Serkan Örücü

Mr. Serkan Örücü

Vocational School of Technical Sciences, Karamanoğlu Mehmetbey University, Karaman, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SÖSerkan Örücü
Serkan Örücü
MSMurat Selek
Murat Selek
In sports and rehabilitation processes where isotonic movements such as bodybuilding are performed, it is vital for individuals to be able to correct the wrong movements instantly by monitoring the trainings simultaneously, and to be able to train healthily and away from the risks of injury. For this purpose, we designed a new real-time athlete support system using Kinect V2 and Expert System. Lateral raise (LR) and dumbbell shoulder press (DSP) movements were selected as examples to be modeled in the system. Kinect V2 was used to obtain angle and distance changes in the shoulder, elbow, wrist, hip, knee, and ankle during movements in these movement models designed. For the rule base of Expert System developed according to these models, a 28-state rule table was designed, and 12 main rules were determined that could be used for both actions. In the sample trainings, it was observed that the decisions made by the system had 89% accuracy in DSP training and 82% accuracy in LR training. In addition, the developed system has been tested by 10 participants (25.8 ± 5.47 years; 74.69 ± 14.81 kg; 173.5 ± 9.52 cm) in DSP and LR training for four weeks. At the end of this period and according to the results of paired t-test analysis (p < 0.05) starting from the first week, it was observed that the participants trained more accurately and that they enhanced their motions by 58.08 ± 11.32% in LR training and 54.84 ± 12.72% in DSP training.

9 September 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
SÖSerkan Örücü
Serkan Örücü
MSMurat Selek
Murat Selek
Monitoring of training performance and physical activity has become indispensable these days for athletes. Wireless technologies have started to be widely used in the monitoring of muscle activation, in the sport performance of athletes, and in the examination of training efficiency. The monitorability of performance simultaneously in the process of training is especially a necessity for athletes at the beginner level to carry out healthy training in sports like weightlifting and bodybuilding. For this purpose, a new system consisting of 4 channel wireless wearable SEMG circuit and analysis software has been proposed to detect dynamic muscle contractions and to be used in real-time training performance monitoring and analysis. The analysis software, the Haar wavelet filter with threshold cutting, can provide performance analysis by using the methods of moving RMS and %MVC. The validity of the data obtained from the system was investigated and compared with a biomedical system. In this comparison, 90.95% ± 3.35 for left biceps brachii (BB) and 90.75% ± 3.75 for right BB were obtained. The output of the power and %MVC analysis of the system was tested during the training of the participants at the gym, and the training efficiency was measured as 96.87% ± 2.74.

16 May 2025 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
BIBulent Isik
Bulent Isik
KEKenan Erdağı
Kenan Erdağı
SÖSerkan Örücü
Serkan Örücü
UOUsame Omer Osmanoglu
Usame Omer Osmanoglu
EÖErkan ÖZBAY
Erkan ÖZBAY
Anthropometric measurements are important in a wide range of areas, from athlete selection to performance analysis and medical exercise applications. With its portable and cost-effective structure, Microsoft Kinect offers significant advantages in measuring human movements and provides valuable data in the fields of sports science and medicine. The aim of this study is to compare certain anthropometric measurements of adolescent female weightlifters in the U-15 age category with Kinect V2 and traditional methods. Twelve athletes who won medals in international weightlifting championships were included in the study. Anthropometric evaluations of each athlete were performed using Kinect V2 and the traditional method. Differences between measurements were analyzed with Bland–Altman plots and Pearson correlation coefficients. Kinect was found to exhibit less variability and higher coherency in measurements of humerus, forearm, trochanter-tibiale laterale, tibial lengths, and shoulder width. It has been observed that the traditional method provides more coherence results in hand length measurements. Kinect was found to exhibit less variability and higher coherency in measurements of forearm, trochanter-tibiale laterale, tibial lengths, and shoulder width, indicating its potential as a reliable tool for these parameters. Notably, Kinect demonstrated high reliability for tibial length (ICC 0.918) and moderate reliability for trochanter-tibiale laterale (ICC 0.737), showing its effectiveness in these measurements. Additionally, Kinect exhibited lower variation and higher coherency in most measurements compared to manual methods, supporting its consistency and repeatability in anthropometric assessments. These results indicate that Kinect may be a suitable tool for some measurements but that traditional methods may be preferable for hand length measurements. These findings suggest that Kinect can be used effectively for certain anthropometric measurements in sports and medical science. Graphical Abstract

9 April 2025 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
SÖSerkan Örücü
Serkan Örücü
BIBulent Isik
Bulent Isik
KEKenan Erdağı
Kenan Erdağı
UOUsame Omer Osmanoglu
Usame Omer Osmanoglu
EÖErkan ÖZBAY
Erkan ÖZBAY
The importance of anthropometric measurements for monitoring the physical development of athletes and optimizing training programs is well known. Considering the limitations of traditional methods in terms of accuracy and consistency, the aim of this study is to investigate the potential of Kinect V2 as an alternative. This study wasperformed on 12 youth female weightlifters who won medals in the Youth European Weightlifting Championship. Humerus length, forearm length, hand length, trochanter-tibiale laterale length, tibial length and shoulder width measurements were performed with both Kinect V2 and manual methods. Statistical differences between groups were evaluated using the Mann–Whitney U test. The consistencies of the measurement methods were analyzed with Bland-Altman plots, correlations were determined with Pearson correlation coefficients, and reliability were evaluated with Intraclass Correlation Coefficient (ICC) values. Kinect V2 provided accuracy and consistency comparable to manual methods in measurements of humerus (ICC = 0.532), forearm (ICC = 0.600), and hand length (ICC = 0.760). While medium-level concordance was observed in trochanter-tibiale lateral length measurements (ICC = 0.749), high-level concordance and reliability were found in tibial length (ICC = 0.914) and shoulder width (ICC = 0.869) measurements. There were significant differences between the results of humerus length, forearm length and trochanter-tibiale laterale length obtained with both measurement methods. Therefore, measurements of these parameters require significant care. Findings of this study suggest that Kinect V2 can be a reliable tool for rapid and practical anthropometric assessments in sports settings, but highlight the importance of careful calibration and adjustments for specific measurements. Future studies should examine the use of this device more comprehensively across different sports and populations. Anthropometric measurements are important for monitoring the physical development of athletes and optimizing their training programs. Considering the limitations of traditional methods in terms of accuracy and consistency. Kinect analyzes the movements of athletes during sports education and training processes, making it possible to organize training programs according to individual needs. Kinect V2, which has a high potential for use, especially in medical exercise and clinical applications, also finds a wide range of applications in sports sciences. In this study, a comparative analysis of certain lower and upper extremity anthropometric measurements such as humerus length, forearm length, hand length, trochanter-tibiale laterale length, tibial length and shoulder width of female weightlifting athletes in the youth age category were performed using Kinect V2 and manual methods.

9 July 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
UOUsame Omer Osmanoglu
Usame Omer Osmanoglu
KEKenan Erdağı
Kenan Erdağı
BIBulent Isik
Bulent Isik
SÖSerkan Örücü
Serkan Örücü
EÖErkan ÖZBAY
Erkan ÖZBAY
Microsoft Kinect is an increasingly common tool for low-cost and portable measurement of human movements. The aim of this study was to investigate the potential reliability and reproducibility of Microsoft Kinect Azure in the sit-and-reach test conducted under standardized test conditions in a controlled training environment with elite female weightlifters. The sit-and-reach test was performed with Microsoft Kinect Azure and manual methods and also the reliability and validity were analyzed by comparing the wrist, elbow, shoulder and trunk joint angle measurements with the digital goniometer. Twenty-one healthy female weightlifter athletes who won medals in international championships were included in the study. Sit-and-reach testing was performed using Microsoft Kinect Azure and manual methods in accordance with the standards of the American College of Sports Medicine. The flexion range of motions of each athlete’s wrist, elbow, shoulder and trunk joint angles were measured with a digital goniometer and Microsoft Kinect Azure. Statistical analyses were performed using IBM SPSS 25.0 and Python 3.9.12 software. Descriptive statistics were calculated for all variables, and differences between Kinect and manual methods were evaluated with the Mann-Whitney U test and Wilcoxon Signed-Rank Test. Linear relationships between measurements were analyzed with Spearman correlation coefficients. Intraclass Correlation Coefficient was calculated for the concordance analysis and presented with Bland-Altman plots. The level of significance was accepted as p < 0.05. The findings suggest that Kinect Azure may provide good reproducibility and agreement with manual goniometric measurements for joint angles under the specific structured conditions tested. For parameters such as the elbow, shoulder, wrist, trunk angles and distance traveled, high ICC values (> 0.90) indicated strong consistency between the methods. Kinect Azure may serve as a reliable alternative to manual measurement methods under standardized testing conditions. Further studies are recommended to examine its generalizability to other populations and test environments.

6 May 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BIBulent Isik
Bulent Isik
KEKenan Erdağı
Kenan Erdağı
SÖSerkan Örücü
Serkan Örücü
EÖErkan ÖZBAY
Erkan ÖZBAY
UOUsame Omer Osmanoglu
Usame Omer Osmanoglu
Accurate assessment of joint range of motion (ROM) is essential in both clinical and athletic contexts for monitoring mobility, guiding rehabilitation, and optimizing performance. Traditional tools such as goniometers are widely used but limited by operator dependency and static measurement constraints. Depth-sensing technologies offer a markerless alternative that may enhance practicality in field-based settings. This study examined the validity and reliability of the Microsoft Azure Kinect system compared with a digital goniometer for assessing hip and knee ROM in 30 elite female weightlifters from the Turkish National Team. Participants performed hip abduction, adduction, flexion, extension, and knee flexion, each measured using both tools. Agreement between systems was assessed using Pearson’s correlations, intraclass correlation coefficients [ICC (3,1)], and Bland-Altman analyses. No significant differences were found between methods (p > 0.05), with strong correlations (r = 0.974–0.997) and high intraclass correlation coefficients (ICC = 0.994–0.998), indicating excellent consistency. Bland-Altman analyses showed minimal bias and narrow limits of agreement. These findings support the Azure Kinect as a valid and reliable tool for lower-extremity ROM assessment and a viable alternative to traditional goniometers in field applications.