Wendong Zhang

Prof. Wendong Zhang


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
RWRenxin Wang
Renxin Wang
WSWei Shen
Wei Shen
WZWenjun Zhang
Wenjun Zhang
JSJinlong Song
Jinlong Song
NLNansong Li
Nansong Li
WZWendong Zhang
Wendong Zhang
Detecting low-frequency underwater acoustic signals can be a challenge for marine applications. Inspired by the notably strong response of the auditory organs of pectis jellyfish to ultralow frequencies, a kind of otolith-inspired vector hydrophone (OVH) is developed, enabled by hollow buoyant spheres atop cilia. Full parametric analysis is performed to optimize the cilium structure in order to balance the resonance frequency and sensitivity. After the structural parameters of the OVH are determined, the stress distributions of various vector hydrophones are simulated and analyzed. The shock resistance of the OVH is also investigated. Finally, the OVH is fabricated and calibrated. The receiving sensitivity of the OVH is measured to be as high as −202.1 dB@100 Hz (0 dB@1 V/μPa), and the average equivalent pressure sensitivity over the frequency range of interest of the OVH reaches −173.8 dB when the frequency ranges from 20 to 200 Hz. The 3 dB polar width of the directivity pattern for the OVH is measured as 87°. Moreover, the OVH is demonstrated to operate under 10 MPa hydrostatic pressure. These results show that the OVH is promising in low-frequency underwater acoustic detection.

1 March 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JHJie Hu
Jie Hu
YSYongjiao Sun
Yongjiao Sun
YXYan Xue
Yan Xue
MZMeng Zhang
Meng Zhang
PLPengwei Li
Pengwei Li
YCYong Chen
Yong Chen

22 January 2015 in Critical Reviews in Biotechnology
Verified
Journal Article
Closed access
Shengbo SangShengbo Sang
Shengbo Sang
YWYajun Wang
Yajun Wang
QFQiliang Feng
Qiliang Feng
YWYe Wei
Ye Wei
JJJianlong Ji
Jianlong Ji
WZWendong Zhang
Wendong Zhang
The detection techniques used in biosensors can be broadly classified into label-based and label-free. Label-based detection relies on the specific properties of labels for detecting a particular target. In contrast, label-free detection is suitable for the target molecules that are not labeled or the screening of analytes which are not easy to tag. Also, more types of label-free biosensors have emerged with developments in biotechnology. The latest developed techniques in label-free biosensors, such as field-effect transistors-based biosensors including carbon nanotube field-effect transistor biosensors, graphene field-effect transistor biosensors and silicon nanowire field-effect transistor biosensors, magnetoelastic biosensors, optical-based biosensors, surface stress-based biosensors and other type of biosensors based on the nanotechnology are discussed. The sensing principles, configurations, sensing performance, applications, advantages and restriction of different label-free based biosensors are considered and discussed in this review. Most concepts included in this survey could certainly be applied to the development of this kind of biosensor in the future.

5 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZhidong Zhang
Zhidong Zhang
LLLiang Luo
Liang Luo
CXChenyang Xue
Chenyang Xue
WZWendong Zhang
Wendong Zhang
SYShubin Yan
Shubin Yan
A refractive index sensor based on metal-insulator-metal (MIM) waveguides coupled double rectangular cavities is proposed and investigated numerically using the finite element method (FEM). The transmission properties and refractive index sensitivity of various configurations of the sensor are systematically investigated. An asymmetric Fano resonance lineshape is observed in the transmission spectra of the sensor, which is induced by the interference between a broad resonance mode in one rectangular and a narrow one in the other. The effect of various structural parameters on the Fano resonance and the refractive index sensitivity of the system based on Fano resonance is investigated. The proposed plasmonic refractive index sensor shows a maximum sensitivity of 596 nm/RIU.

1 March 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
ZZZhenting Zhao
Zhenting Zhao
YSYongjiao Sun
Yongjiao Sun
PLPengwei Li
Pengwei Li
JJJianlong Ji
Jianlong Ji
JHJie Hu
Jie Hu

6 April 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YTYue Tang
Yue Tang
ZZZhidong Zhang
Zhidong Zhang
RWRuibing Wang
Ruibing Wang
ZHZhenyin Hai
Zhenyin Hai
CXChenyang Xue
Chenyang Xue
SYShubin Yan
Shubin Yan
A surface plasmon polariton refractive index sensor based on Fano resonances in metal–insulator–metal (MIM) waveguides coupled with rectangular and ring resonators is proposed and numerically investigated using a finite element method. Fano resonances are observed in the transmission spectra, which result from the coupling between the narrow-band spectral response in the ring resonator and the broadband spectral response in the rectangular resonator. Results are analyzed using coupled-mode theory based on transmission line theory. The coupled mode theory is employed to explain the Fano resonance effect, and the analytical result is in good agreement with the simulation result. The results show that with an increase in the refractive index of the fill dielectric material in the slot of the system, the Fano resonance peak exhibits a remarkable red shift, and the highest value of sensitivity (S) is 1125 nm/RIU, RIU means refractive index unit. Furthermore, the coupled MIM waveguide structure can be integrated with other photonic devices at the chip scale. The results can provide a guide for future applications of this structure.