Michael Paulsen

Michael Paulsen

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2017 in Science Advances
Verified
Journal Article
Open access
PDF file
JCJeffrey E. Cohen
Jeffrey E. Cohen
AGAndrew B. Goldstone
Andrew B. Goldstone
MPMichael Paulsen
Michael Paulsen
YSYasuhiro Shudo
Yasuhiro Shudo
ASAmanda N. Steele
Amanda N. Steele
YWY. Joseph Woo
Y. Joseph Woo
Coronary artery disease is one of the most common causes of death and disability, afflicting more than 15 million Americans. Although pharmacological advances and revascularization techniques have decreased mortality, many survivors will eventually succumb to heart failure secondary to the residual microvascular perfusion deficit that remains after revascularization. We present a novel system that rescues the myocardium from acute ischemia, using photosynthesis through intramyocardial delivery of the cyanobacterium Synechococcus elongatus. By using light rather than blood flow as a source of energy, photosynthetic therapy increases tissue oxygenation, maintains myocardial metabolism, and yields durable improvements in cardiac function during and after induction of ischemia. By circumventing blood flow entirely to provide tissue with oxygen and nutrients, this system has the potential to create a paradigm shift in the way ischemic heart disease is treated.

1 March 2018 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
AIArnar B. Ingason
Arnar B. Ingason
AGAndrew B. Goldstone
Andrew B. Goldstone
MPMichael Paulsen
Michael Paulsen
ATAkshara D. Thakore
Akshara D. Thakore
VTVi N. Truong
Vi N. Truong
YWY. Joseph Woo
Y. Joseph Woo

16 January 2020 in Cells
Verified
Journal Article
Open access
PDF file
HWHanjay Wang
Hanjay Wang
MPMichael Paulsen
Michael Paulsen
CHCamille E. Hironaka
Camille E. Hironaka
HSHye Sook Shin
Hye Sook Shin
JFJustin M. Farry
Justin M. Farry
YWY. Joseph Woo
Y. Joseph Woo
Newborn mice and piglets exhibit natural heart regeneration after myocardial infarction (MI). Discovering other mammals with this ability would provide evidence that neonatal cardiac regeneration after MI may be a conserved phenotype, which if activated in adults could open new options for treating ischemic cardiomyopathy in humans. Here, we hypothesized that newborn rats undergo natural heart regeneration after MI. Using a neonatal rat MI model, we performed left anterior descending coronary artery ligation or sham surgery in one-day-old rats under hypothermic circulatory arrest (n = 74). Operative survival was 97.3%. At 1 day post-surgery, rats in the MI group exhibited significantly reduced ejection fraction (EF) compared to shams (87.1% vs. 53.0%, p < 0.0001). At 3 weeks post-surgery, rats in the sham and MI groups demonstrated no difference in EF (71.1% vs. 69.2%, respectively, p = 0.2511), left ventricular wall thickness (p = 0.9458), or chamber diameter (p = 0.7801). Masson’s trichome and picrosirius red staining revealed minimal collagen scar after MI. Increased numbers of cardiomyocytes positive for 5-ethynyl-2′-deoxyuridine (p = 0.0072), Ki-67 (p = 0.0340), and aurora B kinase (p = 0.0430) were observed within the peri-infarct region after MI, indicating ischemia-induced cardiomyocyte proliferation. Overall, we present a neonatal rat MI model and demonstrate that newborn rats are capable of endogenous neocardiomyogenesis after MI.

1 August 2019 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Open access
MPMichael Paulsen
Michael Paulsen
PKPatpilai Kasinpila
Patpilai Kasinpila
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
HWHanjay Wang
Hanjay Wang
CHCamille E. Hironaka
Camille E. Hironaka
YWY. Joseph Woo
Y. Joseph Woo
The optimal conduit for valve-sparing aortic root replacement is still debated, with several conduit variations available, ranging from straight tubular grafts to Valsalva grafts. Benefits of neosinus reconstruction include enhanced flow profiles and improved hemodynamics. Curiously, however, some clinical data suggest that straight grafts may have greater long-term durability. In this study, we hypothesized that straight tubular grafts may help maintain the native cylindrical position of the aortic valve commissures radially, resulting in preserved leaflet coaptation, reduced stresses, and potentially improved valve performance. Using 3D printing, a left heart simulator with a valve-sparing root replacement model and a physiologic coronary circulation was constructed. Aortic valves were dissected from fresh porcine hearts and reimplanted into either straight tubular grafts (n = 6) or Valsalva grafts (n = 6). Conduits were mounted into the heart simulator and hemodynamic, echocardiographic, and high-speed videometric data were collected. Hemodynamic parameters and coronary blood flow were similar between straight and Valsalva grafts, although the former were associated with lower regurgitant fractions, less peak intercommissural radial separation, preserved leaflet coaptation, decreased leaflet velocities, and lower relative leaflet forces compared with Valsalva grafts. Valsalva grafts and straight grafts perform equally well in terms of gross hemodyanics and coronary blood flow. Interestingly, however, the biomechanics of these 2 conduits differ considerably, with straight grafts providing increased radial commissural stability and leaflet coaptation. Further investigation into how these parameters influence clinical outcomes is warranted.

6 November 2018 in Circulation
Verified
Journal Article
Closed access
DBDaniel von Bornstädt
Daniel von Bornstädt
HWHanjay Wang
Hanjay Wang
MPMichael Paulsen
Michael Paulsen
AGAndrew B. Goldstone
Andrew B. Goldstone
AEAnahita Eskandari
Anahita Eskandari
YWY. Joseph Woo
Y. Joseph Woo
Background: Cardiovascular bypass grafting is an essential treatment for complex cases of atherosclerotic disease. Because the availability of autologous arterial and venous conduits is patient-limited, self-assembled cell-only grafts have been developed to serve as functional conduits with off-the-shelf availability. The unacceptably long production time required to generate these conduits, however, currently limits their clinical utility. Here, we introduce a novel technique to significantly accelerate the production process of self-assembled engineered vascular conduits. Methods: Human aortic smooth muscle cells and skin fibroblasts were used to construct bilevel cell sheets. Cell sheets were wrapped around a 22.5-gauge Angiocath needle to form tubular vessel constructs. A thin, flexible membrane of clinically approved biodegradable tissue glue (Dermabond Advanced) served as a temporary, external scaffold, allowing immediate perfusion and endothelialization of the vessel construct in a bioreactor. Subsequently, the matured vascular conduits were used as femoral artery interposition grafts in rats (n=20). Burst pressure, vasoreactivity, flow dynamics, perfusion, graft patency, and histological structure were assessed. Results: Compared with engineered vascular conduits formed without external stabilization, glue membrane–stabilized conduits reached maturity in the bioreactor in one-fifth the time. After only 2 weeks of perfusion, the matured conduits exhibited flow dynamics similar to that of control arteries, as well as physiological responses to vasoconstricting and vasodilating drugs. The matured conduits had burst pressures exceeding 500 mm Hg and had sufficient mechanical stability for surgical anastomoses. The patency rate of implanted conduits at 8 weeks was 100%, with flow rate and hind-limb perfusion similar to those of sham controls. Grafts explanted after 8 weeks showed a histological structure resembling that of typical arteries, including intima, media, adventitia, and internal and external elastic membrane layers. Conclusions: Our technique reduces the production time of self-assembled, cell sheet–derived engineered vascular conduits to 2 weeks, thereby permitting their use as bypass grafts within the clinical time window for elective cardiovascular surgery. Furthermore, our method uses only clinically approved materials and can be adapted to various cell sources, simplifying the path toward future clinical translation.

1 October 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
MPMichael Paulsen
Michael Paulsen
JBJung Hwa Bae
Jung Hwa Bae
AIAnnabel Imbrie-Moore
Annabel Imbrie-Moore
HWHanjay Wang
Hanjay Wang
CHCamille E. Hironaka
Camille E. Hironaka
YWY. Joseph Woo
Y. Joseph Woo
Few technologies exist that can provide quantitative data on forces within the mitral valve apparatus. Marker-based strain measurements can be performed, but chordal geometry and restricted optical access are limitations. Foil-based strain sensors have been described and work well, but the sensor footprint limits the number of chordae that can be measured. We instead utilized fiber Bragg grating (FBG) sensors—optical strain gauges made of 125 μm diameter silica fibers—to overcome some limitations of previous methods of measuring chordae tendineae forces. Using FBG sensors, we created a force-sensing neochord (FSN) that mimics the natural shape and movement of native chordae. FBG sensors reflect a specific wavelength of light depending on the spatial period of gratings. When force is applied, the gratings move relative to one another, shifting the wavelength of reflected light. This shift is directly proportional to force applied. The FBG sensors were housed in a protective sheath fashioned from a 0.025 in. flat coil, and attached to the chordae using polytetrafluoroethylene suture. The function of the force-sensing neochordae was validated in a three-dimensional (3D)-printed left heart simulator, which demonstrated that FBG sensors provide highly sensitive force measurements of mitral valve chordae at a temporal resolution of 1000 Hz. As ventricular pressures increased, such as in hypertension, chordae forces also increased. Overall, FBG sensors are a viable, durable, and high-fidelity sensing technology that can be effectively used to measure mitral valve chordae forces and overcome some limitations of other such technologies.