Modern pumps are designed to guarantee a sufficiently large operating range or to satisfy the performance requirements relative to more than one operating point. This study applies trailing-edge (TE) modification method based on TE rounding in the suction surface to widen the operating range of a mixed-flow pump. The effects of TE modification on the performance and internal flow of the mixed-flow pump are investigated through computational fluid dynamics (CFD) analysis. Local Euler head distribution is introduced to reveal the pattern of energy growth along the blade-aligned (BA) streamwise location. A pump model with TE modification is tested, and numerical results agree well with experimental data. The results show that TE modification significantly improves pump efficiency in the high flow rate region by more than 10%. The best pattern of normalized local Euler head distribution (NLEHD) is a convex curve of nearly constant growth rate. The overall heads are also improved, and the flow near the exit of the impeller exhibits better uniformity. This finding demonstrates that a small change in the TE of the impeller can influence flow structure in most areas of impeller channels and that the local Euler head distribution is closely related to pump efficiency. TE modification can effectively improve the performance of the mixed-flow pump with high flow rate.
In order to study the effects of the suction and discharge conditions on the hydraulic performance and unsteady flow phenomena of an axial-flow reactor coolant pump (RCP), three RCP models with different suction and discharge configurations are analyzed by computational fluid dynamics (CFD) method. The CFD results are validated by experimental data. The hydraulic performance of the three RCP models shows little difference. However, the unsteady flow phenomena of RCP are significantly affected by the variation of suction and discharge conditions. Compared with that of Model E-S (baseline, elbow-single nozzle), the pressure pulsation in rotating frame of Model S-S (straight pipe-single nozzle) and Model E-D (elbow-double nozzles) is weakened in different degrees and forms, due to the more uniform flow fields upstream and downstream of the impeller, respectively. It indicates that the generalized rotor-stator interaction (RSI) actually exists between the rotating impeller and all stationary components causing the circumferentially non-uniform flow. Furthermore, improving the circumferential uniformity of the flow upstream and downstream of impeller (suction and discharge flow) also contributes to reducing the radial dynamic fluid force acting on the impeller. Compared with those of Model E-S, the dynamic FX and FY of Model S-S are severely weakened, and those of Model E-D also gain a minor amplitude decrease at fBPF. In contrast, the general pressure pulsation in fixed frame is mainly related to the rotating impeller and barely affected by the suction and discharge conditions.