Andreas Kiontke

Dr. Andreas Kiontke

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AKAndreas Kiontke
Andreas Kiontke
AOAriana Oliveira-Birkmeier
Ariana Oliveira-Birkmeier
AOAndreas Optiz
Andreas Optiz
CWClaudia Wiesner
Claudia Wiesner
Over the past decades, electrospray ionization for mass spectrometry (ESI-MS) has become one of the most commonly employed techniques in analytical chemistry, mainly due to its broad applicability to polar and semipolar compounds and the superior selectivity which is achieved in combination with high resolution separation techniques. However, responsiveness of an analytical method also determines its suitability for the quantitation of chemical compounds; and in electrospray ionization for mass spectrometry, it can vary significantly among different analytes with identical solution concentrations. Therefore, we investigated the ESI-response behavior of 56 nitrogen-containing compounds including aromatic amines and pyridines, two compound classes of high importance to both, synthetic organic chemistry as well as to pharmaceutical sciences. These compounds are increasingly analyzed employing ESI mass spectrometry detection due to their polar, basic character. Signal intensities of the peaks from the protonated molecular ion (MH+) were acquired under different conditions and related to compound properties such as basicity, polarity, volatility and molecular size exploring their quantitative impact on ionization efficiency. As a result, we found that though solution basicity of a compound is the main factor initially determining the ESI response of the protonated molecular ion, other factors such as polarity and vaporability become more important under acidic solvent conditions and may nearly outweigh the importance of basicity under these conditions. Moreover, we show that different molecular descriptors may become important when using different types of instruments for such investigations, a fact not detailed so far in the available literature.

27 April 2012 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
AHAntje Hutschenreuther
Antje Hutschenreuther
AKAndreas Kiontke
Andreas Kiontke
GBGerd Birkenmeier
Gerd Birkenmeier
CWClaudia Wiesner
Claudia Wiesner
Common extraction protocols and sampling procedures for GC-MS metabolite profiling were applied to the MCF-7 breast cancer cell culture as a model system of adherent growing cells and validated for repeatability and reproducibility. For normalization of a concentration series after methanolic extraction, results obtained with cell count normalization equalled normalization to the chromatogram total ion current as a chromatogram-intrinsic parameter, indicating that cell counting as an additional experimental step could be omitted. However, we show here that both normalization strategies should only be applied for comparison of extracts with similar concentrations complicating comparisons of different samples, e.g. with different biological origin. Therefore, the application of TIC thresholds for the comparison of differently concentrated extracts is recommended with respect to the accuracy of the data, the working effort and complexity of the biological experiment. For proof of concept, MCF-7 cell samples generated by different sampling procedures were assessed using these thresholds. Within this context, direct extraction of adherent growing cells without any further preparation steps, which allows for rapid quenching of cell metabolism and efficient sample extraction, is discussed as an alternative to conventional cell counting and extraction. In conclusion, we recommend the consideration of chromatogram intensity thresholds for the mean comparison of differently concentrated sample replicates in GC-MS metabolite profiling.

1 June 2012 in European Journal of Mass Spectrometry
Verified
Journal Article
Closed access
RARamarao Abburi
Ramarao Abburi
Stefan KalkhofStefan Kalkhof
Stefan Kalkhof
RORamona Oehme
Ramona Oehme
AKAndreas Kiontke
Andreas Kiontke
CWClaudia Wiesner
Claudia Wiesner
Different phenylenediamines were used to explore anodic oxidation in solution during electrospray ionization (ESI) mass spectrometry analysis. In our experiments, a series of unknown ionic species was detected in the phenylenediamine solutions. Our results propose that reactions of phenylenediamines with species formed by anodic oxidation of typical ESI solvents during the electrospray ionization process such as formaldehyde are producing these peaks. Identification of these compounds inter alia suggests formal alkylation, a reaction not reported so far as a result of electrolytic oxidation in the prospective organic solvents.

13 April 2018 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
AKAndreas Kiontke
Andreas Kiontke
FHFrank Holzer
Frank Holzer
DBDetlev Belder
Detlev Belder
CWClaudia Wiesner
Claudia Wiesner

3 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAndreas Kiontke
Andreas Kiontke
MRMehrzad Roudini
Mehrzad Roudini
SBSusan Billig
Susan Billig
AFArmaghan Fakhfouri
Armaghan Fakhfouri
AWAndreas Winkler
Andreas Winkler
CWClaudia Wiesner
Claudia Wiesner
Mass spectrometry coupled to low-temperature plasma ionization (LTPI) allows for immediate and easy analysis of compounds from the surface of a sample at ambient conditions. The efficiency of this process, however, strongly depends on the successful desorption of the analyte from the surface to the gas phase. Whilst conventional sample heating can improve analyte desorption, heating is not desirable with respect to the stability of thermally labile analytes. In this study using aromatic amines as model compounds, we demonstrate that (1) surface acoustic wave nebulization (SAWN) can significantly improve compound desorption for LTPI without heating the sample. Furthermore, (2) SAWN-assisted LTPI shows a response enhancement up to a factor of 8 for polar compounds such as aminophenols and phenylenediamines suggesting a paradigm shift in the ionization mechanism. Additional assets of the new technique demonstrated here are (3) a reduced analyte selectivity (the interquartile range of the response decreased by a factor of 7)—a significant benefit in non-targeted analysis of complex samples—and (4) the possibility for automated online monitoring using an autosampler. Finally, (5) the small size of the microfluidic SAWN-chip enables the implementation of the method into miniaturized, mobile LTPI probes.

18 December 2018 in International Journal of Analytical Chemistry
Verified
Journal Article
Open access
PDF file
AKAndreas Kiontke
Andreas Kiontke
SBSusan Billig
Susan Billig
CWClaudia Wiesner
Claudia Wiesner
Modern technical evolution made mass spectrometry (MS) an absolute must for analytical chemistry in terms of application range, detection limits and speed. When it comes to mass spectrometric detection, one of the critical steps is to ionize the analyte and bring it into the gas phase. Several ionization techniques were developed for this purpose among which electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are two of the most frequently applied atmospheric pressure methods to ionize target compounds from liquid matrices or solutions. Moreover, recent efforts in the emerging field of “ambient” MS enable the applicability of newly developed atmospheric pressure techniques to solid matrices, greatly simplifying the analysis of samples with MS and anticipating, to ease the required or even leave out any sample preparation and enable analysis at ambient conditions, outside the instrument itself. These developments greatly extend the range of applications of modern mass spectrometry (MS). Ambient methods comprise many techniques; a particular prominent group is, however, the plasma-based methods. Although ambient MS is a rather new field of research, the interest in further developing the corresponding techniques and enhancing their performance is very strong due to their simplicity and often low cost of manufacturing. A precondition for improving the performance of such ion sources is a profound understanding how ionization works and which parameters determine signal response. Therefore, we review relevant compound characteristics for ionization with the two traditional methods ESI and APCI and compare those with one of the most frequently employed representatives of the plasma-based methods, i.e., low temperature plasma ionization. We present a detailed analysis in which compound characteristics are most beneficial for the response of aromatic nitrogen-containing compounds with these three methods and provide evidence that desorption characteristics appear to have the main common, general impact on signal response. In conclusion, our report provides a very useful resource to the optimization of instrumental conditions with respect to most important requirements of the three ionization techniques and, at the same time, for future developments in the field of ambient ionization.