Murat Selek

Prof. Murat Selek

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011 in International Journal of Refrigeration
Verified
Journal Article
Closed access
MSMurat Selek
Murat Selek
STS. Tasdemir
S. Tasdemir
KDK. Dincer
K. Dincer
SBS. Baskaya
S. Baskaya

15 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SÖSerkan Örücü
Serkan Örücü
MSMurat Selek
Murat Selek
In sports and rehabilitation processes where isotonic movements such as bodybuilding are performed, it is vital for individuals to be able to correct the wrong movements instantly by monitoring the trainings simultaneously, and to be able to train healthily and away from the risks of injury. For this purpose, we designed a new real-time athlete support system using Kinect V2 and Expert System. Lateral raise (LR) and dumbbell shoulder press (DSP) movements were selected as examples to be modeled in the system. Kinect V2 was used to obtain angle and distance changes in the shoulder, elbow, wrist, hip, knee, and ankle during movements in these movement models designed. For the rule base of Expert System developed according to these models, a 28-state rule table was designed, and 12 main rules were determined that could be used for both actions. In the sample trainings, it was observed that the decisions made by the system had 89% accuracy in DSP training and 82% accuracy in LR training. In addition, the developed system has been tested by 10 participants (25.8 ± 5.47 years; 74.69 ± 14.81 kg; 173.5 ± 9.52 cm) in DSP and LR training for four weeks. At the end of this period and according to the results of paired t-test analysis (p < 0.05) starting from the first week, it was observed that the participants trained more accurately and that they enhanced their motions by 58.08 ± 11.32% in LR training and 54.84 ± 12.72% in DSP training.

9 September 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
SÖSerkan Örücü
Serkan Örücü
MSMurat Selek
Murat Selek
Monitoring of training performance and physical activity has become indispensable these days for athletes. Wireless technologies have started to be widely used in the monitoring of muscle activation, in the sport performance of athletes, and in the examination of training efficiency. The monitorability of performance simultaneously in the process of training is especially a necessity for athletes at the beginner level to carry out healthy training in sports like weightlifting and bodybuilding. For this purpose, a new system consisting of 4 channel wireless wearable SEMG circuit and analysis software has been proposed to detect dynamic muscle contractions and to be used in real-time training performance monitoring and analysis. The analysis software, the Haar wavelet filter with threshold cutting, can provide performance analysis by using the methods of moving RMS and %MVC. The validity of the data obtained from the system was investigated and compared with a biomedical system. In this comparison, 90.95% ± 3.35 for left biceps brachii (BB) and 90.75% ± 3.75 for right BB were obtained. The output of the power and %MVC analysis of the system was tested during the training of the participants at the gym, and the training efficiency was measured as 96.87% ± 2.74.

3 May 2013 in Acta Odontologica Scandinavica
Verified
Journal Article
Closed access
PDF file
SASertac Aksakalli
Sertac Aksakalli
ADAbdullah Demir
Abdullah Demir
MSMurat Selek
Murat Selek
STSakir Tasdemir
Sakir Tasdemir
Aim. To evaluate the effects of different curing units and light-tip tooth surface distances on the temperature increase generated during orthodontic bonding, using an infrared camera (IR) and artificial neural networks (ANN). Materials and methods. Fifty-two freshly extracted human premolar teeth were used. Metallic orthodontic brackets were bonded to the buccal surfaces of the teeth and thermal records were taken using an IR camera and ANN. Brackets were cured with a light-emitting diode (LED) and high intensity halogen (HQTH). Teeth were divided into four groups according to the curing units (LED and HQTH) and curing distances (from tooth surface and 10 mm away from tooth surface). The results were analyzed with analysis of variance (ANOVA) and the Tukey HSD test. Results. The ANOVA and Tukey HSD tests revealed that temperature changes were influenced by the type of light source and exposure times. All groups revealed significant differences between each other (p < 0.001). The highest surface temperature increase was gained from curing with a LED unit from the tooth surface (11.35°C ± 0.91°C). The lowest surface temperature increase was gained from curing with a HQTH unit 10 mm away from the tooth surface (2.57°C ± 0.6°C). Conclusion. The LED unit induced significantly higher temperature changes than did the HQTH. The temperature increase during orthodontic bonding was increased with long exposure time. A shorter light-tip tooth surface distance leads to greater increases in temperature.

16 February 2020 in Computer Applications in Engineering Education
Verified
Journal Article
Closed access
PDF file
MSMurat Selek
Murat Selek
YKYunus E. Kıymaz
Yunus E. Kıymaz

1 May 2009 in Expert Systems with Applications
Verified
Journal Article
Closed access
MSMurat Selek
Murat Selek
ÖŞÖmer Sinan Şahin
Ömer Sinan Şahin
ŞKŞirzat Kahramanli
Şirzat Kahramanli