV range are used to probe the ensuing dynamic processes using the suite of X-ray probe tools. FXE is equipped with a primary monochromator, a primary and secondary single-shot spectrometer, and a timing tool to correct the residual timing jitter between laser and X-ray pulses.

29 April 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
MDMichael Diez
Michael Diez
HKHenning Kirchberg
Henning Kirchberg
AGAndreas Galler
Andreas Galler
SSSebastian Schulz
Sebastian Schulz
MBMykola Biednov
Mykola Biednov
Christian BresslerChristian Bressler
Christian Bressler
X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

13 July 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MBM. Biednov
M. Biednov
HYH. Yousef
H. Yousef
FOFlorian Otte
Florian Otte
TCT.-K. Choi
T.-K. Choi
YJY. Jiang
Y. Jiang
DKDmitry Khakhulin
Dmitry Khakhulin