Hak Seung Lee

Dr. Hak Seung Lee

Medical Team, Medical AI Inc., Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
SKSi-Hyuck Kang
Si-Hyuck Kang
ICIn-Ho Chae
In-Ho Chae
JPJin-Joo Park
Jin-Joo Park
Hak Seung LeeHak Seung Lee
Hak Seung Lee
DKDo-Yoon Kang
Do-Yoon Kang
HKHyo-Soo Kim
Hyo-Soo Kim

27 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Hak Seung LeeHak Seung Lee
Hak Seung Lee
KPKyung Woo Park
Kyung Woo Park
JKJeehoon Kang
Jeehoon Kang
YKYou-Jeong Ki
You-Jeong Ki
MCMineok Chang
Mineok Chang
HKHyoSoo Kim
HyoSoo Kim
To demonstrate the association of the serum creatinine/serum cystatin C ratio (sarcopenia index, SI) with clinical outcomes including cardiovascular and bleeding risk in older patients who underwent percutaneous coronary intervention (PCI), we analyzed a multicenter nation-wide pooled registry. A total of 1086 older patients (65 years or older) who underwent PCI with second-generation drug-eluting stents (DES) were enrolled. The total population was divided into quartiles according to the SI, stratified by sex. The primary clinical outcomes were major adverse cardiovascular events (MACE, all-cause death, myocardial infarction and target lesion revascularization) and thrombolysis in myocardial infarction major and minor bleeding during a 3-year follow-up period. In the total population, MACE occurred within 3 years in 154 (14.2%) patients. The lowest SI quartile group (Q1) had a significantly higher 3-year MACE rate (Q1 vs. Q2–4; 23.1% vs. 11.2%, p < 0.001), while bleeding event rates were similar between the groups (Q1 vs. Q2–4; 2.6% vs. 2.2%, p = 0.656). The Cox proportional hazard model showed that lower SI is an independent predictor for MACE events (HR 2.23, 95% CI 1.62–3.07, p < 0.001). The SI, a surrogate for the degree of muscle mass, is associated with cardiovascular and non-cardiovascular death, but not with bleeding in older patients who underwent PCI.

1 February 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
JKJeehoon Kang
Jeehoon Kang
KPKyung Woo Park
Kyung Woo Park
Hak Seung LeeHak Seung Lee
Hak Seung Lee
CZChengbin Zheng
Chengbin Zheng
TRTae-Min Rhee
Tae-Min Rhee
HKHyoSoo Kim
HyoSoo Kim
Background: The clinical outcome after percutaneous coronary intervention (PCI) is affected by various clinical and procedural risk factors. We investigated the relative impact of clinical and procedural risks on clinical outcomes after PCI. Methods: A total of 13 172 patients were enrolled from the Grand-DES registry. The population was grouped into tertiles (high-, intermediate-, low-risk) according to the number of prespecified clinical and procedural risk factors, respectively. The primary end point was major adverse cardiac and cerebrovascular events (MACCE) at 3 years post-PCI. Results: MACCE occurred in 1109 (8.4%) patients during the follow-up period (median duration: 1126 days). Compared with procedural risk, clinical risk showed superior predictive power (area under the curve: 0.678 versus 0.570, P <0.001, for clinical and procedural risks, respectively) and greater magnitude of effect in the multivariate analysis for MACCE (Clinical risk: hazard ratio, 1.953 [95% CI, 1.809–2.109], P <0.001; procedural risk: hazard ratio, 1.240 [95% CI, 1.154–1.331], P <0.001). In subgroup analyses within each clinical risk tertile, procedural risk had no significant impact on MACCE in the lowest clinical risk tertile. An annual landmark analysis revealed that clinical and procedural risks were both significant predictors of MACCE, which occurred within the first and second year post-PCI. However, for MACCE occurring in the third year post-PCI, only clinical risk but not procedural risk was a significant predictor of events. Conclusions: Clinical and procedural risks were both significant predictors for ischemic clinical events in patients undergoing PCI. However, clinical risk had a greater and more prolonged effect on outcomes than procedural risk. Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03507205.

1 December 2017 in European Journal of Internal Medicine
Verified
Journal Article
Closed access
MCMyung-Jin Cha
Myung-Jin Cha
Hak Seung LeeHak Seung Lee
Hak Seung Lee
HKHyue Mee Kim
Hyue Mee Kim
JJJi-Hyun Jung
Ji-Hyun Jung
ECEue-Keun Choi
Eue-Keun Choi
SOSeil Oh
Seil Oh

27 June 2019 in Cardiology Journal
Verified
Journal Article
Open access
PDF file
Hak Seung LeeHak Seung Lee
Hak Seung Lee
JLJoo Myung Lee
Joo Myung Lee
CNChang-Wook Nam
Chang-Wook Nam
ESEun-Seok Shin
Eun-Seok Shin
JDJoon-Hyung Doh
Joon-Hyung Doh
BKBon-Kwon Koo
Bon-Kwon Koo
Background: Currently, invasive physiologic assessment such as fractional flow reserve is widely used worldwide with different adoption rates around the globe. Patient characteristics and physician preferences often differ in the Asia-Pacific (APAC) region with respect to treatment strategy, techniques, lesion complexity, access to coronary physiology and imaging devices, as well as patient management. Thus, there is a need to construct a consensus document on recommendations for use of physiology-guided percutaneous coronary intervention (PCI) in APAC populations. This document serves as an overview of recommendations describing the best practices for APAC populations to achieve more consistent and optimal clinical outcomes. Methods and Results: A comprehensive multiple-choice questionnaire was provided to 20 interventional cardiologists from 10 countries in the APAC region. Clinical evidence, tips and techniques, and clinical situations for the use of physiology-guided PCI in APAC were reviewed and used to propose key recommendations. There are suggestions to continue to develop evidence for lesion and patient types that will benefit from physiology, develop directions for future research in health economics and local data, develop appropriate use criteria in different countries, and emphasize the importance of education of all stakeholders. A consensus recommendation to enhance the penetration of invasive physiology-based therapy was to adopt the 5E approach: Evidence, Education, Expand hardware, Economics and Expert consensus. Conclusions: This consensus document and recommendations support interventional fellows and cardiologists, hospital administrators, patients, and medical device companies to build confidence and encourage wider imple­mentation of invasive coronary physiology-guided therapy in the APAC region. Background: Currently, invasive physiologic assessment such as fractional flow reserve is widely used worldwide with different adoption rates around the globe. Patient characteristics and physician preferences often differ in the Asia-Pacific (APAC) region with respect to treatment strategy, techniques, lesion complexity, access to coronary physiology and imaging devices, as well as patient management. Thus, there is a need to construct a consensus document on recommendations for use of physiology-guided percutaneous coronary intervention (PCI) in APAC populations. This document serves as an overview of recommendations describing the best practices for APAC populations to achieve more consistent and optimal clinical outcomes. Methods and Results: A comprehensive multiple-choice questionnaire was provided to 20 interventional cardiologists from 10 countries in the APAC region. Clinical evidence, tips and techniques, and clinical situations for the use of physiology-guided PCI in APAC were reviewed and used to propose key recommendations. There are suggestions to continue to develop evidence for lesion and patient types that will benefit from physiology, develop directions for future research in health economics and local data, develop appropriate use criteria in different countries, and emphasize the importance of education of all stakeholders. A consensus recommendation to enhance the penetration of invasive physiology-based therapy was to adopt the 5E approach: Evidence, Education, Expand hardware, Economics and Expert consensus. Conclusions: This consensus document and recommendations support interventional fellows and cardiologists, hospital administrators, patients, and medical device companies to build confidence and encourage wider imple­mentation of invasive coronary physiology-guided therapy in the APAC region.

4 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
YKYou-Jeong Ki
You-Jeong Ki
JKJeehoon Kang
Jeehoon Kang
Hak Seung LeeHak Seung Lee
Hak Seung Lee
MCMineok Chang
Mineok Chang
JHJung-Kyu Han
Jung-Kyu Han
HKHyoSoo Kim
HyoSoo Kim
Paravalvular leak (PVL) is an important complication of transcatheter aortic valve implantation (TAVI) and is associated with poor prognosis. We aimed to identify the risk factors for PVL after TAVI including patient (calcium amount or location), device (leakage-proof or not), and procedural (oversizing index (OI)) factors. The primary outcome was mild or greater PVL at 1-month follow-up echocardiography. Overall, 238 patients who underwent TAVI using eight types of valves (Edwards Sapien, Sapien XT, Sapien 3, CoreValve, Evolut R, Evolut PRO, Lotus, and Lotus Edge) were included. The incidence of significant PVL (≥mild PVL) was 24.4%. Although patient factors (calcification of valve) were not predictors of PVL, valve without leakage-proof function (Edwards Sapien, Sapien XT, and CoreValve) was a significant predictor of PVL (adjusted odds ratio, 3.194, 95% CI, 1.620–6.299). Furthermore, OI has a significant protective role against PVL (PVL increased by 45% when OI decreased by 5%). The best cutoff value of OI to predict the absence of PVL was ≥17.6% for the Evolut system and ≥10.2% for the Sapien system. The predictors of PVL after TAVI included factors from the device (valve without leakage-proof function) and procedure (under-sizing). In patients with a high risk of PVL, the procedure should be optimized using valves with leakage-proof function and adequate OI.