Survival among hemodialysis patients is disturbingly low, partly because vascular calcification (VC) and cardiovascular disease are highly prevalent. Elevated serum phosphorus (P) and calcium (Ca) levels play an essential role in the formation of VC events. The purpose of the current study was to reveal optical monitoring possibilities of serum P and Ca values during dialysis. Twenty-eight patients from Tallinn (Estonia) and Linköping (Sweden) were included in the study. The serum levels of Ca and P on the basis of optical information, i.e., absorbance and fluorescence of the spent dialysate (optical method) were assessed. Obtained levels were compared in means and SD. The mean serum level of Ca was 2.54 ± 0.21 and 2.53 ± 0.19 mmol/L; P levels varied between 1.08 ± 0.51 and 1.08 ± 0.48 mmol/L, measured in the laboratory and estimated by the optical method respectively. The levels achieved were not significantly different (p = 0.5). The Bland-Altman 95% limits of agreement between the two methods varied from −0.19 to 0.19 for Ca and from −0.37 to 0.37 in the case of P. In conclusion, optical monitoring of the spent dialysate for assessing the serum levels of Ca and P during dialysis seems to be feasible and could offer valuable and continuous information to medical staff.

1 August 2006 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
KLKai Lauri
Kai Lauri
RTRisto Tanner
Risto Tanner
MLMerike Luman
Merike Luman
JHJana Holmar
Jana Holmar
IFIvo Fridolin
Ivo Fridolin
Several on-line methods have been developed to standardize the assessment of dialysis adequacy. Earlier studies have demonstrated that on-line monitoring of total ultra violet (UV) absorbance in spent dialysate can be utilized to follow continuously a single hemodialysis session. The aim of this study was to investigate the contribution of different compounds, acting as chromophores, to the UV-absorbance in the spent dialysate in order to explain origin of the cumulative and integrated UV-absorbance measured by the optical dialysis adequacy sensor. Four uremic patients, during 12 hemodialysis treatments, were followed by the optical dialysis adequacy sensor using the wavelength of 280 mn. The dialysate samples were taken and analyzed using reversed phase high performance liquid chromatography (HPLC). The total number of detected peaks from the HPLC gradient separation profiles measured at the wavelength 280 nm for the samples collected 10 mm after the start of hemodialysis (MeanplusmnSD) was 38plusmn6. The relative contribution from the area of 10 main peaks to the total area of all detected peaks in percentage was 91.01plusmn2.52 %. The optical dialysis adequacy sensor provides continuous, on-line hemodialysis measurements and may immediately identify and alert to any deviations in the dialysis. Our study indicates that there exists a number of prevalent compounds that are the main cause of the cumulative and integrated UV- absorbance

1 August 2007
Verified
Conference Paper
Closed access
JHJana Holmar
Jana Holmar
KLKai Lauri
Kai Lauri
RTRisto Tanner
Risto Tanner
MLMerike Luman
Merike Luman
IFIvo Fridolin
Ivo Fridolin
A need for dialysate-based, on-line, continuous monitoring systems for the control of dialysis efficiency and the prevention of dialysis-associated complications is arisen due to increasing number of dialysis patients and related treatment quality requirements. The aim of this study was to investigate the wavelength dependence between the the ultraviolet (UV) absorbance in the spent dialysate and the retained solutes removed during the hemodialysis in order to explain possibilities to estimate removal of the solutes by the optical dialysis adequacy sensor. Ten uremic patients, during 30 hemodialysis treatments, were followed at the Department of Dialysis and Nephrology, North-Estonian Regional Hospital. The dialysate samples were taken and analyzed with spectrophotometer to get absorbance spectra. The results confirm previous studies considering similarity for the UV-spectrum on the spent dialysate samples during a single dialysis session indicating presence of the same type of chromophores in the spent dialysate removed from the patient's blood for different patients groups. At the same time the highest correlation in the spent dialysate for urea, creatinine, potassium, and phosphate was obtained at the wavelength 237 nm that is a new finding compared to earlier results. The highest correlation between the UV-absorbance and uric acid in the spent dialysate was obtained at the wavelength 294 nm. Presence of at least two different wavelength ranges may add selectivity for monitoring several compounds. Our study indicates that the technique has a potential to estimate the removal of retained substances.

1 September 2009 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
JHJana Holmar
Jana Holmar
FUFredrik Uhlin
Fredrik Uhlin
KLKai Lauri
Kai Lauri
RTRisto Tanner
Risto Tanner
MLMerike Luman
Merike Luman
IFIvo Fridolin
Ivo Fridolin
The aim of this study was to compare concentration measurements of uric acid (UA) removed during dialysis by two algorithms based on UV-absorbance and the 1st derivate of UV absorbance. Ten uremic patients from Tallinn and ten from Linkoumlping, during 30+40 haemodialysis treatments, were followed at the Departments of Dialysis and Nephrology at North-Estonian Medical Centre and at Linkoumlping University Hospital. The dialysate samples were taken and analyzed by means of UA concentration at the chemical laboratory and with a double-beam spectrophotometer. UV absorbance and derivate of UV absorbance was transformed into UA concentration in the spent dialysate using the regression models from the calibration set of material, noted as UV-absorbance (UV_A) and the 1st derivate of UV absorbance (UV_D) method. These models were tested on validation set of material and concentrations of UA from the two methods were compared regarding mean values and SD. Mean concentration of UA were 52.7 plusmn 25.0 micromol/l measured at the chemical laboratory (UA_Lab), 54.9 plusmn 23.8 micromol/l determined by UV_A and 52.9 plusmn 23.0 micromol/l determined by UV_D. The results of mean concentrations were not significantly different (p ges 0.54). The systematic errors were -7.8 % and -3.3% and random errors were 15.8 % and 10.4 % using UV_A and UV_D respectively. The systematic and random errors were significantly different (p < 0.05) indicating that the new algorithm enables more accurate UA estimation.

1 January 2008 in IFMBE Proceedings
Verified
Book Chapter
Closed access
PDF file
JHJana Holmar
Jana Holmar
FUF. Uhlin
F. Uhlin
IFIvo Fridolin
Ivo Fridolin

1 August 2006
Verified
Conference Paper
Closed access
KLKai Lauri
Kai Lauri
RTRisto Tanner
Risto Tanner
MLMerike Luman
Merike Luman
JHJana Holmar
Jana Holmar
IFIvo Fridolin
Ivo Fridolin
Several on-line methods have been developed to standardize the assessment of dialysis adequacy. Earlier studies have demonstrated that on-line monitoring of total ultra violet (UV) absorbance in spent dialysate can be utilized to follow continuously a single hemodialysis session. The aim of this study was to investigate the contribution of different compounds, acting as chromophores, to the UV-absorbance in the spent dialysate in order to explain origin of the cumulative and integrated UV-absorbance measured by the optical dialysis adequacy sensor. Four uremic patients, during 12 hemodialysis treatments, were followed by the optical dialysis adequacy sensor using the wavelength of 280 mn. The dialysate samples were taken and analyzed using reversed phase high performance liquid chromatography (HPLC). The total number of detected peaks from the HPLC gradient separation profiles measured at the wavelength 280 nm for the samples collected 10 mm after the start of hemodialysis (MeanplusmnSD) was 38plusmn6. The relative contribution from the area of 10 main peaks to the total area of all detected peaks in percentage was 91.01plusmn2.52 %. The optical dialysis adequacy sensor provides continuous, on-line hemodialysis measurements and may immediately identify and alert to any deviations in the dialysis. Our study indicates that there exists a number of prevalent compounds that are the main cause of the cumulative and integrated UV- absorbance