Xuesong Zhou

Xuesong Zhou


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
ZGZhiqiang Gao
Zhiqiang Gao
XZXuesong Zhou
Xuesong Zhou
ZHZhongjie Han
Zhongjie Han
The boundary stabilization problem of a star-shaped type II thermoelastic system is considered, where there is an non-uniform bounded disturbance at the control end. A time-varying extended state observer is proposed to estimate and cancel the disturbance, thereby largely removes the uncertainties and simplify the feedback control law design. The exponential stability is shown for the extended state observer, so is the well-posedness properties of the closed loop system, all based on the linear operator semigroup theory. Finally, it is shown that the disturbances can be attenuated and the resulting closed loop system can exponentially approach zero. Numerical simulations illustrate the effectiveness of the proposed control strategy.

13 April 2020 in IEEE Access
Verified
Journal Article
Open access
YMYoujie Ma
Youjie Ma
LTLong Tao
Long Tao
XZXuesong Zhou
Xuesong Zhou
XSXueqi Shi
Xueqi Shi
Wind energy, as a kind of renewable natural energy, is spread all over the world. It is one of the most widely used and promising green energy to adjust the energy structure. Therefore, wind energy conversion systems (WECSs) have captured a great deal of attention in renewable energy sources for the past few years. In order to improve the transient stability and deal with non-linearity, variable parameters, strong coupling, and multi-variables an linear active disturbance rejection control with correction link (LADRC-CL) strategy is proposed for the WECS based on the permanent magnet synchronous generator (PMSG). The LADRC-CL completes with a conventional PD control rule, the linear extended state observer (LESO) and a correction link. Its convergence, stability and disturbance rejection ability were analyzed in frequency domain. Furthermore, the mathematical model of the WECS is analyzed and part of the model information is written into the LESO matrix to effectively reduce the LESO observation burden. In an experiment, the control performance of the LADRC-CL was also tested under various operating conditions using the 3.6MW power unit full true wind field simulation experiment platform to verify the correctness, validity and reliability of the linear active disturbance rejection control with correction link.


10 February 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
CCChengpeng Chu
Chengpeng Chu
CDChao Dong
Chao Dong
Mingxing DuMingxing Du
Mingxing Du
XZXuesong Zhou
Xuesong Zhou
ZOZiwei Ouyang
Ziwei Ouyang
This article presents a method for monitoring the aging of insulate gate bipolar transistor (IGBT) module bond wires based on the spectrum characteristics of differential mode (DM) interference signals. The buck converter composed of IGBT modules is used as the device under test. The path of DM current in buck converter passes through the IGBT module, so the DM current is more suitable for monitoring the status of the module. The DM electromagnetic interference (EMI) in buck converter is mainly generated by the rapid decrease of the collector current, and the aging degree of bond wires is directly related to the DM EMI signal. The aging degree of bond wires inside IGBT module is monitored by the peak value of DM EMI signal in low frequency band. The experimental results show that the DM EMI amplitude of buck converter with aging IGBT module is larger than that of the buck converter with healthy IGBT module. The main advantage of the method proposed in this article is that it is independent of temperature and can realize the on-line accurate monitoring of the aging of the bond wires inside the IGBT module through the current probe under the actual working conditions.

4 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
XZXuesong Zhou
Xuesong Zhou
YZYongliang Zhou
Yongliang Zhou
YMYoujie Ma
Youjie Ma
LYLuyong Yang
Luyong Yang
XYXia Yang
Xia Yang
QLQian Liu
Qian Liu
In the permanent magnet synchronous generator (PMSG), the DC bus voltage fluctuates up and down under the influence of the load and power grid, which greatly affects the safe and reliable work of PMSG. In order to suppress the wide range fluctuation of DC bus voltage under disturbance and enhance its anti-disturbance performance, an optimized DC bus voltage control strategy is proposed by using the improved linear active disturbance rejection control (LADRC) in the voltage outer loop. By considering factors, such as load disturbance and grid voltage mutation as the total disturbance of the system, the improved reduced-order linear expansion state observer (RLSEO) is used to estimate and compensate the total disturbance, which greatly improves the stability of DC bus voltage. Firstly, the mathematical model of grid-side converter is established. On this basis, the LADRC control based on RLESO is designed, which reduces the phase lag of the linear extended state observer (LESO) and enhances the disturbance observation accuracy of the system. Then, a lead lag correction link is added to the total disturbance channel of RLESO to reduce the noise amplification effect of RLESO. Finally, the frequency domain characteristic analysis and stability proof of the improved LADRC control strategy are carried out. The simulation results show that the control strategy proposed in the article has a better control effect on the DC bus voltage.

2 September 2020 in IEEE Access
Verified
Journal Article
Open access
YMYoujie Ma
Youjie Ma
LYLuyong Yang
Luyong Yang
XZXuesong Zhou
Xuesong Zhou
XYXia Yang
Xia Yang
At present, which has gradually become a technical development trend that the energy storage grid-connected inverter system is connected to the grid to ensure the stable operation of the whole system. However, the stability of the energy storage system itself is also very important for the safe operation of the power grid. Therefore, improving the stability of grid-connected energy storage system is still the key technology of current research. Aiming at the strong coupling and low-voltage ride-through fault of grid-connected system, a second-order mathematical model of grid-connected control system is established. Based on its state space model, a linear extended state observer (LESO) for state observation and a linear state error feedback (LSEF) control law for disturbance estimation are designed. The second-order linear active disturbance rejection control (LADRC) is introduced into the voltage loop, the stability of the second-order LADRC controller is proved by the Lyapunov stability theory, and the stability conditions are given. Finally, the simulation model of the grid-connected energy storage system is built on the MATLAB / Simulink digital platform, and the low-voltage ride-through fault is designed on the grid-side. The simulation results show that the effect of the second-order LADRC control is better than that of the traditional PI control obviously, which reflects the superiority of the second-order LADRC in controlling the grid-side low-voltage ride-through fault.