Qian Liu

Dr. Qian Liu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
XZXuesong Zhou
Xuesong Zhou
YZYongliang Zhou
Yongliang Zhou
YMYoujie Ma
Youjie Ma
LYLuyong Yang
Luyong Yang
XYXia Yang
Xia Yang
QLQian Liu
Qian Liu
In the permanent magnet synchronous generator (PMSG), the DC bus voltage fluctuates up and down under the influence of the load and power grid, which greatly affects the safe and reliable work of PMSG. In order to suppress the wide range fluctuation of DC bus voltage under disturbance and enhance its anti-disturbance performance, an optimized DC bus voltage control strategy is proposed by using the improved linear active disturbance rejection control (LADRC) in the voltage outer loop. By considering factors, such as load disturbance and grid voltage mutation as the total disturbance of the system, the improved reduced-order linear expansion state observer (RLSEO) is used to estimate and compensate the total disturbance, which greatly improves the stability of DC bus voltage. Firstly, the mathematical model of grid-side converter is established. On this basis, the LADRC control based on RLESO is designed, which reduces the phase lag of the linear extended state observer (LESO) and enhances the disturbance observation accuracy of the system. Then, a lead lag correction link is added to the total disturbance channel of RLESO to reduce the noise amplification effect of RLESO. Finally, the frequency domain characteristic analysis and stability proof of the improved LADRC control strategy are carried out. The simulation results show that the control strategy proposed in the article has a better control effect on the DC bus voltage.

7 April 2021 in Electronics
Verified
Journal Article
Open access
PDF file
YMYoujie Ma
Youjie Ma
QLQian Liu
Qian Liu
YMYoujie Ma
Youjie Ma
QLQian Liu
Qian Liu
BXBingjie Xie
Bingjie Xie
To enhance the robust stability of the dc-link voltage in the photovoltaic (PV) grid-connected system, a modified linear active disturbance rejection control (LADRC)-based regulation strategy is presented in this paper. The proposed control strategy is equipped with the cascaded extended state observer, which can supplement the disturbance information not estimated by the conventional one, thereby achieving a relatively fast and accurate disturbance reconstruction. The tracking performance and disturbance rejection performance of the modified LADRC are discussed and studied in the frequency domain. Finally, the experimental results are provided to verify the theoretical analysis.

26 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
YMYoujie Ma
Youjie Ma
XZXuesong Zhou
Xuesong Zhou
YMYiujie Ma
Yiujie Ma
QLQian Liu
Qian Liu
YZYongliang Zhou
Yongliang Zhou
CYChangsheng Yuan
Changsheng Yuan
In wind power systems, LCL inverters have technical problems. First of all, they are non-linear systems and are no longer adapted to the superposition principle; secondly, the coupling is great; finally, it is easy to be interfered by the outside world, and the interference mainly comes from voltage fluctuations and nonlinear loads on the grid. Therefore, it is difficult to control the output result, and then the improved linear active disturbance rejection control (LADRC) is applied. The main improvement of the improved LADRC lies in the linear extended state observer (LESO). Introducing the total disturbance differential signal in LESO, and in order to improve the ability to suppress high-frequency noise, a series of first-order inertia link was applied. The analysis method in this article is mainly frequency domain analysis, under the condition of obtaining LADRC closed-loop transfer function and frequency band characteristics, theoretical analysis of LADRC tracking estimation ability, disturbance suppression ability, and stability. A large number of experimental simulation results verified the superiority of improving LADRC. The main manifestation is that the improved LADRC not only has a fast response speed but also has a strong ability to suppress disturbances and has a good noise suppression effect in high frequency bands.

5 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
YMYoujie Ma
Youjie Ma
LYLuyong Yang
Luyong Yang
XZXuesong Zhou
Xuesong Zhou
XYXia Yang
Xia Yang
YZYongliang Zhou
Yongliang Zhou
QLQian Liu
Qian Liu
The energy storage inverter system has the characteristics of nonlinearity, strong coupling, variable parameters, and flexible mode switching between parallel and off grid. In order to improve the control performance of the grid-side inverter of the energy storage system, an improved Linear Active Disturbance Rejection Control (LADRC) based on proportional differentiation is proposed to replace the traditional LADRC in the voltage outer loop control. In this paper, the observation gain coefficient of the sum of the disturbances of the traditional Linear Extended State Observer (LESO) is improved to a proportional differentiation link, which effectively reduces the degree of the disturbance observation amplitude drop and the phase lag, and increases the observation bandwidth of LESO. Compared with traditional LADRC, it not only improves the observation accuracy of LESO for disturbance, but also improves the anti-interference performance of LADRC. Finally, the control effects of improved LADRC and traditional LADRC on low-voltage ride-through at different degrees are analyzed and compared through simulation, which proves the rationality of the controller designed in this paper.