Begoña Domenech-Amigot

Dr. Begoña Domenech-Amigot

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MSMar Sánchez-Brau
Mar Sánchez-Brau
BDBegoña Domenech-Amigot
Begoña Domenech-Amigot
FBFrancisco Brocal
Francisco Brocal
Jose Antonio QuesadaJose Antonio Quesada
Jose Antonio Quesada
MSMar Seguí-Crespo
Mar Seguí-Crespo
This cross-sectional study estimated computer vision syndrome (CVS) prevalence and analysed its relationship with video display terminal (VDT) exposure, as well as sociodemographic, refractive, environmental, and ergonomic characteristics in 109 presbyopic VDT workers wearing progressive addition lenses (PALs). Usual spectacles were measured with a lens analyser, and subjective refraction was performed by an optometrist. CVS was measured with the CVS-Q©. VDT exposure was collected. Ergonomic evaluations were conducted in a normal working posture looking at the screen. Air temperature and relative humidity were measured (thermohygrometer), and illumination was measured (luxmeter). Descriptive analysis and differences in CVS prevalence, as a function of the explanatory variables, were performed (chi-square test). Multivariate logistic regression was used to identify factors associated with CVS (OR and 95% CI). The mean age was 54.0 ± 4.8 years, and 43.1% were women. The mean hours of VDT use at work was 6.5 ± 1.3 hours/day. The prevalence of CVS was 74.3%. CVS was significantly associated with women (OR 3.40; 95% CI, 1.12–10.33), non-neutral neck posture (OR 3.27; 95% CI, 1.03–10.41) and altered workplace lighting (OR 3.64; 95% CI, 1.22–10.81). Providing training and information to workers regarding the importance of adequate lighting and ergonomic postures during VDT use is advised to decrease CVS and increase workplace quality of life.

4 May 2021 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
PDF file
MSMar Sánchez-Brau
Mar Sánchez-Brau
BDBegoña Domenech-Amigot
Begoña Domenech-Amigot
FBFrancisco Brocal
Francisco Brocal
MSMar Seguí‐Crespo
Mar Seguí‐Crespo
Purpose: To estimate the prevalence of computer vision syndrome (CVS) in presbyopic digital device workers using two ophthalmic progressive lens designs during the working day, and to analyse the association of CVS with sociodemographic, occupational, digital device exposure and refractive factors. Methods: This time series, quasi‐experimental design study included 69 presbyopic digital device workers (age range: 46–69 years; mean ± SD = 54.7 ± 5.0). All used desktop computers at their workplace. Progressive addition lenses (PALs) and occupational lenses were used for three months each. CVS was measured with the CVS‐Q © questionnaire before intervention (baseline) and at 1 week, 1 month and 3 months after wearing the lenses. A multivariate logistic regression model was used to identify the factors that were associated with an improved CVS‐Q © score. Results: 37.7% of the subjects were female and 78.3% were ametropes; 65.2% had advanced presbyopia. 56.2% used digital devices at work >6 h day −1 . The prevalence of CVS at baseline, after wearing PALs for three months and after three months of occupational lens wear was 68.1%, 33.3% and 18.8%, respectively. The mean CVS‐Q © score was lower with occupational lenses than with PALs ( p = 0.001). 40.6% of the digital device workers improved their CVS‐Q © score ≥2 points with the occupational lenses. Ametropes were less likely than emmetropes to improve with occupational lenses (OR = 0.27, p = 0.05). 89.8% of the sample workers were satisfied or very satisfied with the occupational lenses and 71% were similarly satisfied with the PALs. 73.9% chose the occupational lenses as their first choice of lens for digital device use, compared with 17.4% for PALs. Conclusions: Computer vision syndrome is reduced in presbyopic desktop computer workers wearing occupational lenses compared with PALs, especially in emmetropes.

7 May 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Julián Espinosa Julián Espinosa
Julián Espinosa
BDBegoña Domenech-Amigot
Begoña Domenech-Amigot
CVCarmen VÁZQUEZ Vazquez
Carmen VÁZQUEZ Vazquez
JPJorge Pérez
Jorge Pérez
DMDavid Mas
David Mas
The evaluation of eye blinking has been used for the diagnosis of neurological disorders and fatigue. Despite the extensive literature, no objective method has been found to analyze its kinematic and dynamic behavior. A non-contact technique based on the high-speed recording of the light reflected by the eyelid in the blinking process and the off-line processing of the sequence is presented. It allows for objectively determining the start and end of a blink, besides obtaining different physical magnitudes: position, speed, eyelid acceleration as well as the power, work and mechanical impulse developed by the muscles involved in the physiological process. The parameters derived from these magnitudes provide a unique set of features that can be used to biometric authentication. This possibility has been tested with a limited number of subjects with a correct identification rate of up to 99.7%, thus showing the potential application of the method.

14 January 2013 in Clinical and Experimental Optometry
Verified
Journal Article
Open access
PDF file
SVSilvia Vidal
Silvia Vidal
VVValentín Viqueira
Valentín Viqueira
DMDavid Mas
David Mas
BDBegoña Domenech-Amigot
Begoña Domenech-Amigot
Purpose The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra‐observer repeatability data were analysed using the intra‐class correlation coefficient (ICC) for a range of 95 per cent within‐subject standard deviation (SW) and the within‐subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra‐observer agreement, finding the best result in the central sector with an intra‐class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra‐class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra‐class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra‐class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra‐class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head‐rest than in the setup for retinal imaging.

27 May 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DMDavid Mas
David Mas
BDBegoña Domenech-Amigot
Begoña Domenech-Amigot
Julián Espinosa Julián Espinosa
Julián Espinosa
JPJorge Pérez
Jorge Pérez
CHConsuelo Hernández
Consuelo Hernández
CICarlos Illueca
Carlos Illueca
We present a noninvasive technique for high-speed measuring of eye retraction and eyelid position during blinking. The anterior chamber of the eye is illuminated by the slit lamp of a biomicroscope and eye dynamics during a blinking sequence are captured with a high-speed camera working at 500 frames per second. Digital image processing allows quantitative analysis of cornea and eyelid positions during the closing and opening phases of the blinking process. Our method allows simultaneous measuring of corneal retraction, duration of down and up phases, total blinking duration, and average and peak speeds of the eyelids in both phases, thus providing a complete analysis of the blink’s transversal motions.

10 November 2011 in Journal of Modern Optics
Verified
Journal Article
Closed access
JPJorge Perez
Jorge Perez
Julián Espinosa Julián Espinosa
Julián Espinosa
BDBegoña Domenech-Amigot
Begoña Domenech-Amigot
DMDavid Mas
David Mas
CICarlos Illueca
Carlos Illueca
Spontaneous eye blinking is a complex process, which implies the joint actions of the eyelid muscles and the eye globe. These actions provoke the eyelid closure and simultaneous eye retraction into the orbit. Recently, the authors presented a non-invasive technique for measuring both movements that permits calculating several parameters. Following the work from Malbouisson and co-workers, we have fitted the displacement curves of the eyelid to an analytical function and, additionally, we have extended the kinematic model to the eye retraction movements. As a result of the fitting, some dynamic parameters have been presented for the first time in the literature. This study can be easily extended to obtain relevant information about ocular biomechanical properties in physiological optics and provides results that may be of interest in neurophysiology, in order to understand the blinking mechanism.This work was supported by the Generalitat Valenciana project no. GV/2009/002 and by the Ministerio de Ciencia e Innovación through the project no. FIS2009-05639-E/FIS. J. Espinosa acknowledges the support of the Generalitat Valenciana through the project BEST/2010/209. D. Mas acknowledges the support of the Ministerio de Educacion through the project PR2009-0377